Loading...
HomeMy WebLinkAboutBuilding Permit # 6/11/2015 TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO:( Date Received Date Issued: IMPORTANT: Applicant must cam Tete all items on this page I LOCATION 20AbbottStreet m Print. PROPERTY OWNER Derek Lax son Print 100 Yea��Old Structure es n yes (no MAP NO: PARCEL: ZONING DISTRICT: Historic District es Machine Shop Village yes TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building @ One family ❑Addition ❑Two or more family iJ Industrial @ Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑ Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer DESCRIPTION OF WORK TO BE PERFORMED: Installation of a 6.76 kw (26 panels)rooftop solar Installation of sistering OR lcrree wall Identification Please Type or Print Clearly) OWNER: Name: Derek Larson Phone: 213-286-.8236 Address: ata Abbott Street CONTRACTOR Name: Romain Strecker Phone 781-46 2-8702 /address: 10 Churchill Place,Lyrin M 0190 Supervisor's Construction License: 096385Exp. Date: 10/8/2016 tr Home Improvement License: 169698 Exp. Date: 7/27/2015 ARCHITECT/ENGINEER Richard Gordon Phone: Address: PO 63ox 264 Farr;ywille VA 23901. Reg. No. 49993 FEE SCHEDULE.BOLDING PERMIT.•$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ 261,653 FEE: $ � -_-- a Chet � k No.: Receipt No.: NOTE: Persons contracting with unregistered contractors do not have access to t/�e uara"tv,fund Signature of Agent/Owner see.attached aut�n form Signature of contractor °°� tkORTH -11adover Town of 4 � ® W.. to j No. ® Z, - jl ver' Mass, 1\ 1 �� COC NIC NI'WI[K -� AERATED A"I?\ �45 �S U BOARD OF HEALTH ERMIT T Food/Kitchen Septic System •. ..•• .• ••• ••.•. •• • BUILDING INSPECTOR THIS CERTIFIES THAT ............... Foundation ............................. has permission to erect.......................... buildings on . .. Rough to be occupied as . ...... ...................... ......... ............................................................ 01 Chimney Final provided that the person accepting this permit shall in eve respect conform to the terms of the application and on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, PLUMBING INSPECTOR Construction of Buildings in the Town of North Andover. Rough VIOLATION of the Zoning or Building Regulations voids this Permit. Final ELECTRICAL INSPECTOR PERMIT I I S Rough UNLESSCTI T . Service ..... . ............................... Final BUILDING INSPECTOR GAS INSPECTOR occupancy Permit Required t® Occupy Building, Rough Final Display in a Conspicuous Place on the Premises — Do Not Remove FIRE DEPARTMENT No Lathing or Dry Wall To Be Done Burner Until Inspected and Approved y the Building Inspector. Street No. Smoke Det. Optimize Engineering Co., LLC P.O.Box 264oFarmvillsoVA 23901 Ph:434.574.6138*E-mail: grichardpe@aol.com Richard B.Gordon, P.E. President January 5,2015 North Andover Building Department North Andover,MA Re: Solar Electric Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer In the State of Massachusetts. Please note the following conclusions regarding framing structure,roof loading,and photovoltaic system size and proposed site location of installation: i. Existina roof framing: Conventional framing 2x10 at 16"o.c.and 16'span(horizontal rafter projection).This existing framing structure below the residence roof is definitely capable for this photovoltaic project after sister the rafters with a 2x8 using(2)10d nails 21 o.c. Use of(2)Guard Dog Tm FMGD002 screws Is approved,or equal shear strength of approx.120 lb,2'o.c.at areas where little space is available only with remainder of member secured with(2)10d nails 21 o.c. If do not sister,then Install a 2x4 @ 16"o.c.knee wall over an Interior bearing wall to limit span of rafters between supports to 141-8". 2. Roof Loadina 0 4.33 psf dead load(modules plus all mounting hardware) 0 38.5 psf snow live load(55 psf ground snow live load reference) a 4.5 psf roof materials(shingles and sheathing) 0 Exposure Category 8,115 mph wind uplift live load of 19.6 psf(w Ind resistance) 3. Address of aroposed installation: Residence of Derek Larson,20 Abbott Street,North Andover,MA This Installation design will be in general conformance to the manufacturer's specifications,and is In compliance with all applicable laws,codes,and ordinances,and specifically,International Residential Code/ IRC 2009,2011 NEC,and 2012 ICC Energy Code. . The spacing and fastening of the Unfrac mounting brackets Is to have a maximum of 64"o.c.span along the rail between mounting brackets and secured using 5116"x 3%"length lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min.2" penetration of lag bolt per bracket,which is adequate to resist all 115 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters between rail rows for better distribution of roof load.Double quantity of anchors for modules mounted within 18"of ridge and edges of roof.Rails may be attached to either of two mounting holes in the L-feet.Mounting In the lower hole for a low profile,more aesthetically pleasing Installation or mount in the upper hole for a higher profile to maximize airflow under the modules to cool them more.Slide the 3,8-inch mounting bolts Into the footing bolt slots.The rails will be attached to the footings with the flange nuts. Very truly yours -A,4 I I e ine ring C F 41,,71 Ric orJnL ,P.E. i L Mass Vetts E. License No.49993 4 CIVIL ENGINEERING e!keCTF?IC4L ENGINEERING INSTALLATION OF NEW ROOF MOUNTED ABBOT STEETS 6.76kW PV SYSTEM 20 ABBOTT STREET NORTH ANDOVER, MA 01845 S \ Issued/Revisions 1 SITE VICINITY MAP NO. DESCRIPTION3dFDATE SCALE:NTS I Project Tide: ie: FTRIITY Project Address: 20 ABBOTT STREET NORTH ANDOVER,MA 01845 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX PV-1 COVER SHEET W/SITE INFO&NOTES Drawin Mile: JUNCTION BOX 1,THE INSTALLATION CONTRACTOR IS S THE DC VOLTAGE FROM THE PANELS IS 16, el CURRENT PREVAILING UTBl" / RESPONSIBLE FOR MSTALUNG ALL ALWAYS PRESENT AT THE DC COMPANYSPECIFICATIONS, kVA K LO-VOLT AMTHOUSAND CIRCULAR MBS PV-2 ROOF PLAN W/MODULE LOCATIONS PROPOSED 6.76kW EOUIPMEM ANO FOLLOWING ALL DISCONNECT ENCLOSURE AND THE OC STANDARDS,AND REQUIREMENTS kW KILO-WATT PERE DIRECTIONS AND INSTRUCTIONS TERMINALSOFTHEINVERTEROURING /6 THIS SET OF PIANS HAVE BEEN kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM SOLAR SYSTEM CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF L UNE INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL ANDAGENCYREVIEWAND MCB MAIN CIRCUIT BREAKER I Dravvinq Information 2 THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM AREWARNED APPROVAL.THIS SET OF PLANS SHALL MDP MAIN DISTRIBUTION PANEL RESPONSIBLE FOR INSTALUNGALL THATTHE SOLAR MODULES ARE NOT BE UTILIZED AS CONSTRUCTION MLO MAIN LUG ONLY DRAWING GATE: bfJ/2036 EOUIPMENTANDFOLLOWINGALL ENERGIZEDWHENEVERTHEYARE DRAWINGS UNTILREVISEDTOINDICATE MTD MOUNTED DRAWN BY: JC OIRECTTONS AND INSTRUCTION CONTAINED OW SEDTOLIGHT. 'ISSUED FOR CONSTRUCTIOW. MTG MOUNTING REVISED BY: INCOMPLETE MANUAL 9. LL APORTIONS OF THIS SOLAR 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL 3.THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE RESPONSIBLE FOR READING AND MAR KED CLEARLY IN ACCORDANCE WITH CONSTRUCTIONACTIVITIES. T NIC NOT IN CONTRACT stem lntortnatlon: UNDERSTANDING ALL DRAWINGS. THE NATIONAL ELECTRIC CODE ARTICLE NOd NUMBER COMPONENT AND INVERTER MANUALS 690. ABBREVIATIONS NTS NOT TO SCALE TOTAL SYSTEM SDf: 6.7 kW PRIOR TO INSTALLATION.THE INSTALLATION 10. PR IORTOTHEINSTALLATIONOFTHIS OCP OVER CURRENT PROTECTION TOTAL MODULE COUNT: 26 CONTRACTOR IS ALSO REOLIIREO TO HAVE PHOTOVOLTAIC SYSTEM,THE AMP AMPERE P POLE MOOULFSUSED: TRINA260 ALL COMPONENT SWTTCHESIN THE OFF INSTALLATION CONTRACTOR SHALL AC ALTERNATING CURRENT PB PULL.BOX POSITIONANOFUSES REMOVEDPRIORTO ATTEND A PRE414STALLTION MEETING AL ALUMINUM PH0 PHASE MODULF SPEC R: TSM-260P006.09 THE INSTALLATION OF ALL FUSES BEARING FOR THE REVIEW OF THE INSTALLATION AP AMP FRAME PVC POLY-VINYL CHLORIDE CONDUIT UTI UTf COMPANY: NATLGRIO SYSTEM COMPONENTS PROCEDURES,SCHEDULES,SAFETY AND App ABOVERNISHEDFLOOR PWR POWER UTIIRYACCT R: d03000031 0.ONCE THE PHOTOVOLTAIC MODULES ARECOORDINATION. APO ABOVE FINISHED GRADE QTY QUANTITY MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AW O AMERICAN WIRE GAUGE RGS RIGID GALVANIZED STEEL UTRTYMETER R: Id090438 CONTRACT OR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL C CONDUIT(GENERIC TERM OF SN SOLID NEUTRAL DEALTYPE: ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INTITAL RACEWAY,PROVIDEAS JSWBDSWrrCHB0PRO SOLAR PHOTOVOLTAIC INSTALLATION HARDWARECHECKSANDDCWIRING SPECIFIED) TYP TYPICAL COURSE ON SITE CONDUCTIVITY CHECKS CS COMBINERBOX U.0 1. UNLESS OTHERWISE INDICATED S. FOR SAFETY,IT IS RECOMMENDED BY THE 12 FOR THE PROPER MAINTENANCE AND CKT CIRCUIT WP WEATHERPROOF MANUFACTURE THAT THE INSTALLATION ISOLATLQN OF THE INVERTS REFERTO CT CURRENTTRANSFORMER XFMR TRANSFORMER Re V.No. Sheet CREW ALWAYS HAVE A MINIMUM OF TWO THE ISOLATION PROCEDURES IN THE CU COPPER DTZ MOUNT 72 INCHES TO BOTTOM PERSONS WORKING TOGETHER AND THAT OPERATION MANUAL DC DIRECT CURRENT OF ABOVE FINISHEDFLOOROR EACH OF THE INSTALLATION CREW 13. THE LOCATION OF PROPOSED ELECTRIC DISC DISCONNECTSWTCH GRADE MEMBERS BE TRAINED IN FIRST AID AND AND TELEPHONE UTILITIES ARE SUBJECT DWG DRAWING CPR, TO FINAL APPROVAL OFTHE EC ELECTRLCALSYSTEMINSTALLER UTILITY B.THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO APPROPRIATE COMPANIES AND EMT ELECTRICAL METALLIC TUBING BE INSTALLED FOLLOWING THE OWNERS. FS FUSIBLESWTCH CONVENTIONS OF THE NATIONAL ELECTRIC 16. ALL MATERIALS.WORKMANSHIP AND FU FUSE CODE ANYLOCALCODEWHICH MAY CONSTRUCTION FOR THE SITE ONG GROUND \�\O SUPERSEDETHE COMPONENALI.O B ERN. BE IN A CORDAMENTS CE WIT HEREIN SHALL HZ FREQUENCUND Y (CYCLES INTERRUPTER ..Jia ® 7.ALL SYSTEM COMPONENTS SHALLGOVERN.BE BE IN ACCORDANCE WITH: G FREQUENCY(CYCLES PER INSTALLED WITH THIS SYSTEM ARE TO BE N CURRENTPREVAILNGMUNICIPAL SECOND! 'UVUSTED.ALLEDUWMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS GENERAL NOTES O LA IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN W.PLEASE BE ADVISED THAT FINAL EQUIPMENT ANDIOR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVABABLTY OF EQUIPMENT. 3211MImwod Road BTI-J9]-24'�e ,WIN_I_,y D7]19 www.Trinlry-Solar.rom S•-3- NEW PV SOLAR MODULE.TYPICAL UNIRAC CLAMP U.O.I. CREFERTO EQUIPMENT SCHEDULE (—MSHEET MR MR FOR SPECS AND QUANRIIES) NEW MOUNTING FOOD ATTACHMENT SOLAR MODULE SOLAR MODULE POINTS,TYPICAL CRE RTO ENGINEERING LETTER FOR SPACING UNIRAC SOLAR MOUNT BEAM -'- AND DETAILS] X ODE9lE.. ET FOR 0ETP0.A 1 � 'F NEW UNIRAC RAiI.,TVPIGAL Q UNIRAC'L'FOOT ONE LAYER ASPHALT SHINGLES (REFER TO THE UNIRAC z(WESPEC SHEETPOrzpEI'al� 49EE ENaNeI:RstErrER FaR ePEO9I `�' � C006COMPWNT INSTALLATION SUNMODO FLASHING MANUAL FORSPECSAND DETARST Ogee spec SHE9i MR.ETA99 APOC SEALANT 1 a ISEESPEC EET PoROETARa NEW END CLIP.TYPICAL (REFERTOTHEUNIRAC iN MANUEAAL31SFOR SPECS ANDON m vR'T SOLAR MODULES SHALL NOT DETaLS) FEASTING RAFTER EXCEED PEAK HEIGHT. >tl1 I NEW MID CLIP,TYPICAL tREFERTp ENaNEER9lETTER PoR 3PECIFlUTI C REFER TO THE UNIRAC CODECOMPUANT INSTAL ATTACHMENT 6 CLIP DETAIL DMANUAL'2.5 FOR SPECS AND ETAILS) PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF sLALE:NOTTO SCALE SGALE:NDTTOSCALE sCALE'NOT TO SCALE NOTE:REFER TO MODULE SPECS FOR ACTUAL MODULE DIMENSIONS (SSUBd/ReVISiOns FRONT NO. DESCRIPTION DATE Project Title: DC LARSON,DEREK M FUD['P AC TRINITYACCT#:2014.44797 EP Project Address: 20 ABBOTT STREET NORTH ANDOVER,MA 01845 Drewin9 Tltle: R2 R1 PROPOSED 6.7 kW ' al -1 ._—I F SOLAR SYSTEM ' (r J t Dmwing Information DRAWING DATE: 6R/2015 o9Avm ar: tc REVISED BY: _ h _^ System Information: TOTAt5Y5TEM SRE: 6.7 kW TOTAL MODULE COUNT: 26 MODULESUSED: TRINA260 MODUIE5PEC8: TSM-260 PDO5.08 BACK UnInY COMPANY: NATLGRID UTILNYACCT#: 4010 W011 UTILITY METER R: 14090418 DEALTYPE: NOTES: 1.1 ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERSINSTALLATIONINSTRUCTIONS. RSV.NO. Sheet 2,1ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT Wmi MINIMUM NEMA 3R RATING. 3.1 ALL LOCATIONS ARE APPROMATEAND REQUIRE FIELD V RQATION. 4 t LOCATIONS SOLAR INSTALLATION ONLY Y PV ARRAY"LL NOT Efi`?:;•NO BEYOND ,E EXT;=,TNG BUILDING EN-'ELOPE v PLUMBING SCHEDULE EQUIPMENITSCHEDULE ARRAY SCHEDULE SYMBOLLEGEND NEW END CUP,TYPICAL(REFER TO THE UNIRAC OTY SPEC INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UTILITY DISCONNECT TO BE CODE-COMPUANT INSTALLATION MANUAL TRINA 260(TSM-260 PDOSM) ARMYORIENTATION=159.4' ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE ® SECTION 325 FOR SPECS AND DETAILS) 26 \\\\\ MODULE PITCH=35' DICATESNEWPVSOLARMODULC 1 SE6000A-US \� INRc�O MODULES NEW MIO CLIP,TYPICAL(REFER TO THE UNIRAC �\ INDICATES E%16TIN0 METER LOCATION I„t INDICATE PANELS THAT USE MICRO INVERTERS. ® CODE-COMPLIANT INSTALLATION MANUAL ARRAYOMENTATON=154.6' REFER TO EQUIPMENT SCHEDULE FOR SPECS. SECTION 3.2S FOR SPECS AND DETAILS OTHER OBSTRUCTIONS MODULE PITCH.35' EP LOCATION:IN BASEMENT I I INSTALLED OURIDE. __ (REFER O THE UNTYPICAL S 0 1 A R INDICATES EXISTING ELECTRK:AL PANEL INDICATES NEW PRODUCTION METER TO BE . (REFERTAC RAIL IRAC CODE COMPl1ANT J f'�n INSTALLATION MANUAL FOR SPECS AND DETAILS) a NECT T09E INDICATES NEW INVERTERTO BE NEW MOUNTING FOOD ATTACHMENT POINTS. INDICATES NEW MAIN DISCON221t Nlemwod Rwd 8T/-79]-2978 p INSTALLED E, TYPICAL(REFER TO ENGINEERING LETTER FOR W4ILN 1-70TH9 www.Trinlry,5olar.com GROUPED WITH MNN PANEL REFER TO EQUIPMENTSREDULE FOR SPECS. SPACING ANO DETAILS) Engineer I License Holder. Charles P Bonicker Trinity Heating&Air, Ino DBA Trinlry Solar a'--"'�'--'- 2211 Allenwood Rd.Wall,NJ 07719 MOUNTED UNDER SOLAR MODULE ------SOLAR MOOULESMOUNTEDTO ROOFON 2 ARRAYS NEC 690,34 J 26-260W MODULES W/1 SOLAR EDGE P300 PER MODULE ---- 18.75 ADC MAX PER STRING 2 STRINGSOF I3MODULESINSERIES-3WVm- --- -- _ JUNCTION - JUNCTION - - F •2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER - BOX BOX t i Issued 7 Revisions C I NO. �LeDESCRIPTION a DATE i Project Title: 1 CARSON,DEREK 3 TRIWTI'AIIM201444797 ARRAY CIRCUIT WIRING NOTES s Project Address: COMPLIES WITH 2011 NEC CFCI RECEPTACLE 1p15A BREAKER i.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON EXISTING '240V—� 1p 2D ABBOTT 14/2 NM CABLE ASHRAE MINIMUM MEAN EXTREME DRY BULB /20I240V 1 ,M 200A MAIN BREAKER TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO UTILITY I NORTH ANDDEr OVVERER,MA 01845 INSTALLATION LOCATION, LOWEST EXPECTED AMBIENT METER 200A BUS@AR FjE.A TEMP=-36'C2.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED € Drawing Title! ON ASHRAE HIGHEST MONTH 2 DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO DISCONNECT FUSED i PROPOSED 6.76kW INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= - WJ 40A FUSES 60A UNFUSED SOLAR SYSTEM 33'C GROUPED W/MAIN PRODUCTION II BREAKER LOAD CENTER METER DISCONNECT D 3.)2005 ASHRAE FUNDAMENTALS 28 DESIGN i INVERTER 81 DraWin Info TEMPERATURES DO NOT EXCEED 47-C IN THE UNITED ? 240Y 10 _ 24DY 1. rmatlon STATES(PALM SPRINGS.CA IS 44.10. FOR LESS THAN I ooeooe aoeeoo _—__ +� D35 9 CURRENT-CARRYING CONDUCTORS IN A -- e ° 6 0 DRAWING DATE 6 DRAWN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5"ABOVE -- _ € REVISED DY. ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE f �n �` _ I 47-C OR LESS(ALL OF UNITED STATES), i 1 N b e p e R F nforma 4.)PHOTOVOLTAIC POWER SYSTEMS SHAH BE ^- '- a �r�mo�}L-- O - L+ reoeeeo� ` „ 000 006 ',.. 7 REV ' 0 System I tion: PERMITTED TO OPERATE WITH UNGROUNDED - e e +., _ i, i E TOTALSYSTEMS- 6.]6kW PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER SQUARED SQUARED j -�?'`------- TOTAL MODULE couNr: 16 NEC 690.35 EXISTING MAIN BREAKER LOAD ® PN: D222R8 _- ____-� MODULES USED: TRINA26D CENTER INSULATED LINE TAPS PN: D222N N1o0ULE5PEC4: TSMS60P005.08 5.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE INSTALLED ON MAIN FEEDERS A NEMA3 RATING. NEC 690.64 un 40ID MI UTILITY ACCSW: 401D00031 Ul"T'METER P: M090418 CAICULATIDN5 FOR CURRENT CARRYING DEALTYPE: CONDUCTORS REQUIRED CONDUCTOR A )1 PER SIRING 690.5(e)(1)k (15.00-1,25"i.25)i 18.75A AWG 010,DERATED AMPACITY PVMODULE SPECIFICATIONS AMBIENT TEMP:55C,TEMP DERATING FACTOR: .76 TRINA 26 W MM-260 PS.0R) ReV.NO. Sheet RACEWAY DERATING-4 CCC: 0.80 Imp a5 (40`.76)0.80-24.32A P 1 PV - 3 Vmp 30.6 24.32A'-18.75A.THEREFORE WIRE SIZE IS VALID Voc e A 46TNwTW/2-00EXL Z GROUND ROD TOTAL AC REQUIRED CONDUCTOR AMPACITY Tac 9 a 3/4"EMT W/2-NDTHWN-I,i-A10THW1L21-R10TH—GROUND 25.01OA"1.25-31.25A AWG{g8.DERATED AMPACITY C 3/4"EMT WJ4-p10 THWN-2,I-RDTHiWN-2 GROUND INVERTER 41-SE6OWA-US AMBIENT TEMP:30'C,TEMP DERATING:1.0 D 3/4"EMT W74RSDTNWN-2.1-pDTHWN-Z GROUND F RACEWAY DERATING`-3 CCC: N/A DC AC e 55A"1.0-55A Imp 18 pout 6000 E 3/4"EMT W(Z•UBTHWN•2.1-NIOTHWN-2,1.410TNWN-2 GROUND 55A'_3125A THEREFORE AC WIRE SIZE IS VALID vmp 350 lout 25 F A32PVVAREw/AD DAREcopvERDDNOTOMooULESANORMLS SOLAR Yoc 500 Imaz 31.25 3/4"TMCW/346TXWN�2.1-Nil -2 GROUND GLCUtA7ION FOR PV OYERCURRENT PROTECTION G TOTAL INVERTER CURRENT: 25.00A He 30 Vnpm 240 2211 AIIemwod Road 627-]9]-2978 25.00A•1.25-31.25A w.,n,N-"lenryOm9 www.Trmiry-xw.cem -->40A OVERCURRENT PROTECTION IS VALID MATERIAL LIST f , 0 JOB NAME: LARSON, DEREK ADDRESS: 20 ABBOTT STREET SOLAR NORTH ANDOVER, MA 01845 2211 Allenwood Road 877-797-2970 Wall,New Jersey 07719 www.Trinity-Solar.com DAYS 38.504 ESTIMATED MAN HOURS 1.6 6MEN)DAYS(3 1.2 DAYS(4 MEN) 0.8 MEN) (6 • 26 TRINA 260's(6.76KW) • 2 SEPARATE ARRAYS • 33' PEAK TO GROUND • 26 PORTRAIT&0 LANDSCAPED • NO PIPES OR VENTS BEINGS RELOCATED OR REMOVED • 1 INVERTERS INSTALLED OUTSIDE • NO TRENCH ESTIMATED SENT TO JOB USED ❑ TRINA 260(TSM-260 PD05.08)---P300 SE OPTIMIZERS 26 ❑ SE6000A-US 1 ❑ 60A INDOOR FUSED DISCONNECT W/(2)40A FUSES 1 _ ❑ METER AND METER PAN 1 ❑ 60A OUTDOOR NON-FUSED DISCONNECT 1 _ _ ❑ SOLADECK BOX(ES)&HAYCO CONNECTOR(S) 2 _ ❑ 14'SECTIONS OF RAIL 15 _ _ ❑ INSULATED BUG BITES(LINE TAPS) 2 ❑ FLASHINGS 52 _ _ ❑ CASE(S)OF BLACK SPRAY PAINT 1 _ ❑ CASE(S)OF TAR 1 _ _ ❑ TP LINK 1 ❑ PV LEAD WIRE 100' _ _ ❑ T-BOLTS _ _ — El MID CLIPS _ — — ❑ END CLIPS _ ❑ SPLICE KITS _ — — ❑ GROUND LUGS _ _ — INSTALLATION OF NEW ROOF MOUNTED ASSESTi STREET 0 6.76kW PV SYSTEM 20 ABBOTT STREET - S NORTH ANDOVER, MA 01845 Issued/ReVlSlonS VICINITY MAP N0. �mDESCRiPT10N MP DATE SITE SCALE:NTS Project MUD: LARSON'D I'll,DEREK TRINITY ACCT M 2DiaaaTST Project Address: 20 ABBOTT STREET NORTH ANDOVER,MA 01845 SHEET INDEX Drawn TIUe: GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONSJUNCTICONTINUED i.THE INSTALLATION CONTRACTOR IS B THE DC VOLTAGE FROM THE PANELS IS 14. B)CURRENTPREVAIUNGUTILITY JB THOUSAND CI PV-1 COVER SHEET W!SITE INFO&NOTES RCMIL TILOUVOL AM ERE MILS PV-2 ROOF PLAN W/MODULE LOCATIONS PROPOSED STE.W RESPONSIBLE 0FOLL FOLLOWING ALL ALWAYSDISCONNECT PREECT ENCLOSURE THE N STANOAYS AND kVA KILO-VOLTAMPERE SOLAR SYSTEM EQUIPMENT ANO INSTRUCTIONS NGALL TERMINALS OF THE INVERTER ANO THE OC STSET OF LAND REQUIREMENTS XVy KILO-WATT PV-3 ELECTRICAL 3 LINE DIAGRAM CONTAINED IN INSTRUCTIONS TEYLIGHT OURS.INVERTER DURING /6 THIS SETOFORTHE UR BEEN RWH KILOWATT HOUR CONTMATRON THE IVSD MOMPACKAGE AND DAYLIGHT ON HOURS.ALL PERSONS PREPARAL ANDA E AGENCY L UNE INFORMATION RECEIVED FROM TRINITY. WORKING ON ORINVOLVEDME NE MUNICIPAL ANDA GENCY REVIEW AND MCB MAIM CIRCUIT BREAKER DreWl IMormation 2.THE INSTALIATIDN CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL THIS SET OF PIANS SHALL MOP MAIN DISTRIBUTION PANEL IDIA"N.IATI 16/2/2DIS RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE NOT BE UTILIZED AS CONSTRUCTION MLO MAIM LUG ONLY pgAWN BY: lC EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE DRAWINGS UNTIL REVISED TO INDICATE MTD MOUNTED DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. -ISSUED FOR CONSTRUCTISHOWNON", MTG MOUNTING REVlSE08Y: IN THE COMPLETE MANUAL B. ALL PORTIONS OF THIS SOLAR 16 ALL INFORMATION TO USE BE N NEUTRAL 3.THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SWILL BE CERTIFIED PRIOR TO USE FOR NEC NATIONALELECTRICAL CODE RESPONSIBLEFORREAOINGAND MARKED CLEARLY IN ACCORDANCE WITH CONSTRUCTION ACTIVITIES. NIC NOT IN CONTRACT system lnfomudlon: UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRIC CODE ARTICLE NO NUMBER TOTAL6Y6TEM6�: &761,WCOMPONENT AND INVERTER MANUALS 690. ABBREVIATKINS NTS NOT TO SCALE TOTALMODULECOUNT: 26 PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS OCP OVER CURRENT PROTECTION CONTRACTOR IS ALSO REOUIRED TO HAVE PHOTOVOLTAIC SYSTEM.THE AMP AMPERE P POLE MODULES U6ED: iA1NA26D ALL COMPONENT SNITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL AC ALTERNATINGCURRENT Pe PULL BOX MODULE SPEC a: TSM-260 Pp06.0R POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRC4NSTALLTION MEETING AL ALUMINUM PHO PHASE UTILITY COMPANY: NATLGRID THE INSTALLATION OF ALL FUSES BEARING FOR THE REVIEW OF THE INSTALLATION AF AMP.FRAME PVCPOLYVINYL CHLORIDE CONDUIT SYSTEM COMPONENTS. PROCEDURES,SCHEDULES.SAFETY AND AFF ABOVE FINISHED FLOOR PWR POWER UnLffYAffi N: e0100D011 0.ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AFG ABOVEFMSHEDGRADE OTY QUANTITY UnIITY METERp: 34090418 MOUNTED.THE INSTALLATION it. PRIOR TO THE SYSTEM START UP THE AWO AMERICAN WIRE GAUGE FIGS RIGID GALVANIZED STEEL DEAL TYPE: CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL C CONDUIT(GENERICTERMOF SN SOLIDNEUTRAL ONE ELECTRICIAN WHO HAS ATTENDEO A ASSIST IN PERFORMING ALL INITIAL RACEWAY,PROVIDE AS JSWeDSWRCHBOARD SOLAR PHOTOVOLTAIC INSTALLATION HARDWARECHECKSANDOCWIRING SPECIFIED) TYP TYPICAL COURSE ON SITE CONDUCTIVITY CHECKS CB COMBINER BOX U.0 1, UNLESS OTHERWISE INDICATED B.FOR SAFETY.IT IS RECOMMENDED BY THE 12 ISO E PROP ER MAINTENANCE AND CKT CIRCUIT WP WEATHERPROOF R. ND. Sheet MANUFACTURETHATTHE INSTALLATION ISOLATION OF THE INVERTS REFERTO CT CURRENTTRANSFORMER XFMR TRANSFORMER CREW ALWAYS HAVE A MINIMUM OF TWO THE ISOLATION PROCEDURES IN THE CU COPPER 172 MOUNT 72 INCHES TO BOTTOM PERSONS WORKING TOGETHER AND THAT OPERATION MANUAL DC OtRECT CURRENT OFABOVEFNISHEDFLOOROR PROPOSED ELECTWC EACH OF THE INSTALLATION CREW 13. THE LOCATION OF DISC DISCONNECT SWITCH GRADE v MEMBERS BE TRAINED IN FIRST AID AND AND ELHO TELEPHONE UTILITIES SUBJECT ONG DRAWING CPR EC ELECTRICAL SYSTEM INSTALLER 8.THISSOLAR PHOTOVOLTAIC SYSTEM ISTO APPROPRIATE Un LRY COMPANIES AND EMT ELECTRICAL METALLIC TUBING BE INSTALLED FOLLOWING THE OWNERS. FS FUSIBLE SWITCH CONVENTIONS OF THE NATIONAL ELECTRIC 14. ALL MATERIALS,WORKMANSHIP AND FU FUSE S \i\� • CODE.ANY LOCAL CODE WHICH MAY CONSTRUCTION FOR THE SITE GND GROUND SUPERSEDE THE NEC$HALLGDYBRN. IMPROVEMENTSSHOWNHEREINSHALL OR GROUND FAULT INTERRUPTER T.ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH' HZ FREQUENCY(CYCLES PER INSTALLEDWITMTHISSYSTEMARETOBE Al CURRENT PREVAILING MUNICIPAL SECOND) -UL'LISTED.ALL EQUIPMENT WILL BE NEMA ANWOR COUNTY SPECIFICATIONS, 3R OUTDOOR RATED UNLESS INDOORS, STANDARDS AND REQUIREMENTS O 1L Q� GENERAL NOTES 2211 Aiemvoad Road 877-797-2978 IFISSUEDDRAWINGISMARKEDWITHAREVISIONCHARACTEROTHERTHAN-A'.PLEASEBEADVISEQTHATFINALEQUIPMEMANDIORSYBTEMCHARACTERISTICS ARESUBJECTTOCHANGEDUETOAVAILAB OFEQUIPMENT, Wall,Nnviersry OT/t9 www.Trinlry-Solar.�om UNIRAC CLAMP L SEE SPEC SHEET FOR DEfA- 3'-3' NEW PV SOUR MODULE.TYPICAL (REFER TO EQUIPMENT SCHEDULE U.O.I. Fpft SPECSAND UA ES) SOLAR MODULE �\ SOLAR MODULE \\.SS N NEW MOUNTING FOOTi ATTACHMENT UNIRAC SOLAR MOUNT BEAM POMTS TYPICAL (REFERTO (9EESPECSHEETFDROETA , _ ENGINEERING LETTER FGRSPACING _ U,_ AND DETAILST UNIRAC'L'FOOT ONE LAYER ASPHALT SHINGLES "' L(SEE SPECSHEETPCROETAA31 (SEEENWNEERS LEnERPOP SPECS _ __--_ NEW UNIRAC RAM1.TYPILAL SU�NMOIIO FLASHING APOC SEALANT iN� • iftEFER TOTHE UNIRAL E ECSHEET POROeTAtt9 CODE-COMPINNi MSTALLATION (SE tS0.`yEc EE*POROErML9 MANUAL FOR SPELS AND DETNLS7 // � S4\ NEW END CUP.TYPICAL s`""�auT SOLAR MODULES SHALL NOT f�i )L\ t REFERTOTHE UNIRAC EXCEED PEAK HEIGHT. LMN4UEA 0325 FOR SPECS ANON EXISTING RAFTER --_—_a—_ _ DETAIL: tREFERTOwdNEERSLETIER WR9vEdFlc^^TIOtd - NEW MID CUP.TYPICAL HEIGHT FROM GROUND LEVEL TO PEAK OF RO (REFERTOTNE UNIFiAC SCALE:NOTTOF O SCALE ISSUed/RBVISiOns LOOECOMPUANT MSiPUARON MANUAL325 FOR SPECS AND pV MODULE ATTACHMENT ON ASPHALT SHINGLE Roo' pETAILS) SCALE:NOT TO SCALE ATTACHME8 CLIP DETAIL _ SCALE:NOT TONT SCALE NOTE'AMAt-MODULE OIMENSIONSR __ wmou NO. �mDESCRIPTION Hn DATE FRONT Project Title: LARSON,DEREK DCTRINITYACCTW2ol4� 797 M UD P AC ProjeDt Address: EP 20 ABBOTT STREET NORTH ANDOVER,MA 01845 Dlawln9 TlIle: PROPOSED 636kW SOLAR SYSTEM Draw! InfOrmaflon L �y -� pRAWINDATE: IERR035 DRAwN BY: C �I REVISED BY: a I _ S stem Information: TOTALSYSTEC', 6.,W TOTAL MODULE COUNT: 26 MODULES USED: TRINA260 MODULESPEC M: TSM-26D P005.00 UTILITY COMPANY: NATLGRIO "ACCT M: 4010 Well BACK 14D9B41s umm mETER R: DEALTYPE: Rev.No. Sheet NOTES, Pi PV - 2 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WIHTHE MANUFACTURER'SIN`ENTSHALLBSTRUCTIONS. 27ALL OUTDOOREG UIPMENT SHALL BE RAINRGHT WITH MINIMUM NEMA3R RARNG PLUMBING SCHEDULE EQUIPMENT SCHEDUL 0.)ALL LOCATIONS ARE P.PPRO)WATEAND REQUIREFlELD VEPoFICATION. OTY SPEC 6� nOOFTOP SAAR INSTALLATION PEO IO•ZgY;v ARR;�?v4'LLL NC`f E,k.-.ND .YOEdO THE EXISTING`Cs LOk:C,`.'4'.O— NEW ENO CUP.TYPICAL(REFER TO TF IS UNIRAC UAL 26 TRINA260(TSM-20O PODS-08) I \\ • SYMBOLLEGEND ® CODELOMPLV.NT INStAt1ARONMAILS) ARRAY SCHEDULE INDICATES NEW LMUT'OISCONNECT TO 9E SECTION 325 FOR SPECS AND DETA149 1 5E6000A-VS Al 1 INDICATES ROOF DESIGNATION.REFERTO UD INSTALLED OUTSIDE ARRAY ORIENTATION ® ARRAY SCHEDULE FOR MORE INFORMATION MODULE PaN=3S CODECOMPLIANTISPECS AND DEANUAL O.I.HER OBSTRUCTIONS SOLAR INDICATES NEW PV SOLAR MODULE RE=MODULES ® NEW MID CLIP.TVP' THE UNIRAC INDICATE PANELS THAT USE MICROINVERTERS. C-0-0 N 325 FOR SPECS AND DETARS) RI INDICATES EJOSRNG METER LOCATION REFERTO EONPMENT SCHEDULE FORSPECS. NEW UNIRAG RAIL,TYPICAL eP T97 2920 ARRAY ORIENT ATION-159.4' M _ (REFER TO THEUNMACCODE.COMPUANT 2211 gI1emmod Road ,w,TrMI 51 MODUUPRCN=35' INDICATESNEWPRODUCTIONMETERTOBE INSTALtA.TION MANUAL FOR S— F— FECS AND DETAILSI Wa11.Nca ll^^vY 07)19 ry-oar cvm INDICATES E%ISTING ELECTRICAL PANEL '1+, INS.TAL;ED OUTSIDE. __ EP LOCATION:IN BASEMENT tll ••• NEW MOUNRNG FOOTI ATTACNMEM POINTS. INOICATESNEWINVERTERTOBE TYPICAL(REFER TO ENGINEERING LETTER FOR D Q ® ST ROUPINALLED OU151OE. SPACMG AND DETAILSI IESNEW MAIN DISCONNECT TO BE A GROUPED WITH MAIN PANEL REFERTD EQUIPMENT SCHEDULE FOR SPECS. E ngineerse Holder, onicker ng&Air, ity Solar ---_, .Wall,NJ 07719 �— MOUNTED SOtARMOOULESMOUNTEDTOR00FON'ARRAY' UNDER SOLAR MODULE 26-26UW MODULES W)S SOLAR EDGE P300 PER MODULE NEC 690.34 -_- 3g.7SA-I%AX PER SIRING '- -- JUNCTION C --JUNCTION - - 2 STRINGS OF I3 MODULES IN SERIES-350V— _ -- - F eox Box . `251RINGSTO SE TERMINATED IN PAMLLELINSIDE INVERTER I IssDed/ReVISK"a f i 1 I '. I syzou NO. eN DESCRIPTIONnN DATE I Protect Title: CARSON,DEREK 't TRINITY ACCTM 2014-44797 1 ARRAY CIRCUIT WIRING NOTES Project Address: I CFCI RECEPTACLE COMPLIES WITH 2031 NEC 1p15A BREAKER 1J LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON EXISTING 240V 1m 14/2 NM CABLE 1 20 ABBOTT STREET ASHRAE MINIMUM MEAN EXTREME DRY BULB 120/240V 200A MAIN BREAKER NORTH ANDOVER,MA 01845 TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO UTILITY DDA-SEAR r INSTALLATION LOCATION. LOWEST EXPECTED AMBIENTMETER iTEMP--JVC Drawln9 Title: 2.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ! ON ASHRAE HIGHEST MONTH OC DRY BULB 60A DISCONNECT FUSED I PROPOSED STEM TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO WJ 40A FUSES INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP- 60A UNFUSED SOLAR SYSTEM 33'C tl GROUPED WJ MAIN PRODUCTION DISCONNECT BREAKER LOAD CENTER METER INVERTER#1 DrawD 3.j 2005 ASHRAE FUNDAMENTALS 2C DESIGN 240V lm 40V im TE. TEMPERATURES DO NOT EXCEED 47'C IN THE UNTIED , ..... . Infonna OI 6STATES(PALMSPRINGS,CAIS44.'C). FOR LESS THAN 11 1°° jc9CURRENT-CARRYING CONDUCTORS INA ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5 ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE >--- OF 47-C OR LESS(ALL OF UNITED STATES), e 1 ® p = E 1 0 a I 0 D - - - G j '1- B - - - --r t 000 00 STA e5Y5iE formatio 6.7 W 4.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE --- eeeeee I ' n: PERMITTED TO OPERATE OATH UNGROUNDED L-___-- - --' r-` i TOTAL MODULE coum: z66k PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER /. SO ARE D SQUARE D = -``�-----' NEC 690.35 EXISTING MAIN BREAKER LOAD ® PN: 0222RB ----� MODULES USED: TNNA 260 CENTER INSULATED LINE TAPS VPN: D222N MOoutE SPEC R: TSM-26o PO05.oe 5.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE INSTALLED ON MAIN FEEDERS unlnY COMPANY: NATLGND A HEM 3 RATING, NEC 690.64 UTILITY MET R: 403000013 UTLITY METER R: 1404W18 CALCULATIONS FOR CURRENT CARRYING DEALTYPE: CO REQUIRED RS REQUIRED CONDUCTOR AMPACITY PER STRING (15.00'1.25)1-18.75A AWG q10.DERATED AMPACITY PV MODULE SPECIFlCATIONS RBV.NO. SM1eOt AMBIENT TEMP: 55'C,TEMP DERATING FACTOR: .76 TRINA260(ISM-2WPWS.Og) RACEWAY DERATING=4 CCC: 0.80 Imp 95 P 1 ��j (40.76)0.80-24.32A V.P 30.6 JI/A" GWGRGUNo NGGR0U-POP 1. 24.32A'-18.75A,THEREFORE WRE SIZE IS VALID VOC 38.2 W/ 2,1-XiOTHWN-3.S�MIOTHWN3 GROUND TOTAL AC REQUIRED CONDUCTOR AMPACITY m 9 25.00A•1.25-31.25A W1 -2.348THWN3 GROUND \... • AWC pe,DERATED AMPACITY INVERTER ml-SE6000MUS W/ 2.3-gBTHWN-'GROUND AMBIENT TEMP. 30'C,TEMP DERATING: 1.0 AC RACEWAY DERATING=3 CCC: N/A DC W7z,l-alo7xwN-3,Sx10 TRwN-268DUNp 55A'1.0-55A ImR is Pout 60W 55A--31.25A THEREFORE AC WIRE SIZE IS VALID Vmp 350 Tout 25 IRECOPPERRONDTOMODULESANDRNI6SOLARW/ -'.3-ae TNWN-2 GROUND CALCULATION FOR PY OVERNRRENT PROTECTION Rc VRom 240 2211 Allcmv Road g77-797-2979 TOTAL INVERTER CURRENT:25.00A Wa14 Newlersey 07719 www.Trinlry-SOIucOm 25.00A-1.25-31.25A -->40A OVERCURRENT PROTECTION IS VALID MATERIAL LIST JOB NAME: LARSON, DEREK 4 ADDRESS: 20 ABBOTT STREET SOLAR NORTH ANDOVER, MA 01845 2211 Allenwood Road 877-797-2978 Wall,New Jersey 07719 wwwSriniry-Solacmm 38.504 ESTIMATED MAN HOURS 1.6 DAYS(3 1.2 DAYS(4 MEN) 0.8 8MEN) (6 MEN) • 26 TRINA 260's(6.76KW) • 2 SEPARATE ARRAYS • 33' PEAKTOGROUND • 26 PORTRAIT&0 LANDSCAPED • NO PIPES OR VENTS BEINGS RELOCATED OR REMOVED • 1 INVERTERS INSTALLED OUTSIDE • NO TRENCH ESTIMATED SENT TO JOB USED ❑ TRINA 260(TSM-260 PD05.08)---P300 SE OPTIMIZERS 26 — — ❑ SE6000A-US 1 — — ❑ 60A INDOOR FUSED DISCONNECT W/(2)40A FUSES 1 — — ❑ METER AND METER PAN 1 — — ❑ 60A OUTDOOR NON-FUSED DISCONNECT 1 — — ❑ SOLADECK BOX(ES)&HAYCO CONNECTOR(S) 2 _ — ❑ 14'SECTIONS OF RAIL 15 — — ❑ INSULATED BUG BITES(LINE TAPS) 2 — — ❑ FLASHINGS 52 — — ❑ CASE(S)OF BLACK SPRAY PAINT 1 _ — ❑ CASE(S)OF TAR 1 — — ❑ TP LINK 1 — — ❑ PV LEAD WIRE 100' — — ❑ T-BOLTS — — — ❑ MID CLIPS — — — ❑ END CLIPS — — — ❑ SPLICE KITS — — — ❑ GROUND LUGS — — — s0I a r=gq Single Phase Inverters for North America S®lSE3000A-USI SE380OA-US I SE5000A-US I SE6000A-USar ( L7 SE760OA-US/SE1000OA-US if SE1140OA-US SF3000A-US SE380OA-US''..SESDDDA-US'SE6000A-US SE760OA-US SE100(i US SE11400A-US +� OUTPUT SolarEdge Single Phase Inverters Nominal AC Power Output 3000 3900 5000 6000 7600 9980 @`48V 11400 VA 10000 0V For North America @20V 10800@240V Max.ACF Output ^x00 also 5400 60o0 8350 12000 VA 54so @24ov 10950 @24ov AC Output V ltage Min.-Nom Max.� J SE300OA-US(SE380OA-US(SE500OA-US J SE600OA-US l 1 C3 v AOutput Voltage Min:Nam Max' ✓ ✓ J ! ✓ ✓ '.. J 211-_40 '.. SE760OA-US/SE1000OA-US I SE1140OA-US . AC Frequency MiMrn:Nam:Max" 59.3-60 605{wiCh.H)c-unYN zeMng S]-60 60.5) ....,..,.... - - ,._ - - Max. u ax.C-nrious Cutput Current 12.5 -- 16 -24@20SV 3 -48 @ 208V_ 21 25 "2 11.1 A \' 42 1�240V GFDI 1 __ _ A ' \ �� Utll ty M- t r g cid'gP t ttton Country Configu2ble Thresholds YES Yes K, Recommended M DC P-wer INPUT 3750 4]50 6250 7500 9500 12400 14,50 W 14 fNrm foU g ounded es y �($ 1-1-160 M Input voltage 500 Vdc _ Nam Ci R CV It g 325@20 V/350@240V — Vtic ' NIN INK ���\� ax.Input 9.5 13 13 ' 4'5 A 155@203V 3'<@^_00V MI - pu _ 155@240V_..._ _305@"�2doV_. Max.Input Short Circuit Current 45 Ado krrlR erse-R Ity Protection Y p- Ground-Fault sri Detection ns MI Maximum rt Ef 1 M 977 _ 3 9--3 - ° _ 9 _ 98 ss 97.5 @ 208V 97 @1 208V CEC Weighted EFfl Y.. 97.5 ... 8 n8 @ 240V .. 97.5 97.5 .47 5 @ 7 5 %..... - 34ov NIEhM eF C pn n s 4 W ADDITIONAL.FEATURES _ a��aO — _ Ethernet, Bee nonall _ Supported Commuri canon Interface.; RS485,RSZ'<,Eth g i-p_ .. \ Rc­ue Grace Data..ANSI C121 .. ...Opb I _.. ... Rapid Shutdown-NEC 201469012 F.Pot aliry enabled when 5o1,rEdge rapid shutdown ,us in lled" STANDARD COMPLIANCE Safety UL3741,UL16998 UL1 98,CSA 222 _.. ... _. � Grid C vection Standards IEEE1547 _ Enhavoin, FCC p rt15 class 6 ' INSTALLATION SPECIFICATIONS AC output cand,it size/AWG range 3/4m/16-6AWG _ (4 min )E'AW_G R DC input2' d t size19 ofstrings/ 3/4 minimum .. m um/12strg/16-6 AWG 3/4 um/12 string-, AWG AWG range Drmen-rq,.with safely Switch ._. - _- - J --- - -- -- Aawc 30.5x I_.5 x 7/ 305 12'5x75 305 x 12.5 x 10.5/775 x 315,260 in/ -. ^I CHxWgq) 775 x 315_x 172 - 775 x 315 r,191 mm Wight with Safety Switch400 1 51: 2.3.2 547124.7 834J401 lb/kg u me laceable CoollnE-, Natural Convection Far,( P ) Nese -. _. ... <`s. _... _. <So dBA M Max.Operating Temperatum 13W 140(25 to-60(-00 to+W version avalable') `F/'C The best choice for SolarEdge enabled systems Range Protect-,Racing _ NEMA3R ev Integrated arcfault:protection(Type 1)for NEC 2011590.15 compliance -Superior efficiency(99%) -Small,lightweight and easy to install on provided bracket -Built-in module-level monitoring :-/maeanisc->t nlu;se�.n.r.rwcaarvx — Internet connection through Ethernet or Wireless s Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue:grade data,ANSI C12.1 USA GERMA .-x_='-FRANCE 1APAN F'f,'�,-, 1 .,_i., -11,ME F LAN .SP.zu www.soiaredge.us �J, o l a r, � SolarEdge Power Optimizer S��11 V' r Module Add-On for North America P300 1 P400 I P405 SolarEdge Power Optimizer P3°° P40D P405 ifor 60-tail modules) (for 72&9Fm17 modules) (foe thm film module) INPUT _.. Module Add-On For North America Rated Input DC Power" _ 300 400 405 W_ _ _ - Absolute Maximum input Voltage 48 80 125 Vdc l��} ppfft�(� ( Me at lowest temperature) - -- 8 80 _ 12.5-105 Vol �41U CYtfV 1P405 Me Opiann6Range .. ... .. 8 48 - .. 70 Adc M ximum short Circuit Current(Isc) _.. _. -. — ,�.,,.. 12.5 _. .._. _.._. Adc Maximum DC Input Current _ gg 5 �w — Weighted Efficiency 988 vOvervolta e Category OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERT»_ �� Maximum Output Current _ _.. 15 85 A c \ Vdc \ Max mum Output Vol[age 60 �, OUTPUT DURING STANDBY(POWER OPTIM2ER DISCONNECTED FROM INVERTER OR INVERTER OFF) vdc 1 \, safaty Output Voltage Per Power Optimizer � STANDARD COMPLIANCE FCC Part15 Class B.IEC61000-6-2,IEC61000-6-3 y.�.." _ _.. EMC _. _- - ss II -'- IECF21091(class safety),11L174Y . t.: Safety Yes fi RoHS fjY INSTALLATION SPECIFICATIONS Vd_c Maximum Alowed System Vo it g 1412212 x405/5 SS z834x 1.59 mm/in m "W"', � Pxii2series... -.-.- 128 152 3S/ 128 152x48/ �� \ 'O Dimensions{Wxlx H) 128x152.27.5/ mm/in �. Pxxx 5series S x 5 97 x 1.08 5.5.97111.37 _ 5.5.97.1.89 _. 9so/z.1 gr/lb Pxx 2 n s _. 930/2.05 gr/lb Weight(including cables) Pxxx 5 series _ 770/1 7 930/2-05 _. - - input Connector _ MC4C p able ... - - Double Insulated;Amphenol _ output Wire Type/Connector 12/39 m/ft output Wire Length _095/30 - C/:F ' Operating Temperature Range IP6S-40 /-40-+i85_ - Pxxx-2 series IP65(NEMA4. gr J _. _ lb Protection RatingPxxxsseries _ __IP68J NEMA6P a,/ib ... 0-100 %.. Relative Humid ty - -- - PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V ASOLAREDGE INVERT€RI'I Minimum String Length g ',, 10 18 ...... (Power Opti izers) .. .. .. M imum String Length 25 25 50 PIT power optimization at the module-level (power optim zers) 5250 6000 12750 W Up to 25%more energy Maximum Power per String ,.. _... --. -- Parallel Strings of Different Lengths yes Superior efficiency(99.5%) ororientatlons Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading g Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module level voltage shutdown for installer and firefighter safety i Www.SO dre`Uge.Us Mono Multi) Solutions _...... ........'TSMmPC05 .. 1 TSMmmPA05 i E S I. SOUJTION Module can becir snow loads up to 540OPa and 24 W wind loads kip to 240OPa .r` C aa.Jaraantea�d poweroutput - .,; � r - w , under bwrw° DlgN �:c:ar'Ictitic�sns �Cloudy days, mornings and evenirigs LINEARlndlE)penden ly cr,rtii"ued k:,q k'il °r-ria iona::al a., riltu<,a.a'boa�w�Y taaadww es IEC61 1 , tEC61730, Ui170 ,TUV Safety Class ti, C ......... _.... ___._w ....__.. I ............................... ---- _.......... --...... Y=rsroaaded in W7,'Ifrin a"nrrokv is r°a rcaftally+ hag. cde a i h"rA nav:ureuwsduc 6u.urrar snvdv^d in r."asrreyyrsa+ey Ihaars a"a;9,r47aan9y aar':B'uo+,v+aa'd<:an a rruta ;'luraara aa'aflcr lra 9Ytamalaru l , rrl"t Yri : adrpcares;0augavavrprrsand<:Yr c the xawmbiyuAhigh quality rraeaaea, Cdd _rMrCPttTenl /amagetlBdi S)sien') SCiPdCrs using ofl i rncaa a d 6nutcyeidllne larTaacy , ysat utyytVjhe � � 10901, IS0400I r°unn ucA%n'-,d mrvnep lcAes rc'ca:aayd e caapacily of appoximMedy 9.9P.W."1`rin asolcur'„ wide mnge of products aaIG Wed in ie sh:.Benfid,a:Nv-nw cJc.8,ire'aaaro.ushinY and pxuaa'>k uu ity aagsp'AicoVaons lhrc,ro.aaian(a Um va✓rarlc:a. a,MY by rraaa$eafio(ng cm efficle un#c'ac°)m- n Ouuo,w ifl)parcavre n pedominance p<-,dominancevviflLINEAR PERFORMANCE WARRANTY6 we,as tin Mushy aue 4olc,vse-2 q;padaa gerari'iy, . _ And c:u1Nna:a olo:r we have dsoffi. 10 Year Product Warrardy,n .5 Year Lln a'ar'PowlCyu Warranty 3100% MrIn Selma p naffed «step' mrbr�ap v. va^wrva+lao�ucu velrura.cer9� �9p7. +raareayre�arr'��larz��naP�r° O Trimasolar Years 5 10 15 20 25 The pia'awuarbehind li paaaac:,.tl ndmtrystmndzrd lm� 6ruao"rr,ldt �N0 ��� � ���� � ����� �� �� m � w � =� ��� ^."".^""" °=", SOUARMONKNQTTechn~caU Datasheet Pub 1oou 7 SOLAR%8OUN7[ Module Connection Hardware............................................................ � Bottom UpModule Clip................................................................................................. / MidClamp ....................................................................................................................2 � End (�baOlp—..—..--.—~--.--.--^---_--..—.—_--.'—~—_'.~.—.- SOLARMOUNT Beam Connection Hardware................................................................3 L,Foot........................................................................................................................... 4 S0/L�JR�|��KJNT Beams.................................................................................................... SOU ARMONUNTMod0Ke Connection Hardware ��LARMOUNT' B�,,",AWM 1��p Mad�,, �e C�ji;') Part 302000C Washer , Bottom UpClip material: One ofthe following extruded aluminum oUuya: GOO5-T5.G10b-T5.8UG1-TG � Ut no _ ,P IP Ultimate tensile: 38kei.\1e|d: 35 koi , Finish: Clear Anodized " Bottom Up Clip weight:-0.031 lbs (14g) ^ /A|uweb|aand design loads are valid when oompono�xare 8V ^^ assembled with SOLARN1DUNTseries beams according ho authorized UN\RACdocuments | ~ Assemble with one%^-2OASTM F5A3bolt,one W'2OASTM F5Q4 ! � serrated flange nut, and one%,�flat washer ^/' ~ Use anti-seize and tighten to1Oft-lbs oftorque Resistance factors and safety factors are determined according to part 1section Qofthe 2OU5Aluminum Design Manual and third- party haa\vunu|tofromon |ASeoomdited|ebonatory Module edge must bofully supported bythe beam � w NOTE ONWASHER: Install washer nnbolt head side ofassembly. DONOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, r 1 24 Tension,Y+ 1566(6967) 686(3052) 2.28 0.662 � r :~�- � uTransverse,X± 1128(5019) 329(1463) 3.43 497(2213)1m ' �x e~ � Dimensions specified minches unless noted � � | �� �JU� �� �� ��� � �U��� ����� �� �� m � = � =� =�� � SOUAR0QOUNT Beam Connection Hardware � �(, ARM0IIJ)N'T fi,-~�cwt Part No, 304(X)OC' 3(,4000f)I � , L-Footmaterial:Onon[thandlowingoxtrudadaluminumalloyo:OUU5 � T5.8105-T5.6081-T6 ^ Ultimate tensile:38hei.Yield:35kei � " Finish:Clear urDark Anodized " |-Fuo!weight:O.21hlbs(98Q) � ^ Allowable and design loads are valid when components are assembled with GOLARK4OUNTeehao beams according to authorized---- Olt UN|RACdocumonto � L'Fmot ^ For the beam tmL-Fwotconnection: � ^Assemble with one ASTM F583W-18hex head screw and one � rrate ASTM F5g4W'onnahmdflange nut Flange N ~Use anti-seize and tighten\o30ft-lbs oftorque ^ Resistance factors and safety factors are determined according mpart 1section 9ofthe 2OO5Aluminum Design Manual and third-party test Y results from anIAS accredited laboratory � NOTE' LmodsormQivenfor the L-Foo{tobeam connuchonon|y'' he *~x ' | sure bocheck load limits for standoff,lag screw,orother � ^ attachment method ,."' Applied Load Average Safety Design Resistance ^xSLOT FOR Direction Ultimate Allowable Load Factor, Load Factor, mWvWA° U � � ,- ��--,'| " ~ ~" - Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) , 707(3144) , 2.631 1069(4755) , 0.5751 Dimensions specified in inches unless nmou I compression,Y- 3258(14492) 1 1325(5893) 1 2.461 2004(8913) 1 0.6 1 Traverse,X± 486(2162) 1 213(949) 1 2.281 323(1436) 1 0.6 � � � � � � � Ez M, ount L Foot,,PatentPendlng for Shingle Roofs pi �a r u Y � f# • X ll in One Raaf (Flashing & Mount • Mounts with all standard Racking Systems • Stainless Steel Lag Bolts and w � • All Aluminum • Easy to Install 4 1915 E 5th St., Ste. C SUNK fes_ _`r Vancouver, WA 98661 Phone: 360-335-3037 www.sunmodo.com Salesperson Name: Trinity Heating&Air,Inc.D/BIA Trinity Solar 20 Patterson Brook Road,Unit#10 west Wareham,MA 02576 Phone:(508)291-0007 Fax:(508)291-0040 j FEIN 22-3292324 MA Home Improvement Contractor Reg.Number: 170355 SOLAR (Contract Expiration Date:10/12/2013 PHONE DATE gC' 'ATATE'AND,Z'.P BMITTED TO 12/18/14 & Katie Larson JOB NAME ott St ADDRESS CODE MA 01845 or We hereby propose to furnish materials and labor necessary for the completion of OPTIONS 6.63 kW Roof mounted Solar Electric System 25 year warranty on Panels 12 Year warranty on Inverter 5 Year warranty on all miscellaneous parts and labor Customer responsible for cost of town permit fees.Trinity to obtain all permits. Customer responsible for any tree removal required to qualify for CEC rebate incentive. Required Permits-The following building permits are required and will be secured by the contractor as the homeowner's agent,at the customer's expense[if applicable).(owners who secure their own permits will be excluded from the Guaranty Fund provisions of MGL chapter 142.4.) Start of job will be within 10 days of receipt of all municipal, county, state, utility companies or any others required and shall be completed within 30 days of commencement.Buyers acknowledge and understand that the contractor cannot commence work until receipt of permits. WE PROPOSE hereby to furnish materials and labor—complete in accordance with above specifications,for the sum of: Twenty--;x thousand, six hundred fift -two and 60/100-------- dollars($ �'_�—� Payment to be made as follows: (Must Indicate total contract price and detailed payment schedule;deposit can't exceed 1/3 of contract price and payment in full can't be demended until contracted work Is completed. 500 dawn anticlDated state reb to of$1250' $12 451 30 due at beainnina of installation $12 451 30 di to at cor�IDletion of installation Permit ees a en All contractors and subcontractors must be registered by the Director of Home Improvement Contractor Registration, to a ration d1any inquiries about a contractor or 0 Park Plaza,Room 5170,Boston,MA 02116 orbyby calling 617 -973-8787 or 1-888-283-3757 directedould be to the Director 1 888 283-375 at All material is guaranteed to be specified.All work to be completed in a substantial workmanlike manner according to specification submitted,per standard practices.Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders,and will become an extra charge over and above the estimate. All agreements contingent upon strikes,accidents or delays beyond our control. ACCEPTANCE OF CONTRACT The above price,specifications and conditions are satisfactory and hereby accepted. You are authorized to do the work as specified.Payment will bLmade NOTICE TO RETAIL BUYER: Alit YOU MAY CANCEL THIS AGREEMENT IF IT HAS BEEN Signature SIGNED BY A PARTY HERETO ATA PLACE OTHER THAN AN ADDRESS OF THE SELLER,WHICH MAY BE HIS MAIN Note:Thls contr t ma e OFFICE OR A BRANCH THEREOF,PROVIDED YOU NOTIFY withdrawn by us f not a pled w hi 3 days. THE SELLER IN WRITING AT HIS MAIN OFFICE OR BRANCH Do not sign this contract f the are ny bl nk spaces BY ORDINARY MAIL POSTED,BY TELEGRAM SENT OR DELIVERY,NOT LATER THAN MIDNIGHT OF THE THIRD BY BUSINESS DAY FOLLOWING THE SIGNING OF THIS Signature AGREEMENT. SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. 12/18/14 signature_ Data of Acceptance �^"" A.Meanings."You"and"Yours"refers to the buyer or ties certificates and rebate forms if applicable.Warranty buyers."We","Us"and Trinity Heating&Air,Inc-refers to service shall be provided Monday through Friday during nor- the seller. mal business hours.Emergency service is available after B.Main Office Approval.All contracts are subjected normal business hours at after hour rates.You hereby to approval by our main office.if our main office rejects agree no warranty service will be furnished to you H you such a contract, it is validly cancelled without further owe us any balance not paid in accordance with our responsibility on our part, except to return any money credit terms.We shall not warranty nor shall be respon- paid under this agreement.This order when accepted sible for any pre-existing defects of components or stru by us and you constitutes a binding contract covering all cture defects in the home. The purchasers are agreements expressed or implied in the agreement on responsible for obtaining all permits necessary for the this and the opposite side of this page,and that no other work to be performed.Unless specifically stated,the war- agreements oral or written expressed or implied shall ranties for labor are to the person(s)signing this contract. limit or qualify the terms of this contract. Warranties are not-transferable. C.Grant of Security Interest and Contractors Right H.Consumer Credit Contract Notice. If this docu- of Possession.If you,the buyer decide to finance any ment applies to a consumer credit contract this notice part of the purchase price through us, you grant us a applies. security interest in the equipment sold hereunder and Notice. Any holder of this consumer credit contract. authorize us to file financing statements without your is subject to all claims and defensive which the debtor signature.In addition to our right as a secure party,we could assert against the seller of the goods or services may also have the right in addition to all others,we pay obtained pursuant hereto or with the proceeds hereof. possess at any time for credit reasons, or because of Recovery by the debtor shall not exceed the amount paid your default to withhold the equipment delivery in whole to the debtor hereunder. or in part,and to retake and repossess all equipment and I.Entire Agreement.We will only do the work that is component parts that may have been delivered to you stated in this contract.The only way to change it is in without the necessity of taking any other proceedings, writing on a document known as a change order signed and you consent that all equipment and components by both you and us. parts retaken or repossess shall become the absolute J.Compliance with Law.This document is intended property of us provided that you are given full credit to comply with all applicable laws and rules.This includes thereof.The foregoing shall not be constructed as limit- federal,state, and local laws and rules of every kind. If Ing in any manner,any of the rights or remedies available any provision or part does not meet any such require- to us because of any default by you under the Uniform ment that part will be considered to be ineffective or to Commercial Code as in force and effect in the state of be changed to meet such requirement.The rest of this New Jersey on the date of signing of this agreement, contract still stays in effect. Upon any detail,we may charge and you agree to pay K.Transfer. You cannot transfer your or our duties any and all attorney fees and other costs incurred by us under this contract to any other person without written taking and selling the equipment or collecting any bal- consent by us. ance due including interest at the highest legal rate. L.Successors.This contract binds your heirs,execu- D.Access,You will permit us to go into the premises. tors,and administration. The premises include the land and the building.You will M. Buyers Refusal to Purchase. If you refuse to get consent needed for us to go into any other premises complete your purchase,you understand that you may be in order to do the installation.If we are not allowed to go responsible for any other damages which you may incur onto the premises and are prevented from completing as a result of your failure to perform your obligations the work,then we shall have no duty including interest at under the terms of this agreement.We shall be entitled the highest legal rate. to retain the deposit as liquidation damages. E. Debris.The homeowner agrees to be responsible N.Non-Payment. If there is an overdue unpaid bal- for the cost of removal of any trees,shrubs,foliage and ance,you will pay us interest at the prevailing rate.If we the like to qualify for any and all state rebates. place the account with an attorney for collection,you will K interference with Performance.We are not respon- pay our attorney's fees plus any other costs or expenses sible for any delay or interference with performance for of collection.The amount of the attorney's fees to be paid reasons beyond our reasonable control. Such interfer- by you to our attorney shall be no less than 20%of the ence shall be but not limited to any delay in delivery or total balance due. failure to deliver materials, labor troubles, strikes, lock Law of State of New Jersey shall govern this con- outs, war, riots, insurrection,civil commotion, failure of tract. supplies from ordinary sources, fire, flood, storm, acci- dent,or any act of God or caused beyond its control. G. Warranties. The only warranties which apply to labor or materials furnished under this contract are those in the warranties certificate furnished by the manufac- turer or by us.We agree to extend to you any standard and extended manufacturers warranties as may apply. You shall be responsible for the completion of all warran- The purchaser has read,understands and agrees to all the provisions contained in the Contract and acknowledges receipt thereof. Signature Signature Trip ity . SI-AR HOMEOWNERS AUTHORIZATION FORM I Derek Larson (print name) am the owner of the property located at address: 20 Abbott Street (print address) I hereby authorize Trinity Solar, and their subcontracting company Boston Solar , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. S ncer y 20 Abbott St Homeowner's Signature Street Address Derek & Katie Larson No. Andover MA 01845 Print name City,State,Zip Code 312-286-8236 Phone Number Client#:103109 BOSSO DATE(MMIDD/YYYY) ACORD. CERTIFICATE OF LIABILITY INSURANCE 1/13/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND COR ALTER ONFERS NOTHE COVERAGE AFFORDED Y THE IGHTS UPON THE CERTIFICATE HOLDER. DEPOLICIES S CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed.If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT Pe J.Merati PRODUCER NAME: Pegg 844 702-8075 people's United Ins.Agency CT PHONE Ext:860 524-7624 Arc No One Goodwin Square EiM..Lss: peggy-merati@peoples.com NAIC# Hartford,CT 06103 INSURER($)AFFORDING COVERAGE 860 524-7600 :HDI-Gerling America Insurance C 41343 :Merchants Mutual Insurance Co 23329 INSURED The Boston Solar CompanyLAr!:!;BzER:: 55 Sixth Road,Suite 1 : Woburn,MA 01801 : COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: E INSURED UNIED/IBOVE ITHIS IS TO NDICATED. NOTWITHSTANDING I FIA AI ING ANYCREO�IREMENT TERMF INSURANCE OR DCONDIIT ON OFBELOW HAVEANY CONTRACT ORBEEN ISSUED TO HOTHER DOCUMENT WITH RESPECT ETO WHICH POLICY PERIOD CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN PRED YCE�D BY OL PAID EXP CLAIMS. LIMITS TYPE OF INSURANCE TR AINSR WVD DDLSUB POLICY NUMBER MM1DD MMIDD A GENERAL LIABILITY EGGCC000153814 0/0312014 01/01/201 EACH OCCURRENCE $100,0000 RENTED ,0 FAME MISES00 Ea occurrence X COMMERCIAL GENERAL LIABILITY MED EXP(Any one person) $ CLAIMS-MADE M OCCUR PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 PRODUCTS-COMP/OPAGG $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: $ POLICY MX JEC LOC COMBINED SINGLE LIMIT 1,000,000 A AUTOMOBILE LIABILITY EAGCC000153814 10/03/2014 01/01/201 Ea accident EAGCC000153914 10/03/2014 01/01/201 BODILY INJURY(Per person) $ A X ANYAUTO BODILY INJURY(Per accident) $ ALL OSCHEDULED AUTOS PROPERTY DAMAGE $ AUU TOSS NON-OWNED Peraccident X HIRED AUTOS X AUTOS $ B X UMBRELLA LIAR X OCCUR CUP0001367 1010312014 01/01/201 EACH OCCURRENCE $5 000000 AGGREGATE $5 000 000 EXCESS LIAB CtAIMS-MADE I $ DED X RETENTION$10,000. '' I 1/14/2015 01/14/201 X wcsTATu- OTH- A WORKERS COMPENSATION '' EWGCC000153815 — T $1 000 AND EMPLOYERS'LIABILITY Y I N E.L.EACH ACCIDENOOO ANY PROPRIETORIPARTNER/EXECUTIVE E.L.DISEASE-EA EMPLOYEE $1.00000 OFFICERIMEMBER EXCLUDED? D N 1 A (Mandatory In NH) E.L.DISEASE-POLICY LIMIT $1,000,000 It yes,descnbe under DESCRIPTION OF OPERATIONS be DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) RE:Permit Work Certificate Holder is included as Additional Insured per the terms,conditions and exclusions of the referenced general liability and umbrella policies,if required by written contract or agreement. CANCELLATION CERTIFICATE HOLDER SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of North Andover THE EXPTION ACCORDANCE WITHTHEHEREOOF, NOTICE cy PROVISIONS.ILL BE DELIVERED IN 1600 Osgood Street North Andover,MA 01845 AUTHORIZED REPRESENTATIVE ©1988-2010 ACORD CORPORATION.All rights reserved. ACORD 25(2010105) 1 of 1 The ACORD name and logo are registered marks of ACORD SMGCT #S5656471M565467 The Commonwealth of Massachusetts -'° Department of Industrial Accidents - ; office of Investigations w 1 Congress Street,suite 100 Boston, MA 02114-2017 wruitr.tnass.gov/dia umbers Workers' Compensation Insurance Affidavit: Builders/Contractors/ElePlease Print Le ibl A licant Information Name (Business/Organization/Individual): The Boston Solar Company _ Address: 10 Churchill Place 617-858-1645 City/State/Zip:Lynn, MA 01902 Phone#: ---- Are you an employer? Check the appropriate box: Type of project(required): 20 4. [] I am a general contractor and I 6 ❑New construction 1.a I am a employer with_______ have hired the sub-contractors employees (fitll and/or part-time).* 7. Remodeling listed on the attached sheet. ❑ 2.❑ I am a sole proprietor or partner- These sub-contractors have 8, [1 Demolition ship and have no employees employees and have workers' 9. ❑Building addition working for me in any capacity. comp, insurance.$ [No workers' comp. insurance 5 ❑ We are a corporation and its 10.❑Electrical repairs or additions required.] officers have exercised their 1 l.❑Plumbing repairs or additions 3.❑ I am a homeowner doing all work right of exemption per MGL 12.F1 Roof repairs myself. [No workers' camp. c. 152, §1(4),and we have no 13.� atlaerSOlar insurance required.] t employees. [No workers' comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. vit t Homeowners who submit this must affidavitindicatingan additional doing shoall wing g therk dthen name o're f the sub-contractors and state whether or not those entities}ave such, utside contractors must submit a new affida tContractors that check this box must a employees, if the sub-contractors have employees,they must provide their workers'comp.policy number. jam an employer that is providing workers'compensation insurance for in),employees. Below is the police and job site inforniation. Insurance Company Name:HDI-Gerling America Insurance Company E:WGCC000153815 Expiration Date:1/14/2016 Policy#or Self-ins. Lic. #: City/State/Zip: earth Andover„MA 01845 Job Site Address: 20 Abbott Street Attach a copy of the workers' compensation policy de laration MGI. pas 2 can ORDER t ing tithe imposition of clicy number riminal n nal penaltiexpirationeaof a Failure to secure coverage as required under Section fine up t$1,500.00 and/or one-year imprisonment, as well ascivil penalties thistatement inthe form may f forwardedOP WORK to the ffice of d a me of up to$250.00 a day against.the violator. Be advised copy Investigations of the DIA for insurance coverage verification. penalties of perjure that the information provided above is true and correct. y f3 - rns and. ..,..,,.. 1 do hereby certify under t a 6/9/2015 Dat e: Si ature: Phone#: 6178581645 - Official use only- Do"Of write in this area,to be completed by cit V or town offrcra . Permit/License # City or Town: Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.other Phone#: Contact Person: a ` '/X V e NAd MAS S-J4n'A eelW h' �rt'A.J,4ka'4�VdA,an?"aS,k Office of Consumer AlTairs Xc Business Regulation License or registration valid for individui use only before the expiration date. if found return to: ., ME IMPROVEMENT CONTRACTOR i �Nr 9istration. 169658 Type: Office ofConsumer Affairs and Business Regulation �� ar xpiration: 7/27/2015 LLC 10 Park Plaza-Suite 5170 ° e Boston,MA 02116 THE BOSTON SOLAR COMPANY LLC ROMAIN STRECKER 10 CHURCHILL PLACE _ LYNN,MA 01902 Undersecretary retar �.,�� � Not valid without signature Massachusetts wDepartment of Pubhc Safety Board of BuMing RegWationsand Standards Cuiruw�0.NCVfaon "�Giiw4%kao'R i Li : rt . CS-096385 ROMAIN D STRke �o l� 10 CHURCHILL PLA rFA LYNN MA 0190 o-' Conymsswer 10/08/2016