HomeMy WebLinkAboutCorrespondence - 0 BRADFORD STREET 5/6/2002 Departmental Referral Form for Special Permits
'To: Director,Engineering, JA$ , _1��n-� ✓
Fire Chief 44. 1/
Conserva�Cion Adhiinistrator, Brian LaGrasse
Open Space Committee (Sub-Committee of Con Com)
Building Commissioner, Bob Nicetta E/
Health Administrator, Sandra Starr
School Committee
Police Department
From: Planning Department
Date: {�1cC,y , 2_e7p Z
Re: _ Special Permit
Site Plan Review
Address/Development .b1h 2,
A Public Hearing has been scheduled for �Utl L
to discuss the plans checked above. (Preliminary pl4ns do not require public hearings.)
Please provide your written continents to the Planning Department by f Z
(Wednesday before the scheduled public hearing and/or scheduled Planning B and meeting).
Failure to provide written comments by this date will constitute your approval ofthis plan.
Thank You.
PUBLIC HEARING NOTICE
NORTH ANDOVER PLANNING BOARD
In accordance with the provisions of M.G.L. Chapter 40-A, Section 11, the North
Andover Planning Board will hold a public hearing as follows:
Purpose of Public Hearing: Application for a Watershed Special Permit under
Section 4.136 and a Common Driveway Special Permit
under Section 2.30.1 of the North Andover Zoning
Bylaw to permit the construction of a single family
home, shared driveway, utilities, fieldstone walls and
site grading.
Applicant/Petitioner: Tara Leigh Development LLC
185 Hickory Hill Road
North Andover, MA 01845
Address of Premises Affected Lot 3-Bradford Street
Assessors Map and Lot: Map 62 Lot 138
Public Hearing Date &Time Monday May 20, 2002 7:30 p.m.
Location of Public Hearing North Andover Public Works Garage at 384 Osgood
Street, near the High School entrance
Information Available A copy of the plan and application is on file in the
Planning Board office at 27 Charles Street, North
Andover, MA, and may be inspected Monday through
Friday 8:30 a.m. to 4:30 p.m.
Any person interested or wishing to be heard on the proposed plan should
appear at the time and place designated above.
John Simons, Chairman
North Andover Planning Board
Publish: Eagle Tribune Friday May 3 and May 10, 2002
TOWN OF NORTH ANDOVER
DIVISION OF PUBLIC WORKS
384 OSGOOD STREET
NORTH ANDOVER,MASSACHUSETTS 01845-2909
J. WILLIAM HMURCIAK,DIRECTOR,P.E.
�30RTl�
Robert E. Beshara, P.E. o= ay'' °� Telephone (978) 685-0950
Director of Engineering * ; Fax(978)688-9573
* z e�
11 °wwre°tt��y
�SSACHUS��
MEMORANDUM
DATE: May 20, 2002
TO: Jacki Byerley
North Andover Planning
FROM: Bob Beshara
Director of Engineering
RE: Hawk Ridge—Phase II
The Division of Public Works has reviewed the subject plans dated April 10, 2002 for Lot 2: Watershed Special
Permit, Lot 3: Watershed Special Permit and Common Driveway Special Permit, and Lot 4: Watershed Special
Permit, Common Driveway Special Permit, and Access Across Street Frontage Special Permit, and offer the
following comments:
General.
Provide easements for the common driveways,water and sewer utilities,drainage,retaining walls and other common or
shared features.These easements need to provide for maintenance,repair,and inspection. Given that these items are in the
Watershed Protection District,these easements must also provide access for inspection and repair of these systems by the
Town should the owners fail to provide repairs deemed necessary by the Division of Public Works in support of health or
safety issues.
Provide driveway entrance details,grading plan and proposed radii for driveway curves at the intersection with Bradford
Street.
Drainage:
Drainage calculations and pipe sizing are required for the 12"site drainage piping.
Drainage calculations and basin sizing is required for sizing of leaching basin.
Drainage calculations and pipe sizing are required for the 12"driveway culvert pipes at Bradford Street.
Revise driveway profiles to insure that no driveway runoff directly enters onto Bradford Street.
Provide drainage calculations,construction details and outlet destination for the runoff to be discharged into the ditch/swale
adjacent to Bradford Street.
Provide construction details for the proposed foundation drainage.
5-20-02 Special Pennit Application -1-
. -------- L•lY!-1I vno IVV. t-.If
TOWN OF NORTH ANDOVER PLANNING BOARD
REVIEW OF SPECIAL PERMIT APPLICATION
FOR CONFORMANCE WITH THE TOWN OF NORTH ANDOVER
ZONING BYLAW&STANDARD ENGINEERING PRACTICE
Location: Hawk Ridge Phase H VHB No.: 06716.55
Owner&Applicant: Tara Leigh Development,LLC
185 Hickory Hill Road,North Andover,MA 01845
Applicant's Engineer: MHF Design Consultants
103 Stiles Road,Suite 1,Salem,NH 03079
Plan Date: 04-12-02 Review Date: 05-15-02
The Applicant submitted a plan,special permit application and supporting documents to VHB for review.
The special permit submission was reviewed for conformance to the appropriate sections of the 1972 Town
of North Andover Zoning Bylaw as amended May 2001 and standard engineering practice. The following
comments note non-conformance with specific sections and questionstcomments on the proposed design.
VHB offers the following comments:
Section 2,30.1 Common Driveway—Lot 3&Lot 4
The Applicant should verify that a maintenance agreement between Lot 3 and 4 for the common driveway
has been submitted to Planning Broad for review.Also,will a common driveway be required for Lot 1 and
2?
Sec"4.136.4 Watershed Protection District
1. (4.c.iii)This section requires that a written certification regarding the quality and quantity of water
entering Lake Cochichewiek should be made by a registered Professional Engineer or a scientist
educated in and possessing extensive experience in the science of hydrology and hydrogeology.It
appears that a written certification in the special permit application was made by a registered
Landscape Architect,not by a registered Professional Engineer.VHB recommends that a written
certification be wade by a registered Professional Engineer.
2. (4.c.iv) This section requires that a reasonable alternative location outside of the Non-Disturbance or
Non-Discharge zone be investigated. It appears that the Applicant could locate the proposed houses on
Lot 3 and 4 in the Town of Boxford outside the Non-Discharge zone.The Applicant should justify why
there is no reasonable alternative location outside the Non-Discharge zone for the proposed houses.
3. (4.c.vi)It is not clear how the Applicant proposes to limit the application of fertilizer by private
homeowners through the conditions of Special Permit Approval.Will the conditions of Special Permit
Approval be included in the property deed?VHB requests that additional explanation be provided.
Section?Dimensional.Uguwements
It appears that Lot 1 and 2 do not meet the minim=frontage dimension of 175 feet.Has a frontage
exception been submitted to Planning Board for approval?For clarity,VHB recommends that the entire
parcels of land be shown on the larger scale of plans.
Drainase Comments
It is not unclear whether test pits or percolation tests have been performed to verify existing soil infiltration
rates and existing groundwater elevation.Since the majority of the driveway is in a"cut section",VHB
recommends that test pits and percolation tests be performed to verify that the proposed driveway
infiltration trench system will function as designed.
1
7:\067rf 55\does\cepoies\Fiawk lttdgr Y<Sp Permit lteview-0519A?.dtx
. ------ VN15 No.995 P.3
It is recommended that the Applicant provide WRITTEN RESPONSES to the issues and comments
contained herein.
Reviewed by: �� �4 Date: oz.
Danny H.Wong,E.I.T.
Project Engineer-Highway and Municipal Engineering
Checked by: IZASA a,4
Timothy B.McIntosh,P.
Project Manager--Highway and Municipal Engineering
2
I:\0671655\docd\report9\MwkMdge J1 by Permit Aevulw-091402.doc
Town of North Andover
Office of the Planning Tie paftmen
Community Development and Services Division
27 Charles Street
forth. Andover, MassachuseLls 01845
Telephone(978)688-9535
Fax(978)688-9542
MEMORANDUM
TO: North Andover Planning Board
FROM:Jacki Byerley,Interim Assistant Town Plannell
RE: Lot 3 Bradford Street-Watershed&Common Driveway Special Permit
DATE: May 14,2002
This proposal is for a single family home and common-driveway to be shared with the adjacent Lot 4 located
within the Non-Discharge Zone. An ANR plan was submitted on May 22,2001 creating the lot.
My review is as follows:
1. The driveway entrance and dwelling will be located in North Andover. The parking portion of the
driveway is located in Boxford, the developer should state whether a permit will be required from
Boxford for this.
2. The applicant proposes to have water and forced main line from Bradford Street to service the home.
3. The lot has a total square footage of 756,549 within the R-1 Zoning District. The requirement for
that district is 87,120 SF.
4. A single-family dwelling and shared driveway are allowed uses with the R-1 Zone.
5. A roof infiltration system is proposed at the front of the home.
6. The applicant has demonstrated that clearing of the lot is kept to a minimum to cause less alteration
to the site as a shared driveway is proposed.
7. Wetlands have been Ragged and haybales are proposed along the limit of clearing and outside of the
Non-Disturbance Zone.
8. Catch basins and an infiltration trench are proposed.
9. An easement and maintenance agreement needs to be provided for the common driveway.
10. The applicant needs to demonstrate how far from the annual mean high water mark of Lake
Cochichewick the lot is.
The applicant has stated on the plans that the lots are located in the Flood Plain District Zone A in accordance
with Section 4.137(5)a. the applicant must provide certification by a registered professional engineer that the
construction will not result in any increase in flood levels during the 100 year flood with the Building
Commissioner and Director of DPW in agreement.
130AR 1)OF APP FALS x"88-9541. BUILDING 688-9545 CONSERVATION 688-9530 HFAUH698-9540 PLANNING 688-9535