Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit # 6/11/2015
ppRTH p �t�n° �b• �p j BUILDING PERMIT TOWN OF NORTH ANDOVER ° APPLICATION FOR PLAN EXAMINATION y Permit NO: Date Received q° A. �9SSgCHt1S Date Issued: IMPORTANT: Applicant must complete all items on this page rrr. a ✓ /, / i / / rr �r r r rill'2/r�rr,�r�rrP0 IFS// WOMEN ///r, � / / i on, r r ,, � //�ii// // I, //li//,/rrr/,/ I e /r �, ✓�// ra r , /,✓i/ilii r /, 1. /, , ,i/ / TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential New Buildingne family LkAddition `� �r��. ❑ Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other r ❑/,ii///�,r_i/,, ',ft/i/Cr/,„ii%r�--/,.':i„ �.I/i1�"//'rrr,�,,r, ,,,, ,,; ,//iri, ❑ 6 c n i ,/ U,,,/,// /VIN% //r „ , r Identification Please Type or Print Clearly) OWNER: Name: C VS J_,: C'.0VI 1-t-0 Phone: (J-7 411-14 `��>,����: � Adess: x-rr ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ m FEE: $ 70 Check No.: 0 / Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to the guar my fund( / Signature of Agent/Owner Signature,of contractor Gt l� JAMES L . CLANCY PROFESSIONAL ENGINEER 601 ASBURY AVENUE NATIONAL PARK, NJ 08063 (856) 358-1125 FAX: (856) 358-151 Date: May 12,2015 Re: Structural Roof Certification Subj: David Iacoviello Residence, 150 Liberty Street,North Andover MA 01845 We have provided a review of the house roof construction of the above named property in regards to verifying the capacity of the existing roof for installation of a new Solar Panel Array. We have found the residence roof to be of wood frame construction bearing walls with Roof 1 of 2x10 @ 16"rafter framed roof with 1x8 collar ties @ 32" o.c. and is sheathed with 1/2" ext-ply decking and a single layer of composite shingle roofing. The wood framed roof structure bears directly upon the framed exterior wall system. The existing members as installed meet the required (MA 780 CMR) IRC-2009 table 802 design span ratings with sufficient capacity to carry the 2.89#/sf additional load imposed by the proposed solar array per the details below. Installation of solar rack systems shall be as follows: Each panel row shall be supported upon 2 mounting rails. Rails shall be screw anchored through roof and directly to rafters or purlins below. Rail attachment points to rafters shall be staggered each row with exception to the first fastener row from the gable end which is attached to two adjacent rafters/trusses with Stainless Steel fasteners. Rail attachment to roof shall be fastened 16-32"o.c. at corners and 48"o.c. through the field. Rails are to be placed at 24-48"o.c. on the roof. When installed per the above specifications the system shall meet the required 105 MPH wind load and 50 PSF ground snow load requirements. Should you have any further question or comment please feel free to contact our office. Respectfully, , OF AMEN�. CLAN Y 0. TYIa James A. Clancy Professional Engineer MA License#46775 'Proprietary and Confidential Inrom,cucn. REVISIONS: Di.[—.without prior consent of at.Seienium Solar,LIG b Ell, . ROOF NO. DATE BY ECN 26' I I I I i I 0 i 1 18' 3 1 � I RESIDENTIAL SOLAR PHOTOVOLTAIC INSTALLATION: 18' IACOVIELLO, DAVID 150 LIBERTY STREET, NORTH ANDOVER, MA 01845 TL :1E] 1 MODULES: SUNPOWER SPR-E20-327 TOTAL SYSTEM SIZE: f 42' . 39 MODULE x 327W= 12.75 KW-DC ROOF 1 TOTAL EST PROD= 13,829 KWH/YR �� 8 A. WEST FACING ROOF 1: OY AVERAGE TSRF=75.77%D ROOF TILT=33.69 DEG AZIMUTH =261 DEG INVERTER: 33 MODULE x 327W= 10.791 KW James A. Clancy, PE - 2 x SMA SB6000TL-US-22 EST PROD= 11,880 KWH/YR 601 Asbury Avenue w/TIDO DC OPTIMIZERS (PV SIM 6%D SHADE) National Park, NJ 08063 Massachusetts PE Lie#46775 NORTH ANDOVER, MA EAST FACING ROOF 2: RECORD LOW=-27 DEG C ROOF TILT=33.69 DEG BLUE SELENIUM SOLAR, LLC AVERAGE HIGH =29 DEG C AZIMUTH =81 DEG 17 JAN SEBASTIAN DRIVE,SUITE 12,SANDWICH,MA 02563 RECORD HIGH=39 DEG C 6 MODULE x 327W= 1.9621 KW PHONE(508)833-9500.WWW.BLUESEL.COM WIND SPEED= 105 MPH EST PROD= 1,949 KWH/YR SNOW LOAD=50 PSF (PV SIM 8%D SHADE) DRAWN BY:OC DATE:04-0815 SCALE:WA SHEET:t OF BORDER:C NAME I DWG NUMBER-REV NORTH ANDOVER- 150 LIBERTY ST. 02383-01 *P,.P,I.t.,y and r"ffkk".[Ifrw.6 . I REVISIONS: DI'looure wMwd prior consent of 81 I NO. DATE BY ECN ft -S.I..Iu.Sol.,.LLC I.p,.hibftd- 26' 16"O.C. RAFTER SPACING +jy LJ I II i r RESIDENTIAL SOLAR 9 i i PHOTOVOLTAIC INSTALLATION: I 61 4 I rpi!-1 1 18' =4 IACOVIELLO, DAVID i -M 1 -111 1 1 M I rl I I I i M I 150 LIBERTY STREET, NORTH ANDOVER, MA 01845 M MODULES: SUNPOWER SPR-E20-327 42' TOTAL SYSTEM SIZE: I ROOF 1 F 39 MODULE x 327W= 12.753 KW TOTAL EST PROD= 13,829 KWHNR WEST FACING ROOF 1: CY AVERAGE TSRF=75.77% ROOF TILT=33.69 DEG AZIMUTH =261 DEG INVERTER: 33 MODULE x 327W= 10.791 KW James A. Clancy, PE 2 x SMA SB6000TL-US-22 EST PROD= 11,880 KWH/YR 601 Asbury Avenue W/TIDO DC OPTIMIZERS (PV SIM 6%SHADE) National Park, NJ 08063 Massachusetts PE Lic#46775 NORTH ANDOVER, MA EAST FACING ROOF 2: RECORD LOW=-27 DEG C ROOF TILT=33.69 DEG BLUE SELENIUM SOLAR, LLC AVERAGE HIGH =29 DEG C AZIMUTH =81 DEG 17 JAN SEBASTIAN DRIVE,SUITE 12,SANDWICH,MA 02563 RECORD HIGH=39 DEG C 6 MODULE x 327W= 1.9621 KW PHONE�508)833-9500.WWW.BLUESEL.COM WIND SPEED= 105 MPH EST PROD= 1,949 KWHIYR SNOW LOAD=50 PSF (PV SIM 8% SHADE) DRAWN BY:OC DATE,04-0&15 SCALE:ITA SHEET.*20F3 _L= II .EC I NAME: DWG NUMBER-REV NORTH ANDOVER- 150 LIBERTY ST. 102383-01 'Proprietary and ConffdeMtal info"nallon. REVISIONS: D1.1o.ro without pdor consent of Blue SebN..Solar,LLC b prohibited' NO. DATE BY ECN# 2 X 12 RIDGE BEAM 1 X 8 COLLAR TIES SOLAR PANEL 32"OC 2 X 10 RAFETRS 16"O.C. 18' 34a RESIDENTIAL SOLAR PHOTOVOLTAIC INSTALLATION: 13'-5-2L"SPAN (ACOVIELLO, DAVID 150 LIBERTY STREET, I NORTH ANDOVER, MA 01845 PANEL AND MOUNTING INFORMATION: ROOF TILT: 8/12 PITCH (33.69 DEG) AZIMUTH 1 -261 DEG AZIMUTH 2-81 DEG RAFTERS: 2 x 10, 16"OC, SPAN = 13'-5.5" MODULES: SUNPOWER SPR-E20-327 ' 1= 39 MODULES x 327W= 12.75 KW-DC S A. RACK/RAILS: SUNPOWER SOLARMOUNT O (UNIRAC SOLARMOUNT)OR EQUIVALENT FLASHING: PV QUICK MOUNT W/5/16"x 3-1/2"SS LAG James A. Clancy, PE OR EQUIVALENT 601 Asbury Avenue National Park, NJ 08063 NOTES: Massachusetts PE Lie#46775 4 FT. MAX SPACING BETWEEN "L-BRACKETS" ALL BRACKETS ARE SECURED TO ROOF RAFTERS BLUE SELENIUM SOLAR, LLC 17 JAN SEBASTIAN DRIVE,SUITE 12,SANDWICH,MA 02583 NORTH ANDOVER, MA fa PHONE(508)833-9500,WWW.BLUESEL.COM WIND SPEED= 105 MPH DRAWN BY:OC I DATE:04.08.15 SCALE:WA SH-3 OF3 BORDER:C SNOW LOAD=50 PSF NAME: DWG NUMBER-REV NORTH ANDOVER- 150 LIBERTY ST. 02383-01 D'PropeWtory md Codlid" =- al REVISIONS, W—.wfthout pri"� Sk.S.I.M..Solar,LLC 1.pmhb#.d" NO. DATE JBY J ECN It 8 PCS 3E7 WATT MODULES Wl/ 4 PCS TIG3 DC OPTIMIZERS SZMA INVERTER 1 56000_- L- 40 YLL 6 PCS 327 VATI T MODULES DC DISCONNECT SunTCH W/ 3 FCS TIDO DC OPTIMIZERS GND ----------El Ll L2 N GND ROOF MTD IPEPEPFZI 'UNCTION BOX ---EEEP- ----------- R 0 U IND 6 PCS 327 WATT MODULES NEUTRAL V W/ 3 PCS TIC-0 DC OPTIMIZERS TO T_-00 MANAGEMENT UNIT #12 AWG THWN #6- AWG 310 4AWG THWN-2 w. i 11 THWN-2 > TIGG ENERGY VIRELESS GATEWAY (MTD ON ROOF) + B A + R A 45-485 CABLE, 4 CONDUCTOR, TWISTED PAIR, OUT DOOR RATED, 18 AVG M714. TYP PLIC/ITC, 30OV, 0.31' DIA OR LESS MAY BE USED. REST DENTTAL SOLAR PHO V 2�' T TO L I A!C, SNS A! AT!ON NOANDOVER,ANDOVER, MA BLUE SELENIUM SOLAR, LLC TACOVIDL 1 , DID REC OR LOW = -27 DU 17 JAN SEBASTIAN DRIVE, SUITE 12, SANDWICH, MA 02563 L_ i — 0AVi Dil I* PHONE (508)M-9500, WWV.BLUESEL.COM 50 LI B DR, v S R E RECORD HIGH1 = 39 DEG -E HI(--H = 20 DEG DATE- 04/06/15 1 SCALE, N/A SHEET- I 13F 4 1 BORDER, C DRAWN BY, 13C NIORTH ANDOVER,, MA 01-854 AV7RAG k_J IjNAME- DWG NUMBER-REV PV WIRING - IACOVIELLO 102443-00 'P,We.,jd 0=66.ftl Inft—ion I REVISIONS, DiseWum wM-'priorowsom of I1 JJ 8k.S.I..Iu.Solar,LLC 1.prohtftd* N0. DATE BYECN #1 7 PCS 327 WATT MODULES w;4 Ki T11100 DC OPTIMIZERS SMA NVER-1 ER 2 5B6000-TL-240 6 PCS 327 WATT MODULES DC DISCMN-NECTSWITCH E W 3 PCS T 1GO D-1 OPTIMIZERS GND -------El I L2 N END RADE MTD EFEKI [PIPIPEP JUNCTION BOX (+> GROUND 6 PCS 327 WATT MODULES W/ 3 PCS Tl_c_Gl DC OFTIMITZERS f, NEUTRAL is L2 Ll L #12 AWG THWN-2 #8 AW -'110 AWG THWGN-2 !7Q t THWN-2 (-> RLESILDT EN I !AL SOLAR T PHEIFIFOVEIL , AIS INSTALLATION NOR H ANDOVER, MA BLUE SELENIUM SOLAR, LLC TI iNCOVIEILLD. DAVID RECORD LOW -_27 DEG 17 JAN SEBASTIAN DRIVE, SUITE 12, SANDWICH, MA 02563 1550 LTBERTY STRELET RECEIRD HIGIH ---Q/ DEG 10 PHONE (509)833-9500, WWW.BLUESEL.CDM L L_ - HMH 9 D FE G DRAWN BY, 13C DATE- 04/06/15 1 SCALE, N/A SHEET, 2 13F 4 1 BORDER, C NORTH ANDOVER, MA Oi8':-)4 AV'RAGE NAME- DWG NUMBER-REV PV WIRING - IACOVIELLO 102443-00 --. I I REVISIONS, Mm Selenium Solar.U.0 1.pmhWAd- NO. DATE BY ECN # UTILITY SERVICE NET METER 0 AC KVH COMBINER LOCUS FUSED PANEL PRODUCTION EXTERNAL AC 44 THWN-2 (INT;METER DESCONNECT 44 _1.mWN-P_ 3C + GND 00 AMP, 3C + GND USES 70 AMP> CBI-Ll 350 A IP LINE I ---OJ:O— 2 CB!-L2---o NEUTRAL G ND -A 1P v v CK-LPo o— SERVICE i PANEL BRE A€ER NEUTRAL! BUS BAR! BO NEUTRAL21 BUS BAR 3 AC LIGHTNING ^OUA 0 ARRESTOR 0 GROUND BUS RAR2 GROUND BUS BAR! 0- q:zlii 0 0- S7 RE iSENT IA1 SOLAR T T P H 0 T'0!V 01— A T C TNSTALLA ON L I _1 NOR H ANDOVER, MA BLUE SELENIUM SOLAR, LLC 17 JAN SEBASTIAN DRIVE, SUITE 12, SANDWICH, MA 02563 CORD 'LOW —27 DEIG TACOV ELLO, DAVIID R_ PHONE (508)833-9500, WWW.BLUESEL.CBM .1 cz TD 1 E E-R-1, Y S REET RECORD H'GH - - 9 DF1 jo 1 — A DRAWN BY- OC DATE, 04/06/15 1 SCALE- N/A SHEET- 3 13F N LF_-.11Ri ANDOVE-R, MA 01854 m V LE R A G I-E HTGH = 2 0 E 1-3 NAME- DWG NUMBER-REV PV WIRING — IACOVIELLO 102443-00 'Pmpd.t.q-d Cama Wwmam I I REVISIONS, Dls.k�Wh�A pftr coramA of I Blas Sjanl..Solar.LLC is pmhh*bd" NO. DATE BY ECN 0 2-2.2 2-2.2 2-22 2-22 2-2.2 2-2.2 RESTDIENT' I'Al SOLAR — T 1 T IlDHOTOVOLT AIr_ �N S Tin M1—LA T EIN 1 2-2.1 2-2.1 2-2.1 2-2.1 2-2.1 2-2.1 2-2 2-2 2-2 2-2 2-2 7 iACDVTELLO, DAVID I P[:Z 1 T _RTi Y .L,jw l_.LBLE —S R E E T NORTH ANDOVER,, MA 01854 1-2.1 1-2.1 1-2.1 1-2.2 1-2.2 1-2.2 1-2.2 1-2.2 1-2.2 2-2 2-2 T INVERT ER 1 M P 11)T 1 T T rDPT 2�S_l RiNG 1-2� INVERTER 1 Ma I 1 1-2.1 1-2.1 1-21 1-1 1-1 INVER—! ER 2 MPPT '),Sr- -' RTN L R T LE R 2 MPP 1 1 T 1 INVERT ER 2 Mic'I' l P,S T R RANG, 2-222 1 AVER T E R 2 MPPT 2,S T R I NG3 T 1 �- I INVER T ER = 2 X SMA SB�601U 0TL-240 i NORTH ANDOVER, MA RECORD` 'LOW 2 7 DEG BLUE SELENIUM SOLAR, LLC T < RLE-CORD HiGH —9 SLC 17 JAN SEBASTIAN DRIVE, SUITE 12, SANDWICH, MA 02563 A E RAGS G LE 1—ITIG H _/ , i VE i�Ul = 29 DEC- PHONE (508)933-9500, WWV.BLUESEL.COH IND SPEED 10 55, M P H DRAWN BY- 13C DATE- 04/06/15 1 SCALE- N/A SHEET- 4 OF ! BORDER- C WG NUMBER-REV -0 PS F NAME- SNOW LOAD 5 PV WIRING — IACOVIELLO 102443-001 Ow ELECTN'ICIANA ° t W0332806 ISSUES THE FOLLOWING LICENSE AS A.REO JOURNEYMAN LECT I C I AN 0Ba DANIEL J MCGRATH TH I ux�araN mr 114 SOyLSTON ST ;ALDEN MA 02146-7931 DepartMaInt Of PU*44C S004 la VI tai f 3 o �B yap e r / / L4 neue. CSFA 104676 , IDA ULJ MCGR,ATH, 114 BOYLST+l 14 MAI.LIE[Y MA 0114817 ��ji�al f�tial �j�%lid ti ai 1)1ui iiV ���� l %2... 09/1512016 / ✓iii/i/ri�/ i iG / /r/i / l ELEC'T1tIC:AL L9NLIM1'1""EE►JOURNEYPERSONo a�umer Affairs Business..�_ . DANIEL J MCGRATH ffice of C Regulation 114 BOYLSTON ST ME IMPROVEMENT CONTRACTOR MI ALDEN,MA 02148-7931 a egietration: 168524 Type: expiration: 3/7/2017 Individual DANIEL MCGRATH LC.019 'i3-E2 10101/2014 09/30/2015 �� DANIEL MCGRATH 9 114 BOYLSTON ST MALDEN,MA 02148 Undersecretary STATE OF MAINE DEPT ELECR'r�RIC LMINING BOARD REGULATION r LICENSE#1111111160020703 DANIEL MCGRATH MASTER ELECTRICIAN ISSUED Aug 26,2013 EXPIRES,Aug 31,2015 BLUESEL HOME SOLAR Residential Solar Energy System Installation Agreement (Retail Installment Sale Agreement-Subject to State Regulation) r David & Phyllis lacoviello yite: 150 Liberty St. , N. Andover, MA 01845 f! C, No (617) 448-8222 !,1),311 d&ve.iacoviQ1108gmakil-c0m.— Rate Cope Residential Regular R-1 NationalGrid C--Co it 78556-64004-- - 12.753 S'p"Tem, 39 riv pv P,,,�Id�jrtjow 14,215 kWo 11 �,v�jr�ij�o/Them),il i3m)e)NldflulActt0e� & Sunpower 327W C,-,, 1 7 ------------ laj 2 Sb% -,7 1 ;'j w qoipmriDC Optimizers, Locus or DAT 10yr Reporting �t Azwer,;joifli:� 'ttdattached, W�flno The Preliminary System&Total Price shown are based upon estimates.When you sign this Agreement you have a R!Iht to Cancel.When that Final System Design Process(Section 2).40 AW,' (initials) right�expires�(Secfion 1q),Installer will provide a Final System Design See Fl 65,335 Financed:iota, 7� f PRS $10,500 Pa ient chellule pp 50 T,-t,31 Loot,M,,;!,nt$18,851 1,f rl 23400535 $9,04X ,a! toi,: 111$9,425.50 -,-,$9,425.50 0 0 5pi�:,ai oi -r equipment(50 $ $3 El rd,<Credit .5 0 o start �-Ljte upo;)involcf-(15:,", $15 08 prior I *SAC Loan must be paid within 36S 0 days 0 months' i r,tt. upc)ll Proiect (R11)$35,984 U,-! P2340053702 $6 032 10 ytj�jr,� 111L mrj),ply P,�, $--34-7 RILRate 2.99 % 0 salt-, t.o P1 e utility provider will not permit Interconnection,and the corrective If,due to existing conditions a municipal authority will not issue a permit or th If, notification of same by Installer,Customer shall have ten (10) calendar days in which to measures needed will cost more than $1,600, upon not 11 return all funds paid by Customer,save for Agreement shall b-.-.-. M: /,#.r (initials)., n(7)days of such cancellation,Installer sh cancel this Agreement by notifying Installer. Within seven cancel frees paid to the municipality and for engineering studies,upon which this Massachusetts Home Improvement Contractor Registration Number:166151,expires April 29,2016 by a party thereto at a place e other than an address of the seller,which may may cancel this agreement if It has been signed , at his main office or branch, by ordinary Mail be his main office or branch thereof, provided you notify the seller in writing posted,by telegram sent or by delivery,not later than midnight of the third business day following the signing of this agreement. See the attached Notice of Cancellation form for an explanation of this right. Cancellation (initials&date) I was informed of my Right to Cancel and provided with two Notices of I -ML NOTICE TO BUYER: 1/1 811f 1.Do not sign this Agreement if any of the spaces Intended for the agreed terms to the extent of then available information are left blank. 2.You are entitled to a copy of this Agreement at the time you sign it. and In so doing you may receive a partial rebate 3.You may at any time pay off the full unpaid balance due under this agreement,a of the finance e and Insurance charges. by a writing signed by pa S. This agreement, i d as a sealed instrument,can only be changed a r�e, De Date: me(; Date: 'S" BlueSe Jar, Dealer IDIt BlueSel Home soisr,Inc. 600 W.Cummhga Perk 17 Jan Sebamian Dive The terms of this agreement are contained on more than one page. (781)281-8130 Page I of 5 Fax:(508)833-9501 Suite 4200 SidleQ www.8kieSel.com Wobum,MA 01801 SandMch,MA 02583 This Agreement is by and between Customer and BlueSel Home r) "Sales Representative" — The person with whom Customer Solar,Inc.,for the purchase and installation of the System primarily dealt prior to the signing of this Agreement and who described herein. The terms,rights,obligations,and warranties of acted on behalf of installer. each party are governed by this Agreement. s) "Site" — The address, identified in the Customer section on the first page of this Agreement, at which Installer shall install 1) Definitions the System. a) "Agreement Date" — The latter of (i) the date on which t) "Solar Site Assessment" — A review of the Site that may Customer and Installer sign this Agreement; and (ii)the date include, but is not limited to, measurements of the location on which Customer is provided a fully signed copy of the where the System will be installed, a review of the existing Agreement. surface and structure intended to support the System, a b) "Balance of System" — The items, equipment, and materials shading analysis, and a review of the Site's existing electrical needed to install the System not specifically described in the and/or plumbing systems. System section on the first page of this Agreement. u) "System"—The solar energy system and/or other equipment, c) "Business Day" — Any day of the week other than Sunday. system(s), and improvements as shown on the Final System The following holidays are not Business Days: New Year's Design and that will be installed at the Site. Day, Martin Luther King, Jr.'s Birthday, President's Day, v) "System Lock-In" — The date and time upon which the Final Memorial Day, Independence Day, Labor Day, Columbus System Design is deemed accepted by Customer. Day,Veterans'Day,Thanksgiving Day,and Christmas Day. w) "Total Price"—The cost of the System as shown on the first d) "Change Order"—Any amendment to this Agreement and/or page of this Agreement. changes to the System,reduced to writing and signed by both 2) Final System Design Process parties. a) Within fourteen(14)days of the Effective Date, Installer shall: e) "Commissioning"—In the case of a photovoltaic solar energy i) Conduct a Solar Site Assessment, if one has not already system,connection of the System to the electric utility grid. been conducted. Customer will provide access to the f) "Contract Date"—The first Business Day after the later of(i) Site at a mutually acceptable time in order to conduct the the expiration of the Right to Cancel; and, (ii) the System Solar Site Assessment. Lock-In Date. ii) Based upon the information obtained during the Solar g) "Customer" —The person(s) named in the Customer section Site Assessment, confirm the Preliminary System, and if on the first page of this Agreement that has contracted with necessary for technical, structural, dimensional and/or Installer for the installation of the System as defined herein. other reasons,alter the Preliminary System. h) "Effective Date"—The first Business Day after the expiration iii) Prepare and deliver to Customer the Final System of Customer's Right to Cancel. Design,which shall include at least: I) "Final System Design" — A plan based upon Customer's (1)The quantity, manufacturer, and model of the PV needs and Site specific criteria prepared after the Solar Site Modules or Thermal Panels; Assessment that, upon System Lock-In, will become the (2) The quantity, manufacturer, and model of the PV System to be installed at the Site. Inverter,if applicable; j) "Final System Price" —The cost of the System as shown on (3) Description of other components and equipment not the Final System Design. included in the Balance of System; k) "Installer"—BlueSel Home Solar, Inc.with a principal office at (4)The Final System Price;and, 600 West Cummings Park, Suite 4200, Woburn, MA 01801, (5) The projected PV Production of the System in the which address shall be used for all written notices. first year after installation of the System, if 1) "Mailing Address"—The address to which any notice,invoice, applicable. or other written communication provided to Customer should b) If elected on the first page of this Agreement, Final System be sent. Design may be delivered by email, of which Customer shall m) "Permits" — Namely, the building permit, electrical permit, acknowledge receipt. and/or plumbing permit issued by the local permit issuing c) If email delivery is not so elected, Final System Design may authority. Other permits (e.g., conservation commission, be in person, by regular mail, or by another means agreed planning board, historic commission, etc.), are not usual, and upon by the parties. Customer shall acknowledge receipt of are not included in this definition,but may be required. the delivery of the Final System Design. n) "Preliminary System Design" — The solar energy system d) If either, and/or other equipment, system(s), and improvements, i) the Final System Price is more than the Total Price;or, described in the Preliminary System Design section on the ii) the projected PV Production of the Final System Design first page of this Agreement,and the Balance of System items is less than 95%of the PV Production of the Preliminary as defined herein. System as shown on the first page of this Agreement, o) "Project Completion" — Installation of the System and final then System Lock-In shall occur at 11:59 p.m.on the fifth(5`h) approved inspection of the System as required by Permit Business Day after delivery of the Final System Design to issuing authorities, typically within four to five weeks after Customer. Project Start Date. e) If Final System Design differs from Preliminary System p) "Project Start Date" —The date on which Installer begins to Design in either of the manners described in Section 2)d) install the System. above, Customer may cancel this Agreement in a writing q) "Right to Cancel" — The option of Customer to cancel this mailed to Installer, postmarked prior to System Lock-In. To Agreement, for any reason, until midnight of the third insure such cancellation is properly received, it is also business day after the Agreement Date, as described in the suggested that Customer inform Installer of such cancellation Notices and Signatures section on the first page of this by telephone or email prior to System Lock-In. Agreement, and as described in the Notices of Cancellation f) If Final System Design does not differ from the Preliminary form delivered to Customer with this Agreement. System in either of the manners described in Section 2)d) Residential Solar Energy System Installation Agreement The terms of this agreement are contained on more than one page. Page 2 of 5 above,then System Lock-In shall occur upon delivery of Final excluded from access to the Guarantee Fund under MGL System Design to Customer(which will, in all cases, be after 142A• the expiration of the Right to Cancel). g) Customer understands and agrees that Installer may include g) Unless Customer cancels this Agreement prior to System Customer's name, Site Address, a description of the System, Lock-in as described herein, if any terms, price, and/or items costs, energy savings, and other information relating to the included in the Final System Design differ from those on the System in reports, studies, testimonials, Web sites, and first page of this Agreement,those terms, price, and/or items marketing materials. in the Final System Design shall govern. 5) Installer Representations h) If Customer cancels this Agreement pursuant to Section 2)e) a) Installer Federal Employer ID Number.47-2714223 above, the obligations, rights, and duties of each party are b) Installer Massachusetts Home improvement Contractor canceled and this Agreement shall be of no further effect. Registration Number: 166151,expires April 29,2016 i) Upon System Lock-In, this Agreement, including the Final c) Installer Massachusetts Construction Supervisor License System Design shall become binding upon each party, and Number:5813,expires January 3,2016 may be amended only by a Change Order. d) Unless noted otherwise,this Agreement shall not create a lien 3) Installer Obligations and Responsibilities or other security interest in the Site. a) Within fourteen days of System Lock-In, Installer will file e) The System will: applications for the Permits, Grid Interconnect Application, i) Comply with all manufacturers'requirements, and other paperwork related to the installation of the System, ii) Be installed according to manufacturers' recom- and it shall be the obligation of Installer to obtain these. mendations, b) Installer shall provide and install all equipment, components, iii) Meet all applicable requirements of the applicable current and materials included in the System, as well as the Balance state building code,and the National Building Code 2008. of System, in a professional manner according to standard iv) Comply with your electric utility company's interconnection industry practices. agreement c) Project Start Date shall be within thirty(30)days of receipt of v) Utilize photovoltaic modules certified by a nationally all permits, grid interconnect authorization, verification of recognized testing laboratory as meeting the requirements receipt of deposited funds, but not before the signing of this of UL 1703 all,as applicable. Agreement and transmittal to Customer a copy of this 6) Customer Representations Agreement signed by all parties. a) Customer is authorized to contract with Installer to install the d) Project Completion is typically within five (5) weeks after System. Project Start Date. b) Customer warrants that the statement concerning whether the e) Delays beyond the control of Installer such as, but not limited Site is the Principal Residence or not the Principal Residence to, inclement weather, shipping delays, delivery delays, of Customer is true and accurate. Installer may rely upon this structural analysis and/or improvements, and lack of access statement in determining whether to collect sales tax on the to the Site, may affect time periods identified, and such System.Customer is responsible for any sales tax owed. delays shall not be grounds for breach of this Agreement by c) Customer shall make the Site available to Installer at mutually Installer. acceptable times for the purpose of installing the System,and f) Installer shall, upon request of Customer, provide evidence of for any purpose related to the installation. insurance for general liability and workmen's compensation. 7) Information About Home Improvement Contractors 4) Customer Rights,Obligations,and Responsibilities a) All home improvement contractors and subcontractors shall a) The fee(s) for all permits are the responsibility of Customer be registered and any inquiries about a contractor or and shall be billed to Customer by Installer separately. If subcontractor relating to a registration should be directed to: 'Permits Included" is checked in the affirmative on the first Office of Consumer Affairs and Business Regulation page of this Agreement, the cost for a building permit, Ten Park Plaza,Suite 5170 electrical permit, and plumbing permit is included. Other Boston,MA 02116 permit fees remain the responsibility of Customer. Phone:(617)973-8700 b) If required by municipal permit issuing authorities,a structural b) if you want to verity the registration of a contractor or if analysis of the Site may be conducted by a professional you have questions or need additional information engineer. The cost of the structural analysis and required specifically about the contractor registration component of improvements are the responsibility of Customer. the Home Improvement Contractor Law,contact: c) In the case of a Cash purchase, as may be indicated on the Director of Home Improvement Contractor Registration first page of this Agreement, Customer shall comply with the Bureau of Building Regulations and Standards Payment Schedule. One Ashburton Place,Room 1301 d) Customer shall cooperate in a timely manner with all requests Boston,MA 02108 of installer to complete and/or sign any documents related to Phone:(617)727-3200 the installation of the System, including, but not limited to, c) For assistance with informal mediation of disputes or to permit applications, Grid Interconnect Application, and register formal complaints against a business,call documents requested by financing entity,as applicable. Consumer Complaint Section e) In the event that Customer is financing the installation of the Office of the Attomey General System and the Final System Price should change in (617) 727-8400 accordance with the terms of this Agreement, Customer agrees to perform all steps required of the financing entity needed to perfect the financing of the System. f) Should Customer secure any construction-related permits, or deal with unregistered contractors. Customer shall be Residential Solar Energy System Installation Agreement Page 3 of 5 The terms of this agreement are contained on more than one page. �' ,.. y"wrY, n,t rr �✓sf f r jl I"; I t r`jr'`t'�t�� 7 . � .. r rr loi [letn ytirn, " fr tlaln i by r Cation and customer ff c any gut f- "ac c t` �t fail t r ?► suit arbitration ,d in behalf, a 1 ) MisceflanooUS r r t a The caption of the sections of this r* t r " convenience and shall not e cortrued "AS 000 tn�t r: language of the Agreement. ate. sells b)' the lags of the Commonwealth of Maschu 'saljaP ( , The signatures of t parties above apply only to the in interpreting and enforcing this,Agreement, t t f ,e parties to alternate dispute resolution initiated by c)` Should any section or;sections of the Agreerx nt be d m U Iler, Cummer may initiate alternative depute resolution riven unlawful or unenforceable, the remaining sections h ore this section is not signed separately by the parties, remain in full force. g); Disclaimers a) Although Installer has endeavored to provide Customer with Your Elue5el Horne Solar, Inc,Sales Representative is; accurate projections and estimates and has based all estimates and projections of PV Production.__electric utility -- Name-.Dave Judelson company rates, the value of solar renewable energy credits, and other financial items are not guaranteed or assured Phone 781-799-4743 Customer is encouraged to conduct its oven research on these matters. Email djudelsan@biuesel.cam Lt) 'Financial incentives for solar energy systerns change frequently. Customer's qualification for and receipt of incentives depend upon numerous factors, includinri, but not DO NOT 51Cht THIS AGREEMENT IF ANY SPACES ARE BLANK. limited to Customer's approval for the program, availability of funding, and Customer's tax situation All financial incentives THE REMAINDER OF THIS PAGE IS INTENTIONALLY BLANK. discussed or presented in other documents by Installer are presented as estimates for general information and are not intended as tax or financial advice Installer strongly recommends that you consult your financial and tax :advisors to determine the applicability of these incentives to your project and individual situation. Ilei) Warranty Terms and Conditions a) iInstaller shall repair and replace components of the system during the ten (10) years following the Project Completion in the event of i) Defective workmanship, ai) system breakdown except for the components of a data acquisition system, iii) Degradation in electrical output of a solar,,photovoltaic panel of more than the manufacturer's rated maximum degradation during the Installers warranty period. j The warranty covers the System, including PV modules and ioveind provides for no-cost repair or replacement of ; smor,system components, including any associated mar"" orris .,labor charges will apply after the 10-year ; farrrrt period.r r? yst -In, Customer may only terminate this t �� f r y far substantial breach of a material section of this s �jsff ,ad firrnlnaftnrl under thisSection 1€l)b, f{ 7 ' Fly r rr trst frtat fy lnstalisr in writing cif its intentte� acrd"rlearty ldritify' spbtaralaal Iar each 3 ���7"yrr,✓y 1`r Jfrfr p :. ." f, � ✓ i„frrr r1"�r�'�°�+h�l"r �� 2�r f r.` a .? �:-fi �;r�;�{� �F„ �>>_,'_r_. a �r>�,r��✓r7N�may_.n, r__,. �.r .4 }J.. _ [You are being provided with two copies of this form, one for you to use, if you choose to cancel,and one to keep] NOTICE OF CANCELLATION Customer(s): David b Ph ry lis IaCOviello Site Address: iso Liberty.St.,_�N/. Andover_, MA ,01845 Date of Transaction: MAX You may cancel this transaction, without any penalty or obligation, within three business days from the above date. If you cancel, any property traded in, any payments made by you under the agreement, and any negotiable instrument executed by you will be returned within ten business days following receipt by the seller of your cancellation notice,and any security interest arising out of the transaction will be cancelled. If you cancel,you must make available to the seller at your residence, in substantially as good condition as when received,any goods delivered to you under this agreement; or you may if you wish, comply with the Instructions of the seller regarding the return shipment of the goods at the seller's expense and risk. If you do make the goods available to the seller and the seller does not pick them up within twenty days of the date of your notice of cancellation, you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller, or if you agree to return the goods to the seller and fail to do so, then you remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice or any other written notice,or send a telegram to: BlueSel Home Solar, Inc.,600 West Cummings Park,Suite 4200,Woburn, MA 01801, not later than midnight on: 2�2,�.� 120, • 1 hereby cancel this transaction. Date: — Customer's Signature [You are being provided with two copies of this form, one for you to use, if you choose to cancel,and one to keep.] NOTICE OF CANCELLATION Customer(s): David & Phyllis lacoviallo Site Address: 150 Liberty St. , N_ Andover, MA 01845 Date of Transaction: +9//- You may cancel this transaction, without any penalty or obligation, within three business days from the above date. If you cancel, any property traded in, any payments made by you under the agreement, and any negotiable instrument executed by you will be returned within ten business days following receipt by the seller of your cancellation notice,and any security interest arising out of the transaction will be cancelled. If you cancel,you must make available to the seller at your residence,in substantially as good condition as when received,any goods delivered to you under this agreement; or you may if you wish, comply with the Instructions of the seller regarding the return shipment of the goods at the seller's expense and risk. If you do make the goods available to the seller and the seller does not pick them up within twenty days of the date of your notice of cancellation, you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller, or If you agree to return the goods to the seller and fail to do so, then you remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice or any other written notice,or send a telegram to: BlueSel Home Solar, Inc., 600 West Cummings Park, Suite 4200,Woburn,MA 01801, not later than midnight on: - !Z-1 ,20_/!5_� . I hereby cancel this transaction. Date: Customer's Signature r r • • � r r � 20% EFFICIENCY SunPower E20 panels are the highest efficiency panels on the market today, SERIES providing more power in the same amount of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest- efficiency panels with the highest-efficiency inverters, maximizing system output REDUCED INSTALLATION COST More power per panel means fewer panels per install. This saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique Maxeon'cell THE WORLD'S STANDARD FOR SOLAR' technology and advanced module design ensure industry-leading reliability SunPowerTM E20 Solar Panels provide today's highest efficiency and performance. Powered by SunPower MaxeonTM cell technology, the E20 series provides panel conversion efficiencies of up to 20.1%. The E20's low voltage temperature coefficient, anti-reflective glass and exceptional low-light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% ..., d. a'. 15% . ..._. . . 10% 5% THIN FILM CONVENTION........._ _....... „m.,_.,..... ,....... AL p AXEONTM CELL SERIES SERIES SERIES TECHNOLOGY Patented all-back-contact solar cell, providing the industry's highest efficiency and reliability C US M'iii Zr � ,.,:,����✓ i,,,/W„ i ,,i,,,,/� ,,,,,////„i�6„��aci� ,///, 1 ��il,/,, �,�,,,,,.//✓i,/////i,,,,�///ll�/l//�/O��riid �orr���rr,,%l//.//�'Gl,�,, // ii MODEL: SPR-327NE-WHT-® ELECTRICAL DATA IN CURVE Measured at Standord Test Conditions(STCJ inodi...of I000w/ms,AM 1.5,-d cell Nutperat r 25°C 7 Ef�4�wL Vsf�arF'rIR.HtT f Peak Power(+5/-3%) Pmax 327 W 6 t000w/m' Cell Efficiency n 22.5% 5 Panel Efficiency n 20.1 % a 4 Wkw/, r c Rated Voltage VmPp 54.7 V C 3 wtW/t l Rated Current Impp 5.98 A 2 Open Circuit Voltage Voc 64.9 V 1 200 VJ(ma Short Circuit Current Isc 6.46 A 0 Maximum System Voltage UL 600 V 0 10 20 30 40 50 60 70 Voltage(1/) Temperature Coefficients Power(P) -0.38%/K Current/voltage characteristics with dependence on irradiance and module temperature. Voltage(Voc) -176.6mV/K Current(Isc) 3.5mA/K TESTED OPERATING CONDITIONS NOCT 45'C+/-2'C Series Fuse Rating 20A Temperature -40'F to+185'F(-40'C to+ 85'C) Max load 113 psf 550 kg/m2(5400 Pa),front(e.g.snow) Grounding Positive grounding not required W/specified mounting configurations MECHANICAL DATA 50 psf 245 kg/m2(2400 Pa)front and back (e.g.wind) Solar Cells 96 SunPower Maxeon7h1 cells Front Glass High-transmission tempered glass with Impact Resistance Hail: (25 mm)at 51 mph (23 m/s) anti-reflective(AR)coating Junction Box IP-65 rated with 3 bypass diodes - Dimensions: 32 x 155 x 128 mm WARRANTIES AND CERTIFICATIONS Output Cables 1000 mm cables/Multi-Contact(MC4)connectors Warranties 25-year limited power warranty Frame Anodized aluminum alloy type 6063 (black) 10-year limited product warranty Weight 41.0 lbs(18.6 kg) Certifications Tested to UL 1703.Class C Fire Rating DIMENSIONS 2X 1,.0[.43] MM (A)-MOUNTING HOLES lgl-GROUNDING HOLES 30[1,8] 2x 577122.70] 180[7.071 (IN) 12X 06.6[.26] lOX 04.2[.17] 322112.69] 4X 230.8[9.09] BRIH END a 1559[61.39] 46[1.81] —� (A) 915[36A21 . 1200[47.24] 12[.471 1535[60.45] Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. @2011 SunPower Corporation.SUNPOWER,the SunPower Logo,and THE WORLD'S STANDARD FOR SOLAR,and MAXEON are Irademarks or registered tiademorks s u n p owe rco r p.c 0 m of SunPower Corporation in the US and other counlriee as well.All Rights Reserved.Specifications included in this dotasheet are subject to change without notice. Document#00665484 Rev'8/LTR-EN CS 11316 '.,, FORTH ---ftdoV P town of ® T , LAKE h ver, ass, hcop COCKICNEWICK Pvs- BOARD OF HEALTH Food/Kitchen ERMIT T�� LD Septic System ��..�t... ,,,,,,,,,,,,,,,, , , ,, BUILDING INSPECTOR THIS CERTIFIES THAT .......... .... ....... ... ... .�...... has permission to erect . buildings on ..lt1 .'' +. Foundation ......................... .................... a .... .................. Rough tobe occupied as ....`.a. ..... ........ *1^1, ..A......................................................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 M. NT S ELECTRICAL INSPECTOR ® UNLESS CONSTRUCTIO Rough Service r� .... ..`.................................................. Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Reguired to Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approvedy the Building Inspector. Burner Street No. Smoke Det. t r "%%'�h/ i' 'i"""'�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIII IIIIII" "I 6°''����"' SPS THE WORLD'S ONLY SECURE POWER SUPPLY t l Certified Innovative Powerful Flexible • UL 1741 and 16998 compliant +Secure Power Supply provides •97.2%maximum efficiency •Two MPP trackers provide • Integrated AFCI meets the require- daytime power during grid outages +Wide input voltage range numerous design options ments of NEC 2011 690.11 +Shade management with OpliTrac •Extended operating Global Peak MPP tracking temperature range SUNNY BOY 000TL-US / 380OTL-U / 4000TL-U / 000TL-US / 6000TL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000T1-US represents the next step in performance for UL certified inverters. Its transformerless design means high efficiency and reduced weight. Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTm Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power Supply feature provides � daytime power in the event of a grid outage.High performance,flexible design and innovative features make the Sunny Boy TL-US series the first choice among solar professionals. o0 w o� "tier rntPa91 --------------------------------------------------------- --------------------------------,Efficiency curve SUNNY BOY 5000TL-US --------------------------------- Accessories --------------------------------------------------------- 98 Speedwire/Webconnecl RS485 interface interface DMA85CB-US-10 96 ...... SWDM-US-10 94 92 '0 97 n kil fE 90 Fan 95 88 E1.(V,-175V), Eta N,=400 W 86 Et.IV,=480 V)I r 0.0 0.2 0.4 0.6 0.8 1.0 i Output power/Rated power ; 0 Standard feature 0 Optional feature Not available t -------------------------------------------------------------------------------------- -------- ------- Data at nominal conditions Technical dataSunny Boy 4000TL-US Sunny Boy 5000TL-US Sunny Boy 6000TL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max.usable DC power(@ cos(p=1) 4200 W 5300 6300 W Max.DC voltage 600 V 600 V 600 V Rated MPPT voltage tango 175-480 V 175-480 V 210-480 V MPPT operating voltage range 125 V-500 V 125 V-500 V 125 V-500 V Min.DC voltage/start voltage 125 V/150 V 125 V/150V 125 V 150 V Max.input current/per MPP tracker 24 A/15 A 30 A/15 A 30 A 15 A Number of MPP trackers/strings per MPP tracker 2/2 Output(AC) AC nominal power 4000 W 4550 W 5000 W 5200 W 6000 W Max.AC apparent power AOOO VA 4550 VA 5000 VA 5200 VA 6000 VA Nominal AC voltage/adjustable 208 V/• 240 V 0 208 V/o 240V/0 208 V/0 240 V AC voltage range 183-229 V 211 -264 V 183-229 V 211 -264 V 183-229 V 211 -264 V AC grid frequency;range 60 Hz 59.3-60.5 Hz 60 Hz 59.3-60.5 Hz 60 Hz 59.3-60.5 Hz Max.output current 20A 22 A 25A Power factor(cos(p) I I Output phases/line connections 1/2 1/2 1/2 Harmonics <4% <4% <4% Efficiency Max.efficiency 96.8% 97.2% 96.8% 97.1% 97.0% 97.4% CEC efficiency 96% 96.5% 96% 96.5% 96.5% 97.0% Protection devices DC disconnection device 0 DC reverse-polarity protection Ground fault monitoring/Grid monitoring 0/0 AC short circuit protection 0 All-pole sensitive residual current monitoring unit 0 y U Arc fault circuit interrupter(AFCI)compliant to UL 16998 0 Protection class/overvoltoge category I/IV General data Dimensions(W/H/D)in mm(in) 490 519 185 (19.3 20.5 7.3) DC Disconnect dimensions(W/H/D)in mm(in) 187/297/190 (7.4 11.717.5) �2 Packing dimensions(W/H/D)in mm(in) 617/597/266 (24.3 23.5 10.5) DC Disconnect packing dimensions(W/H/D)in mm(in) 370/240/280 (14.6 9.4 11.0) o Weight/DC Disconnect weight 24 kg (53 lb)/3.5 kg (8 lb) Packing weight/DC Disconnect packing weight 27 kg (60 lb)/3.5 kg (8 lb) Operating temperature range -40*C...+60*C (-40*F...+140'F) Noise emission(typical) <25 dB(A) <29 dB(A) <29 dB(A) Internal consumption at night <I W <I W <I W Topology Transformerless Transformierless Tronsformerless Cooling concept Convection Convection Active Cooling Electronics protection rating NEMA 3R NEMA 3R NEMA 3R Features Secure Power Supply 0 0 0 Display:graphic 0 0 0 Interfaces:RS485/Speedwire/Webconnect 0/0 0/0 0/0 Warranty:10/15/20 years 6/0/0 @/0/0 6/0/0 Certificates and permits(more available on request) UL 1741,UL 1998,UL 1699B,IEEEI 547,FCC Part 15(Class A&B),CAN/CSA C22.2 107.1-1 NOTE:US inverters ship with gray lids Type designation SB 4000TL-US-22 SB 5000TL-US-22 SB 6000TL-US-22 Toll Free+1 888 4 SMA USA www.SMA-America.com SMA America, LLC Ak ROOF ACCESSORY SYSTEMS SOLAR MOUNTING SYSTEMS e� of M 5/16" 1r W �1✓"lw`�f ax�rt�,„ M � aY&✓aur�LJirJIJm�ur v ''..... 21/2" . v 3" 1.57" 1" 3/4" Q F. EN NM �p 'Dimensions shown are in inches unless otherwise noted IREM 6063 T68 Aluminium Mill finish AIloyaJ U (lbs) Uplift:aoo Downforce:400 Shear:180 Simpson SDS 1/4"Fastener,L=3.5",4.5",6"(SDS25312-SS,SDS25412,SDS25600) �i Standard Roof Mount Flashing(77000501) Socket Head Cap Screw M8 x VAR(15100018,19,20,21,22,23,38,58) Clamping Plate(72201701) Clamping Plate Adjustable(74022601) Cotj�a�ibfe toGm#1,r�y R )I,, All TRA-MAGE SunFIXINGS rails(22x65,40x40,40x60)as well as other major brands 10 Years(See warranty documentation for conditions) TRA-MAGE, INC. 1657 SOUTH 580 EAST,AMERICAN FORK, UT,84003 OTRA-MAGE,Inc.,2011 PH: (800)606-8980 1 sun.tra-mage.com 3/13/20II SDS fkSDWood Screws � vmwvxetr8Dgde.co0 - SDS & SD Wood Screws The Simpson E8nong'Te@ Strong-DdveOoon»w(SDS) ioe1/4" diameter structural wood screw ideal for\rarious connector installations as well as wood-to-wood ^ applications. It installs with no predrilling and has been extensively tested in various . applications. The new SDS is improved with a patented easy driving 4CUTTM tip and acorrosion resistant duub|e'baniercoating. � � ..v The SD8#8x1 1/4'wafer head screw iaideal for miscellaneous fastening applications. The needle point ensures fast starts and deep#2 Phillips drive reduces Load Tables cam-out and stripping. Gallery ofimages Also see: Code Reports Drawingo w Catalog Page • Related Categories Technical Bulletins w Fliers Featured Literature SIDS Features: Help for downloads w The patented 4CUTtip has esquare core and serrated threads toreduce installation torque and make driving easier with no predrilling and minimal wood splitting. ° A double-barrier coating finish pro\Ades corrosion resistance equivalent to hot-dip galwanization. Now one screw can handle interior, exterior and certain press ure-treated wood applications. See Corrosion Information. w 3/8" hex washer head is stamped with the No-Equal sign and fastener length for easy inclentification after installation. * Suitable for ledgers:The SDS is suitable for installing ledgers tomeet the requirements of the building codes. P|aoeo for spacing and other information. Material: Heat-treated carbon steel; Type'318stahnless steel STAINLESS STEEL:The SDS Strong-Drive 1A"wood screw line has expanded to include stainless-steel SDS screws in1 1/2'kz31/2"lengths,suitable for fastening Simpson Strong-Tie stainless-steel products.Offering the same ooey'drivin8.split- reducing installation of the standard SIDS screw,these screw s are made from type 316 p|it-reduoinginotoUationofthoetondordGDGocrmm.th000sunewoammodefmmtype81O stainless steel.The new stainless-steel SIDS screws are appropriate for higher- exposure onvironmantswhomnaximumou/mainn'muiotonueismquimd. Finish: SDS - New clouble-barrier coating. SDS screws may also be available yellow zinc dichromate or HDG (Not all sizes are available in all coatings - for product availability and ordering information). GD8x1.2G' Electro Galvanized. WARNING:Industry studies show that hardened fasteners can experience performance problems inwet orcorrosive environments.Accordingly,the GD8should beused indry, interior,and noncorrosive environments only. Installation: • Strong-Drive Screw Installation for LVL, PSL and LSL * Multi-Ply Wood Trusses Applications: Two-Ply 4)(2 Floor Trusses o Multi-Ply Wood Trusses Applications: Girder Trusses 3/18/2011SDS &SD Wood Screws .. ....._... _.. .. _.. _. ._...... .. . _ ... w._...... ORSF Allowable Loads' SPF/HF Allowable Loads' size Model Length Fasteners w Shear(100) Withdrawal$ _ Sheat(100) Withdrawal' (In.) NoLength per Wood Side Plate Steel Side Plate (,100) Wood Side Plate Steel Side Plate (100) (in.) Cartons µ.. _ _ �_ _. .... 1" " 1V" 16 ga 1d ga& 10 ga or Wood ar Sleet 1,,7, 13S 18 0a t4 ga& 10 ga or Woad ar Steat SCL 12 ga Greater Side Plates SCL 12 ga l theater side Plates X 16 SDS25112SS 1 1549 — 1 2 50 f 250 250 170 — — 180 180 ! 180 120 _. . _.. .., 1... __... ._w. da X 2✓i 50525212SS 1a 1iC44 1 25t1 ' S4t 42t1 'A X2 SDS252008S VA 1300 250 29� 290 255 135 � 180 210 � 210 150 T ,. 4 284 , to x 3 MS2530OSS 2 950 280 259 � 420 420 345 200 180 300 f 300 240_.._..... ✓ax3�,z 50525312 2r�i 900 34 3 0 40 2 50 42db 420 385 245 245 180 340 300 27p _ _ _ .. 1. Screw s may be provided w ith the 4CUT or Type 17 tip. 2. SDS screw s install best w ith a low speed 1/2"drill w ith a 3/8"hex head driver. 3. All applications are based on full penetration into the main member. 4. Allow able loads are show n at the w ood load duration factor of CD=1.00.Loads may be increased for load duration by the building code up to a CD=1.60. 5. Withdraw al loads shown are in pounds(lbs.)and are based on the entire threaded section installed into the main member.If thread penetration into the main member is less than the Thread Length as show n in the table,reduce allow able load by 172 lbs.x inches of thread not in main member. Use 121 lbs./inch for SPF. 6. Fasteners per Carton represent the quantity of screws w hich are available in bulk packaging.Screws are also available in mini bulk and retail packs.Refer to pricing information. 7. LSL w ood-to-w ood applications that require 4 1/2",5",6"or 8"SDS screw s are limited to interior-dry use only. 8. SD8x1.25 requires 3/4"minimum penetration.DO NOT USE SD8x1.25 wood screws w ith structural connectors unless specified and stated in this catalog. Code rip _s( Fs); Tnext .top IAPMd ES IMES ESR CITY OF LOS ANGELES STATE OF FLORIDA IMES NER, ICC-ES ER IMES ES ER SM1.25 No code listing:Please contact usfortest data. SDS See specific model numbersfor code listings. SDS25112 ESR-2236 RR25711 FL9589 SDS25134 ESR-2236 RR25711 FL9589 i SDS25200 ESR-2236 RR25711 FL9589 SDS25212 ESR-2236 RR25711 FL9589 SDS25300 ESR-2236 RR25711 FL9589 SDS25312 ESR-2236 RR25711 FL9589 SDS25412 ESR-2236 RR25711 FL9589 SDS25600 ESR-2236 RR25711 FL9589 SDS25800 ESR-2236 RR25711 FL9589 Dralnr n9s: To download drawings,right-click or Ctrl-click on the link,then choose"Sam Target As..." vnext ,,top Download the Simpson Strong-Tie AutoCad®Menu,w hich allows you to insert Ortho views directly into your AutoCAD draw ing. OR'1 HOGPA PHIL SD8X1/4: DWG I DXF SM1.25 SD8X1/4 front view:DWG I DXF None for this model SD8X1/4 top view: DWG I DXF SDS Screw View 1: DWG I DXF SDS Screw View 2: DWG I DXF SDS None for this model SDS Screw View 3: DWG I DXF SDS Screw View 4: DWG I DXF strongtie.com/products/.../screws.asp 3/4 3/18/2011 SDS &SD Wood Screws SDS Screw View 5: DWG I DXF SDS25112 None for this model None for this model SDS26134 None for this model None for this model SDS25200 None for this model None for this model SDS25212 None for this model None for this model SDS25300 None for this model None for this model SDS25312 None for this model None for this model SDS25412 None for this model None for this model SDS25600 None for this model None for this model SDS25800 None for this model None for this model Catalog Pages(PRFs). Atop C-2011 (Wood Construction Connectors), page 28 Order free catalogs by mail Related Categories: Atop Specialized Fasteners (wood Construction) Fasteners &Adhesives for Home Products (DIY) Technical Bulletins(PDFs) Atop Strong-Tie Screw Applications, Limit States Design, for Canada only Fliers(PRFs): Atop Strong-Drive® Screws Deck Framing Connection Guide You can order this flier by mail. Strang-Drive® SDS Screw for Deck Ledgers Featured Literature: Atop Deck Framing Connection Guide Deed heli with downloads Atop Printed March 18,2011 fromhttp://www.strongtie.conVproducts/connectors/screws.asp ©2011 Simpson Strong-Tie® strongtie.com/products/.../screws.asp 4/4 The Commonwealth of Massachusetts UV Department of Industrial Accidents I Congress Street, Suite 100 Boston,MA 02114-2017 www.mass.gov/diu Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):United Solar Associates LLC Address:452 Pleasant Street, Second Floor City/State/Zip:Malden, MA 02148 Phone#:855.786.1776 Are you an employer?Check the appropriate box: Type of project(required): 1.E]I am a employer with 5 employees(full and/or part-time).* 7. ❑New construction 2.7 I am a sole proprietor or partnership and have no employees working for me in 8. FIRemodeling any capacity.[No workers'comp.insurance required.] 9. El Demolition 3.71 am a homeowner doing all work myself.[No workers'comp.insurance required.]t 10 n Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.F-1 Plumbing repairs or additions 5.❑I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13. Roof repairs These sub-contractors have employees and have workers'comp.insurance.t 14.�✓ Other Solar Install 6.❑We are a corporation and its officers have exercised their right of exemption per MGL C. 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. #Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp,policy number. Iainan employer that isproviding workers'compensation insurance for my employees. Below is the policy andjob site information. Insurance Company Name:Travelers Policy#or Self-ins.Lic.#:7PJUB-5B50763-8-14 Expiration Date:07/23/2015 Job Site Address:150 Liberty St City/State/Zip:Andover, MA 01845 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under tit paii,s and enalties ofperj ry that�the information provided above is true and correct. rlSignature: ( Date: -i d Phone#:855.786.1776 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: From: 6513107911 Page: 2/2 Date: 7/23/2014 7:14:02 AM CERTIFICATE OF LIABILITY INSURANCE DATEfMNUDD/YYYYI T R IFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require and endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: LOPRIORE INS AGENCY INC PHONE FAX 426 MAIN STREET SUITE 2 (A,'C,No,Ext): (A1C,No): E-MAIL STONEHAM,MA 02180 ADDRESS: j SMTK INSURER(S)AFFORDING COVERAGE NAIC# INSURED INSURER A: TRAVELERS PROPERTY CASUALTY COMPANY OF AMERICA UNITED SOLAR ASSOCIATES LLC INSURER B: INSURER C: INSURER D: 114 BOYLSTON STREET INSURER E: MALDEN,MA 02148 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: T1419 IS TO CE 71FY THAT THE POLICES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED_NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN.714E INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADD SUB POLICY EFF DATE POLICY EXP DATE LTR TYPE OF INSURANCE L R POLICY NUMBER (MMXDD\YYYY) (MM OD`LYYYY) LIMITS GENERAL LIABILITY AC-I OCCURRENCE $ COMMERCIAL GENERA-LIABI-rrY DAMAGE TO RENTED $ CLAIMS MADE F]OCCUR. PREMIPEP(Ea nnnurenne) ED EXP(Any one person) $ ERSCNAL R ADV IN.IIJRY GEN'L AGGREGATE LIMIT APPLIES PER: 3ENERAL AGGREGATE $ VD POLICY [:]PROJECT[::]LOC IRODUCTS-COMP/OP AGG $ AUTOMOBILE LIABILITY COMBINED SINGLE $ ANY AUTO LIMIT(Ea accident; ALL OWNED AUTOS BODILY INJURY $ SCHEDULE AUTOS (Per person) HIRED AUTOS BODILY INJURY $ (Per accident) NON-OWNED AUTOS PROPERTY DAMAGE $ (Per accident) UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DEDUCTIBLE $ RETENTION $ $ WORKER'S COMPENSATION AND =STAT RY OTHERA EMPLOYER'S LIABILITY YIN UB-SB507638-14 07/23/2014 07/2312015X ANY PROPER[TO R/PARTNER/EXECUT VE [::] NIAE.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 Ityes,cescrlbeuncer E.L.DISEASE-POLICY LIMIT $ 1,000,000 DFSCRIPTION OF OFFRATK7)NS Irinw DESCRIPTION OF OPERATIONS/LOCAl10NS1VEHICLES;RES7RIC11ONSiSPECIAL ITEMS TMS REPLACES ANY PRIOR CERT IFIC.ATB ISSUED TO THE CERT IFICATH HOLDER AFFECTING W ORKHRS COMP C04-ERAGE. CERTIFICATE HOLDER CANCELLATION TOWN OF NORTH ANDOVER-BUILDING DEPARTMENT SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED 1600 OSGOOD STREET IN ACCORDANCE VV17H THE POLICY PROVISIONS. AUTHORIZED R EPRESENT4j:,VE .::.. NORTH ANDOVER,MA 01845 ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD 1988-2010 ACORD CORPORATION. All rights reserved. This fax was received by GFI FAXmaker fax server. For more information,visit: http:l/www.gfi.com DATE(MM/5DD/YYYY) 5/20/2010ERTIFICATE OF LIABILITY INSURANCE ''.... THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. Astatement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: ASSET ONE INSURANCE SERVICESH NE Ext: 714 625-8204 (A/c,No):(714)625-8290 575 Anton Blvd 3rd Fl ADDRESS: aagopian@gmil.com Costa Mesa, CA 92626 INSURER(S) AFFORDING COVERAGE NAICH OE66207 INSURER A: Westchester Surplus Linea Insurance Company '... INSURED United Solar Associates, LLC INSURER B: '.. INSURER C 300 Brickstone Square. , Suite 201 INSURER D: Andover, MA 01810 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER LIMITS LTR INS D POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) $ 50 00 '..... CLAIMS-MADE FxI OCCUR MED EXP(Any one person) $ 10,000 A 627527966 001 11/10/14 11/10/15 PERSONAL BADVINJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OPAGG $ 1 000 OOQ riPOLICY rx-1 PE OT 0 LOC $ AUTOMOBILE LIABILITY Ea accident $ ANYAUTO BODILY INJURY(Per person) $ ALLOWNED SCHEDULED BODILY INJURY (Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS (Per accident) UMBRELLA LIAB OCCUR EACH OCCURRENCE $ 5,000,000 EXCESS LIAB 627527966 001 11/10/14 11/10/15 ! A }( CLAIMS-MADE AGGREGATE $ 5,000,000 1 DED RETENTION $ $ -WORKERS COMPENSATION WC STATU- AND EMPLOYERS'LIABILITY YIN X TORY LIMITS ER j ANY PROPRIETORIPARTNERIEXECUTIVE ❑ NIA E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (AttachACORD 101,Additional Remarks Schedule,if more space is required) Certificate Holder is named Additional Insured. CERTIFICATE HOLDER CANCELLATION Town of North Andover SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Attn: Building Department THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 1600 Osgood Street ACCORDANCE WITH THE POLICY PROVISIONS. Building 20, Suite 2035 North Andover, MA 01845 AUTHORIZED REPRESENTATIVE P: 978-688-9545 F: 978-688-9542 ©1988-2010 ACORD CORPORATION.All rights reserved. ACORD25(2010/05) The ACORD name and logo are registered marks of ACORD �NCNr<N� NfN�A�IN Jk N NWdcuN N l Nin'NNS�IIN �N�ANN(If('R UNITED SOLAR A S S O C I A T E S , L L C May 29, 2015 Phung Ngo United Solar Associates 452 Pleasant Street Second Floor Malden, MA 02148 Town of North Andover Building Department 1600 Osgood Street Building 20, Suite 2035 North Andover,MA 01845 Dear Inspector: Please accept the enclosed permit applications for a residential solar system installation at 150 Liberty Street.It is greatly appreciated if the permits could be mailed to us once being reviewed and approved. A self-addressed envelope with stamp is enclosed for your convenience. Thank you for your cooperation.If you have any questions or if anything else is needed from us,please do not hesitate to contact me at 978-394-8231 or Jon Millburg at 781-264-4762. Sincerely, P Ngo Project Assistant United Solar Associates