Loading...
HomeMy WebLinkAboutBuilding Permit # 6/9/2015 IJIL I PERMIT FORTH qq-- �F'KLFp, rb�•W� TOWN OF NTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit No#: " Date Received d 'LiRp�mareo Pea q5 �SSACHUS�� Date Issued: IMPORTANT: Applicant musty complete all items on this page LOCATION 0,7)onax nl d/ Print PROPERTY OWNER 0-(-1 0 Print 100 Year Structure yes MAP l PARCEL: "�=ZONING DISTRICT:-" Historic District yes Machine Shop Village yes r I� TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family [IAddition ITwo or more f mily ❑ Industrial El Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other "::��r-,�, rr,,r . ,��/...,M�-x, , a::«.... ,,,r......,;iwt-, .. rradb +wr,fw ,lr il. riri✓, )f �12�rN p"�`�(� 1(NlJ;�1J.; .1�I✓r/1J11f.1/rl1Nf, /„ i�/r/%s tIC `s "JAI 'ayF Qpd JIt�r Wlatd ', Wt�C00 SCI' ,IStrlCtol'i; /` r . ,�" DESCRIPTION OF WORK TO BE PERFORMED: n o Cam Ide i icati - Pleas Type or Print Clearly OWNER: Name: " t r Phone: 3,St , q Address: 1'`v" 'v t l 10 Contractor ame: `w . Phone: �,'> 90 3" Email: " Address: ,(L, .v , C 151C Supervisor's Construction License:- CS 05q Exp. Date: 1 a 1 Home Improvement License: \� �] Exp. Date: 1 � ARCHITECT/ENGINEERnU',1l Phone: 00 3-1 Address: 1 - gig tilauo Reg. No. ' j lD–t— FEE SCHEDULE.BULDINC7 PERMIT:$92.00 PER$9000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: NOTE: Persons contracting with unr istered contractors do not have access to the uaranty fund �/Jy/�c,[!n r,J%'af��d!1/,%,�i7r/l� a.:r,r^' „^,r:r;,:.J r i17i-i-.,,,.. %///i 77""/ r!i,.r, roT/,"//"o—fi'i//./'✓,//Pf%,: re,/,i 4',¢. .i, „ „,1%// �r�/ .,��r�f�///�i/f///% i Plans Submitted ❑ Plans Waived ❑ Certified Plot Flan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑ well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑ Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ ................. THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF ® U FORM PLANNING & DEVELOPMENT Reviewed On Signature_ COMMENTS CONSERVATION Reviewed on L Si nature""' COMMENTS LI — � HEALTH Reviewed on Signature COMMENTS Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comment Fater& Sewer Connection/sil nature ID Driveway Permit ]DPW Town:Engineer: Signature: a "� ,- Located 384 Osgood Street IARdTI�IE ' FIRE DEP' r NST,„ Ternp Dum er on %` i�d4.,.%i(rl n„ n, �/�:1 rlrP„� � /!%Pll//KI/NA-1111111 Locd' at d of 12 e n 4 MainStreet F./.e ® , < , :; jir✓i /,!i /i ';/r / fi CQMMENi t%oRTH -Town ofE 1. ndover ® 0 ® h ver, Mass, 4CAX OLAKE A- COC KICKEWICK 9® RATED S u BOARD OF HEALTH Food/Kitchen PERMIT LD Septic System THIS CERTIFIES THAT . . ..,. ........ 1.04C .. ... .. BUILDING INSPECTOR has permission to erect .......... buildings on ...4Q;.(. .c gS Foundation ��� Rough tobe occupied as ....... r......� ...... �..\.. .. 1.1 ................................................. chimney provided that the person acce this er it shall in eve respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMITI IN 6 MONTHS ELECTRICAL INSPECTOR i� LESS CTI® R Rough Service .................... ... ....... ............................................ Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required t® Occupy Building Rough Islay in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. Smoke Det. t ; r ,. 014 LD IJ w , « G BLDG"0" � i c � ow?�. 7 CERTIFIED PLOT PLAN iNO OrHm um "roan MMUWY LOCI WD TS S*MW AK MWD ON T W== PLAM FM 'R" MKM TW rWMAnIN AS SHMM IMS NUT' VIAW MMW O"TE IMWDM & TO PMWRTY LTW 1 �OFT7" 4 f : m TKS M IS TO BE USCD TU -tCST , U Y Taw &TRUCTUXS, OR FCR LANDXWM MYKA -gg� T"ELY FtOdSWD BY AS9194,MAP&LOT ft THE M(WR TU TW F'Dft s E ROUTE 114, ¢NORTH ANDOVER, MASS, PROJECT t ND1 ALE, V=40' ` DRAWN BYt PCG DATEt 5/1/15 CHECKED BYtSC SHTt I VISM OFt I Scheck Software Version 4.6.1 C�(J Compliance Certificate Project 150527 Trust Merrimac_BIdgG_UnitG2_ModelB Energy Code: 2012 IECC Location: North Andover, Massachusetts Construction Type: Multi-family Project Type: New Construction Conditioned Floor Area: 2,326 ft2 Glazing Area 12% Climate Zone: 5 (6322 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Bldg G, Unit G2 North Andover, MA i MUM Compliance: 0.0%Better Than Code Maximum UA: 327 Your UA: 327 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Floor 1st Floor:All-Wood J oist/Truss:Over Unconditioned Space 416 30.0 0.0 0.033 14 Wall 1st Separation:Wood Frame, 16" o.c. 96 15.0 0.0 0.077 7 Wall 1st Ext 2x6:Wood Frame, 16"o.c. 812 21.0 0.0 0.057 40 Window Dh:Vinyl Frame:Double Pane with Low-E 32 0.290 9 Door Front Ground Fir entry: Glass 20 0.260 5 Door Back: Glass 34 0.290 10 Door Metal:Solid 18 0.160 3 Floor 2nd Over garage/entry:All-Wood joist/Truss:Over Unconditioned Space 481 30.0 0.0 0.033 16 Floor 2nd Over entry:All-Wood Joist/Truss:Over Outside Air 39 30.0 0.0 0.033 1 Wall 2nd Floor 2x6:Wood Frame, 16" o.c. 855 21.0 0.0 0.057 39 Window DH:Vinyl Frame:Double Pane with Low-E 100 0.290 29 Window Fix:Vinyl Frame:Double Pane with Low-E 19 0.280 5 Window CSMT:Vinyl Frame:Double Pane with Low-E 12 0.260 3 Door Slider:Glass 34 0.290 10 Wall 2nd Fir Separation:Wood Frame, 16" D.C. 279 15.0 0.0 0.077 21 Ceiling Bay Win: Fiat Ceiling or Scissor Truss 6 30.0 0.0 0.035 0 Wall 3rd Floor:Wood Frame, 16"o.c. 749 21.0 0.0 0.057 36 Window DH:Vinyl Frame:Double Pane with Low-E 86 0.290 25 Project Title: 150527 Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos_BIdgG_UnitsB6- Page 1 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2_Mode[B.rck Assembly Gross Area Cavity Cont. Perimeter Window Awn:Vinyl Frame:Double Pane with Low-E 7 0.270 2 DoorFrench:Glass 18 0.260 5 Wall 3rd Separation:Wood Frame, 16"o.c. 243 15.0 0.0 0.077 19 Ceiling Main: Flat Ceiling or Scissor Truss 936 38.0 0.0 0.030 28 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Notes: Building G Project Title: 150527—Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos BldgG_UnitsBB- Page 2 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2 ModelB.rck fZREScheck Software Version 4.6.1 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified " # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ?❑Does Not [PR111 energy code compliance for the ❑Not Observable V11 building envelope. ❑Not Applicable 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. s❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, }Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr ,❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 150527-Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust MerrimacCondos_BldgG_UnitsBB- Page 3 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModelB.rck 012 IECC Foundation Inspection Compiles? Comments/Assumptions 303.2.1 <;A protective covering is installed to ❑Complies [FO11]2 protect exposed exterior insulation ❑Does Not Q , ;and extends a minimum of 6 in, below grade. ❑Not Observable ❑Not Applicable 403.8 ;Snow-and ice-melting system controls'❑Complies [F012]2 installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 150527—Trust_Merrimac_BldciG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust MerrimacCondos_BIdgG_UnitsBB- Page 4 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModelB.rck Section Plans Verified . Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, 'Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 4023.6, ;❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products i❑Complies [FR4]1 are determined in accordance ❑Does Not J with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built '❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/LS.2/A440 or has infiltration rates per NFRC ;❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not } :and labeled to indicate <_2.0 cfm leakage at 75 Pa. I❑Not Observable ❑Not Applicable 403.2.1 Supply ducts in attics are R R- ❑Complies [FR12]1 insulated to>_R-8.All other ductsR_ R_ ❑Does Not in unconditioned spaces or outside the building envelope are,outside Observable 'insulated to>_R-6. ❑Not Applicable j 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,and filter boxes are =❑Does Not Ali sealed. ❑Not Observable ' ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. =❑Does Not '❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55°F are insulated to>_R- 3 ;❑Not Observable ❑Not Applicable 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.4.2 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3, ❑Does Not J ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 150527_Trust—Merrimac_BIdgG_UnitG2_ModelB Report date: 05/27/15 Data filename: 5:\Ebbeling_Ed\150507_Trust MerrimacCondos BldgG_UnitsBB- Page 5 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModelB.rck section Plans Verified Field Verified # Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air "❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 150527 Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507—Trust MerrimacCondos_BldgG_UnitsBB- Page 6 of 9 BB NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2_ModelB.rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 sAll installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not Q provided. _ ;❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per !❑Complies 402.2.7 manufacturer's instructions,and `❑Does Not [IN2]1 in substantial contact with the ❑Not Observable s underside of the subfloor. ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 150527 Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos_BldgG_UnitsBB- Page 7 of 9 BB_NAndover\Rescheck\150527 Trust_Merrimac_BldgG_UnitG2_ModelB.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope assemblies 402.2.1, ❑ Wood F-1 Wood ❑Does Not table for values. 402.2.2, 402.2.6 'E] Steel ';E] Steel ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies (F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. '❑Not Observable ❑Not Applicable 402.2.4 ,Attic access hatch and door R- R- ❑Complies [FI3]1 insulation >_R-value of the ❑Does Not V; adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= ❑Complies [FI17]1 'ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air >' '❑ , Not Observable handier @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 Air handier leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats 3❑Complies [Flg]z installed on forced air furnaces. '❑Does Not UY ❑Not Observable ❑Not Applicable 403.1.2 z Heat pump thermostat installed '❑Complies [F110]2 ion heat pumps. ❑Does Not y, ❑Not Observable . ❑Not Applicable 403.4.1 Circulating service hot water ❑Complies [F]11]2 systems have automatic or ;❑Does Not faccessible manual controls. ❑Not Observable ❑Not Applicable 403.5.1 All mechanical ventilation system ❑Complies [FI25]2 'fans not part of tested and listed ❑Does Not HVAC equipment rneet efficacy and airflow limits. ❑Not Observable ❑Not Applicable 404.1 75%of lamps in permanent ❑Complies [FI6]1 !fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. '❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 150527—Trust_Merrimac_BIdgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos_BldgG_UnitsBB- Page 8 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModeiB.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 404.1.1 Fuel gas lighting systems have ;❑Complies [FI23]3 no continuous pilot light. ❑Does Not f❑Not Observable 'E]Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ?❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F[18]3 mechanical and water heating =❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 150527 Trust_Merrimac_BIdgG_UnitG2_ModelB Report date: 05/27/15 Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos BldgG_UnitsBB- Page 9 of 9 BB_NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2_ModelB.rck r2012 IECC Energy 41 Effidency Certificate o . Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork(unconditioned spaces): Window 0.29 Door 0.29 Heating System: Cooling System• Water Heater• MOMMEMEM Name: Date• Comments Kanayo Lala, P.E. .............03/03/2014 PROJECT: Merrimack Condominiums G-TYPE BB-Compass Point,N Andover,MA DESIGN FOR-GIRDERS/JOISTS/RAFTERS Third Floor Beam T1 Supporting Floor,Wall,Attic&Point Load From T5 LOADS: DEAD LOAD 22.54 PSF 323.00 PLF Ce= 1 CF=1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 30.00 PSF 429.90 PLF qs= 29.10 Cd=1 TOTAL LOAD 753 PLF 1= 1 Cm= 1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD 3510 LBS 3.25 FT Ra= 2925 LBS 7341 LB=TOTAL REACTION TRIBUTARY WIDTH 14.33 LF E= 2000000 PSI JOIST/GIRDER SPAN 19.5 LF Fb= 2900 PSI WIDTH- IN 10.50 PSULVL 11.875 IN = d Fv= 285 PSI ROOF PITCH- N:12= Fc= 2700 PSI Fcp= 750 PSI MOMENT= 35786 LB-FT MOMENT2= 9506 LB-FT 246.78 =S provided OK S= 187.42 IN^3 1465.24 = I Deflection= 0.836 IN = U 240 For Total Load Required 1-/240 Deflection2= 0.139 IN = U 421 For Live Load Required L/360 Fcp'= 652 PSI OK 1.50 In Bearing Length Fv'= 123 PSI OK USE BETTER HEADER#65 (FLITCH BEAM) 2-LVLs 11 7/8"WITH 1/2"STEEL PLATE BOLTED WITH 5/8"DIA@12"O.C. IN TWO ROWS. t�of i� IUNavoH. ; LALA No.337100 °sfjFFgFCI STta�G�l IQ KL