Loading...
HomeMy WebLinkAboutPlans - 171 BRENTWOOD CIRCLE 9/25/2012 MIRAFI 1OOX SEDIMENTATION CONTROL FABRIC 1 ,•.,'c�� OArIACHED X 2' WOODEN POST LEGEND EXISTING CONTOUR --- -- •� PROPOSED FINISH CONTOUR PROPOSED MATER LINE ry MOUND CHAIN LINK FENCE —v—v— � SILT FENCE F \. SOIL AGAINST EXISTING WATER LINE '..F FENCE TOP FOUND.ELEVATION T.F.=100 , FIRST FLOOR ELEVATION F.F.=100 I \�• ```•y GROUND GARAGE FLOOR ELEVATION G.F.=100 EXISTING LEVEL SPOT FINISH ELEVATION 100.00GROUND " 0 FLOW EXISTING TREE LINE EXISTING TREE TO BE REMOVED GROUND zI 2 X 2" LEVEL ° STOCKPILE AREA LOCUS (BEHIND) n POST 4'-0° iv iv AIAXIMUM m OBSERVATION WELL •OW SILTATION CONTROL FENCE DETAIL NOT TO SCALE WETLAND BOUNDARY-\_ >..may}= T-y, ST27000/ . an o 66 e t!)b 78 eb �/ r- PROPOSED SILT�NCE/ \. _ 50 FT. NO DISTURB ZONE sb--/- _ kAR OF WORK �\ 4. MAP 64 75 Fr.NO BUILD ZONE e7`-_- / / -_- RRQPI ON 4 r ?z PARCEL 3 CHAIN LINK � 100 FT. BUFFER e\ J/ - CE i `` \ � ZONE/100'NON / / � \114 DISTURBANCE BOUNDARY WATERFALL ` — \ i/ a \ , I` 1).e° PROP. 1' X TRENCH 8 PROP. 1'X T.5'X 64' s�\- � � \ INFILTRATION TRENCH \ 7b/ I 1 I (SEE DETAIL) I (SEE DETAIL) 95 ROPP.._P o- 7. PROP. 1'X 1.5'X 8' \ go 8.04 INFILRATION(SEETDETAIL)TRENCH 9 \ ; .�. EC OK 7i7 \ \\ Esc EXISTING PAD.ROP 3 SLOPE DS 97.7 �9Z7\'• \ \ \( 1 I ` 1\\ RETAINING TRENCH 102' Ji_ PATIO\ \ \\\ \91`4 \ tov\/ MAP 64 0 ,y I PARCEL 41 /nh tz° MM _� y EXISTING TYO \ I � \ \ ( $171 50 FT.NO DISTURB ZONE !.. PROPOSED GENERATOR \\ / MAP \ 52 \ \ (PPROX.LOCATION) 1Q / PARCEL 42 \ \ \�\\\�\ 75 FT. NO BUILD ZONE ' 1 ; AREA-57.800 SFt \\94 a,t M�p� DO Fr. BUFFER ZONE/ 100' NON DISTURBANCE BOUNDARY � tw ___"_-------------------_-___`-- 3�0° BRENTWOOD CIRCLE (50 Fr. R.O.W. - PUBLIC) 500 % NOTES: 1.TITLE REFERENCE-BOOK 3490 PAGE 344 s _ 2.REFERENCE TOWN OF NORTH ANDOVER ASSESSORS MP 64 PARCEL 42 M b 60 eJ 3.MARCH DELINEATED BY NORSE ENVIRONMENTAL 61ARCH 2012 (IN E936r) 4.FENCE TO HAVE SELF-LATCHING,SELF-CLOSING 10-22-12 OP REVISE TRENCH DETAIL, ADD EQUIPMENT I Inch=40 IL GATES TO MEET ALL STATE AND LOCAL BUILDING PAD ADD GENERATOR CODES 10-11-12 OP REVISE NO DISTURB ZONE,CONSTRUCTION OTES TREES TO 5.THE LOCATION OF EXISTING UNDERGROUND N BE REMOVED JJ UTILITIES HAVE NOT BEEN FIELD VERIFIED.THE DAME BY REVISION 6"DIAMETER PERFORATED PVC CONTRACTOR SHALL VERIFY THEIR LOCATION OBSERVATION WELL WITH SCREW! PRIOR TO CONSTRUCTION,"DIG SAFE"SHALL BE TRENCH)(1 WELL IN EACH MASSACHUSETTS STATE LAW REQUIRES THREE 111 SWALE BUSINESS DAYS NOTICE PRIOR TO EXCAVATION. PROPOSED SWIMMING POOL -97.7 f 6.PRIOR TO CONSTRUCTION,ANY WORK WITHIN 171 BRENTWOOD CIRCLE 2" 1/8°-318°PEA STONE OF OOCONDITIONS PPROVEDRB REQUIRES AN ORDER NORTH ANDOVER, MA 01845 2" COPSE CONCRETE SAND CONSERVATION COMMISSION.THIS WORK HAS TO BE CONSTRUCTED IN COMPLIANCE WITH THE 6. 2"-6"WASHED STONE ORDER OF CONDITIONS. COARSE CONCRETE SAND Z CARTRIDGEPFILLTER BE EQUIPPED W1TH SCALE: 1 In. = 40 ft. DATE: SEPT. 25, 2012 2° 96.7 t 8.CONSTRUCTION VEHICLES SHALL USE THE EXISTING DRIVEWAY FOR ACCESS. '. 18" -ESHWT EL=93.6 f (AVG) Prepared For JM Associates INFILTRATION TRENCH Rose Sandoval 325 Main Street NOT TO SCALE JOBf671-477 171 Brentwood Circle No. Reading, MA 01864 SH. 1 OF 1 North Andover, Mo. 01845 978-664-6668 www.)massociateseng.com