HomeMy WebLinkAboutBuilding Permit # 6/9/2015 IJIL I PERMIT FORTH qq--
�F'KLFp, rb�•W�
TOWN OF NTH ANDOVER
APPLICATION FOR PLAN EXAMINATION
Permit No#: " Date Received d 'LiRp�mareo Pea q5
�SSACHUS��
Date Issued:
IMPORTANT: Applicant musty complete all items on this page
LOCATION 0,7)onax nl d/
Print
PROPERTY OWNER 0-(-1 0
Print 100 Year Structure yes
MAP l PARCEL: "�=ZONING DISTRICT:-" Historic District yes
Machine Shop Village yes r
I�
TYPE OF IMPROVEMENT PROPOSED USE
Residential Non- Residential
❑ New Building ❑ One family
[IAddition ITwo or more f mily ❑ Industrial
El Alteration No. of units: ❑ Commercial
❑ Repair, replacement ❑Assessory Bldg ❑ Others:
❑ Demolition ❑ Other
"::��r-,�, rr,,r . ,��/...,M�-x, , a::«.... ,,,r......,;iwt-, .. rradb +wr,fw ,lr il. riri✓, )f �12�rN p"�`�(� 1(NlJ;�1J.; .1�I✓r/1J11f.1/rl1Nf, /„ i�/r/%s
tIC `s "JAI 'ayF Qpd JIt�r Wlatd ', Wt�C00 SCI' ,IStrlCtol'i; /`
r . ,�"
DESCRIPTION OF WORK TO BE PERFORMED:
n o Cam
Ide i icati - Pleas Type or Print Clearly
OWNER: Name: " t r Phone: 3,St , q
Address: 1'`v" 'v t l
10
Contractor ame: `w . Phone: �,'> 90 3"
Email: "
Address: ,(L, .v , C 151C
Supervisor's Construction License:- CS 05q Exp. Date: 1 a 1
Home Improvement License: \� �] Exp. Date: 1 �
ARCHITECT/ENGINEERnU',1l Phone: 00 3-1
Address: 1 - gig tilauo Reg. No. ' j lD–t—
FEE SCHEDULE.BULDINC7 PERMIT:$92.00 PER$9000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F.
Total Project Cost: $ FEE: $
Check No.: Receipt No.:
NOTE: Persons contracting with unr istered contractors do not have access to the uaranty fund
�/Jy/�c,[!n r,J%'af��d!1/,%,�i7r/l� a.:r,r^' „^,r:r;,:.J r i17i-i-.,,,.. %///i 77""/ r!i,.r, roT/,"//"o—fi'i//./'✓,//Pf%,: re,/,i 4',¢. .i, „ „,1%// �r�/ .,��r�f�///�i/f///%
i
Plans Submitted ❑ Plans Waived ❑ Certified Plot Flan ❑ Stamped Plans ❑
TYPE OF SEWERAGE DISPOSAL
Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools ❑
well ❑ Tobacco Sales ❑ Food Packaging/Sales ❑
Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑
.................
THE FOLLOWING SECTIONS FOR OFFICE USE ONLY
INTERDEPARTMENTAL SIGN OFF ® U FORM
PLANNING & DEVELOPMENT Reviewed On Signature_
COMMENTS
CONSERVATION Reviewed on L Si nature""'
COMMENTS LI — �
HEALTH Reviewed on Signature
COMMENTS
Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes
Planning Board Decision: Comments
Conservation Decision: Comment
Fater& Sewer Connection/sil nature ID Driveway Permit
]DPW Town:Engineer: Signature: a "� ,-
Located 384 Osgood Street IARdTI�IE '
FIRE DEP' r NST,„ Ternp Dum er on %`
i�d4.,.%i(rl n„ n, �/�:1 rlrP„� � /!%Pll//KI/NA-1111111
Locd'
at d of 12
e n 4 MainStreet
F./.e ® , < , :;
jir✓i /,!i /i ';/r / fi
CQMMENi
t%oRTH
-Town ofE 1. ndover
® 0
®
h ver, Mass, 4CAX
OLAKE
A- COC KICKEWICK
9® RATED
S u
BOARD OF HEALTH
Food/Kitchen
PERMIT LD Septic System
THIS CERTIFIES THAT . . ..,. ........ 1.04C .. ... .. BUILDING INSPECTOR
has permission to erect .......... buildings on ...4Q;.(. .c gS Foundation
��� Rough
tobe occupied as ....... r......� ...... �..\.. .. 1.1 ................................................. chimney
provided that the person acce this er it shall in eve respect conform to the terms of the application Final
on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and
Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR
VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough
Final
PERMITI IN 6 MONTHS ELECTRICAL INSPECTOR
i� LESS CTI® R Rough
Service
.................... ... ....... ............................................ Final
BUILDING INSPECTOR
GAS INSPECTOR
Occupancy Permit Required t® Occupy Building Rough
Islay in a Conspicuous Place on the Premises — Do Not Remove Final
No Lathing or Dry Wall To Be Done FIRE DEPARTMENT
Until Inspected and Approved by the Building Inspector. Burner
Street No.
Smoke Det.
t ;
r
,.
014
LD
IJ
w , «
G
BLDG"0" �
i
c �
ow?�.
7 CERTIFIED PLOT PLAN
iNO OrHm um "roan
MMUWY LOCI WD
TS S*MW AK MWD ON T
W== PLAM FM 'R" MKM TW rWMAnIN AS SHMM IMS NUT'
VIAW MMW O"TE IMWDM & TO PMWRTY LTW
1 �OFT7" 4 f
: m
TKS M IS TO BE USCD TU -tCST , U Y Taw
&TRUCTUXS, OR FCR LANDXWM MYKA
-gg�
T"ELY FtOdSWD BY AS9194,MAP&LOT ft
THE M(WR TU TW F'Dft
s
E ROUTE 114, ¢NORTH ANDOVER, MASS,
PROJECT t ND1 ALE, V=40'
`
DRAWN BYt PCG DATEt 5/1/15
CHECKED BYtSC SHTt I
VISM
OFt I
Scheck Software Version 4.6.1
C�(J Compliance Certificate
Project 150527 Trust Merrimac_BIdgG_UnitG2_ModelB
Energy Code: 2012 IECC
Location: North Andover, Massachusetts
Construction Type: Multi-family
Project Type: New Construction
Conditioned Floor Area: 2,326 ft2
Glazing Area 12%
Climate Zone: 5 (6322 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Bldg G, Unit G2
North Andover, MA
i MUM
Compliance: 0.0%Better Than Code Maximum UA: 327 Your UA: 327
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Perimeter
Floor 1st Floor:All-Wood J oist/Truss:Over Unconditioned Space 416 30.0 0.0 0.033 14
Wall 1st Separation:Wood Frame, 16" o.c. 96 15.0 0.0 0.077 7
Wall 1st Ext 2x6:Wood Frame, 16"o.c. 812 21.0 0.0 0.057 40
Window Dh:Vinyl Frame:Double Pane with Low-E 32 0.290 9
Door Front Ground Fir entry: Glass 20 0.260 5
Door Back: Glass 34 0.290 10
Door Metal:Solid 18 0.160 3
Floor 2nd Over garage/entry:All-Wood joist/Truss:Over Unconditioned Space 481 30.0 0.0 0.033 16
Floor 2nd Over entry:All-Wood Joist/Truss:Over Outside Air 39 30.0 0.0 0.033 1
Wall 2nd Floor 2x6:Wood Frame, 16" o.c. 855 21.0 0.0 0.057 39
Window DH:Vinyl Frame:Double Pane with Low-E 100 0.290 29
Window Fix:Vinyl Frame:Double Pane with Low-E 19 0.280 5
Window CSMT:Vinyl Frame:Double Pane with Low-E 12 0.260 3
Door Slider:Glass 34 0.290 10
Wall 2nd Fir Separation:Wood Frame, 16" D.C. 279 15.0 0.0 0.077 21
Ceiling Bay Win: Fiat Ceiling or Scissor Truss 6 30.0 0.0 0.035 0
Wall 3rd Floor:Wood Frame, 16"o.c. 749 21.0 0.0 0.057 36
Window DH:Vinyl Frame:Double Pane with Low-E 86 0.290 25
Project Title: 150527 Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos_BIdgG_UnitsB6- Page 1 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2_Mode[B.rck
Assembly Gross Area Cavity Cont.
Perimeter
Window Awn:Vinyl Frame:Double Pane with Low-E 7 0.270 2
DoorFrench:Glass 18 0.260 5
Wall 3rd Separation:Wood Frame, 16"o.c. 243 15.0 0.0 0.077 19
Ceiling Main: Flat Ceiling or Scissor Truss 936 38.0 0.0 0.030 28
Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.6.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Notes:
Building G
Project Title: 150527—Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos BldgG_UnitsBB- Page 2 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2 ModelB.rck
fZREScheck Software Version 4.6.1
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the"Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
section Plans Verified Field Verified "
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ?❑Does Not
[PR111 energy code compliance for the ❑Not Observable
V11 building envelope.
❑Not Applicable
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. s❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, }Heating and cooling equipment is Heating: Heating: ❑Complies
403.6 sized per ACCA Manual S based Btu/hr Btu/hr ,❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: 150527-Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust MerrimacCondos_BldgG_UnitsBB- Page 3 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModelB.rck
012 IECC Foundation Inspection Compiles? Comments/Assumptions
303.2.1 <;A protective covering is installed to ❑Complies
[FO11]2 protect exposed exterior insulation ❑Does Not
Q ,
;and extends a minimum of 6 in, below
grade. ❑Not Observable
❑Not Applicable
403.8 ;Snow-and ice-melting system controls'❑Complies
[F012]2 installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 150527—Trust_Merrimac_BldciG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust MerrimacCondos_BIdgG_UnitsBB- Page 4 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModelB.rck
Section Plans Verified . Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, 'Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
4023.6, ;❑Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products i❑Complies
[FR4]1 are determined in accordance ❑Does Not
J with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built '❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/LS.2/A440
or has infiltration rates per NFRC ;❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.4 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
}
:and labeled to indicate <_2.0 cfm
leakage at 75 Pa. I❑Not Observable
❑Not Applicable
403.2.1 Supply ducts in attics are R R- ❑Complies
[FR12]1 insulated to>_R-8.All other ductsR_ R_ ❑Does Not
in unconditioned spaces or
outside the building envelope are,outside Observable
'insulated to>_R-6. ❑Not Applicable j
403.2.2 All joints and seams of air ducts, ❑Complies
[FR13]1 air handlers,and filter boxes are =❑Does Not
Ali sealed.
❑Not Observable '
❑Not Applicable
403.2.3 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. =❑Does Not
'❑Not Observable
❑Not Applicable
403.3 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105°F or chilled fluids ❑Does Not
below 55°F are insulated to>_R-
3 ;❑Not Observable
❑Not Applicable
403.3.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.4.2 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3, ❑Does Not
J ❑Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: 150527_Trust—Merrimac_BIdgG_UnitG2_ModelB Report date: 05/27/15
Data filename: 5:\Ebbeling_Ed\150507_Trust MerrimacCondos BldgG_UnitsBB- Page 5 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModelB.rck
section Plans Verified Field Verified
# Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions
& Req.ID
403.5 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air "❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: 150527 Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507—Trust MerrimacCondos_BldgG_UnitsBB- Page 6 of 9
BB NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2_ModelB.rck
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 sAll installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
Q provided.
_ ;❑Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel ❑Not Observable
❑Not Applicable
303.2, Floor insulation installed per !❑Complies
402.2.7 manufacturer's instructions,and `❑Does Not
[IN2]1 in substantial contact with the ❑Not Observable
s underside of the subfloor.
❑Not Applicable
402.1.1, Wall insulation R-value.If this is a R R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: 150527 Trust_Merrimac_BldgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos_BldgG_UnitsBB- Page 7 of 9
BB_NAndover\Rescheck\150527 Trust_Merrimac_BldgG_UnitG2_ModelB.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope assemblies
402.2.1, ❑ Wood F-1 Wood ❑Does Not table for values.
402.2.2,
402.2.6 'E] Steel ';E] Steel ❑Not Observable
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
(F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. '❑Not Observable
❑Not Applicable
402.2.4 ,Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation >_R-value of the ❑Does Not
V; adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= ❑Complies
[FI17]1 'ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
>' '❑
, Not Observable
handier @ 25 Pa. For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.2.2.1 Air handier leakage designated ❑Complies
[FI24]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats 3❑Complies
[Flg]z installed on forced air furnaces. '❑Does Not
UY
❑Not Observable
❑Not Applicable
403.1.2 z Heat pump thermostat installed '❑Complies
[F110]2 ion heat pumps. ❑Does Not
y,
❑Not Observable .
❑Not Applicable
403.4.1 Circulating service hot water ❑Complies
[F]11]2 systems have automatic or ;❑Does Not
faccessible manual controls.
❑Not Observable
❑Not Applicable
403.5.1 All mechanical ventilation system ❑Complies
[FI25]2 'fans not part of tested and listed ❑Does Not
HVAC equipment rneet efficacy
and airflow limits. ❑Not Observable
❑Not Applicable
404.1 75%of lamps in permanent ❑Complies
[FI6]1 !fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. '❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: 150527—Trust_Merrimac_BIdgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos_BldgG_UnitsBB- Page 8 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BldgG_UnitG2_ModeiB.rck
Section
Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
404.1.1 Fuel gas lighting systems have ;❑Complies
[FI23]3 no continuous pilot light. ❑Does Not
f❑Not Observable
'E]Not Applicable
401.3 Compliance certificate posted. ❑Complies
[FI7]2 ?❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F[18]3 mechanical and water heating =❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 150527 Trust_Merrimac_BIdgG_UnitG2_ModelB Report date: 05/27/15
Data filename: S:\Ebbeling_Ed\150507 Trust_MerrimacCondos BldgG_UnitsBB- Page 9 of 9
BB_NAndover\Rescheck\150527 Trust Merrimac_BIdgG_UnitG2_ModelB.rck
r2012 IECC Energy
41 Effidency Certificate
o .
Above-Grade Wall 21.00
Below-Grade Wall 0.00
Floor 30.00
Ceiling / Roof 38.00
Ductwork(unconditioned spaces):
Window 0.29
Door 0.29
Heating System:
Cooling System•
Water Heater•
MOMMEMEM
Name: Date•
Comments
Kanayo Lala, P.E. .............03/03/2014
PROJECT: Merrimack Condominiums
G-TYPE BB-Compass Point,N Andover,MA
DESIGN FOR-GIRDERS/JOISTS/RAFTERS Third Floor Beam T1
Supporting Floor,Wall,Attic&Point Load From T5
LOADS: DEAD LOAD 22.54 PSF 323.00 PLF Ce= 1 CF=1.00
SNOW LOAD PSF 0.00 PLF Cq= 1 Cs=
LIVE LOAD 30.00 PSF 429.90 PLF qs= 29.10 Cd=1
TOTAL LOAD 753 PLF 1= 1 Cm= 1
WIND SPEED 100 MPH 29.10 PSF
POINT LOAD 3510 LBS 3.25 FT
Ra= 2925 LBS 7341 LB=TOTAL REACTION
TRIBUTARY WIDTH 14.33 LF E= 2000000 PSI
JOIST/GIRDER SPAN 19.5 LF Fb= 2900 PSI
WIDTH- IN 10.50 PSULVL 11.875 IN = d Fv= 285 PSI
ROOF PITCH- N:12= Fc= 2700 PSI
Fcp= 750 PSI
MOMENT= 35786 LB-FT
MOMENT2= 9506 LB-FT 246.78 =S provided OK
S= 187.42 IN^3 1465.24 = I
Deflection= 0.836 IN = U 240 For Total Load Required 1-/240
Deflection2= 0.139 IN = U 421 For Live Load Required L/360
Fcp'= 652 PSI OK 1.50 In Bearing Length
Fv'= 123 PSI OK
USE BETTER HEADER#65 (FLITCH BEAM) 2-LVLs 11 7/8"WITH 1/2"STEEL PLATE
BOLTED WITH 5/8"DIA@12"O.C. IN TWO ROWS. t�of