HomeMy WebLinkAboutCORRESPONDENCE/PEER REVIEW Town of North Andover o Ho pTH ti
OFFICE OF 32 h t. o L
COMMUNITY DEVELOPMENT AND SERVICES p
146 Main Street
�AAifo•IP`y.�5
KENNETH R.MAHONY North Andover, Massachusetts 01845 9SSACHUS�t
Director (508) 688-9533
Fax Transmittal Sheet
To:
Fax #
From: Kathleen Bradley Colwell, Town Planner
Date: X eCpyy)bey- :C'- � �q 95
Re: Cc OU C-n�ky-\-/
V2r1
C OON - . {'CSC nC-S - C'EZ`E E
1 1_ 1 Cpl Cx1 > V�(1 Ci a tr1C�
Total number of pages (including cover sheet) ,
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Julie Parrino D.Robert Nicetta Michael Howard Sandra Starr Kathleen Bradley Colwell
R CLlY�:.'.,
DA L0 G
NORTH A,iAY R
DECEMBER 16, 1985 DEC
Conditional Approval
Coventry Estates ^
Definitive Subdivision
DEFINITIONS SECTION
Developer: shall mean Coventry Development Corporation, 1.00 Lindbergh
Avenue, Methuen, Ma and its successors .
The Board: shall mean ' the Planning Board of the Town of North
Andover, Ma.
The Rules: shall mean the Rules and Regulations Governing the
Subdivision of Land - North Andover , MA. issued by said Board and as
amended through this date.
The Plan: shall mean sheets one through four. , grading plan sheets
1-4, plan & profile sheets 1-9 of the Definitive Plan of "Coventry
Estates" prepared by Beta International, Inc . , dated July 1985 revised
November 8,
1 . The pending Notice of Intent presently before the North Andover
Con6.ervation Commission shall be the determining factor regarding
restrictions on wetland work within the subdivision. The
applicant shall be governed by the Commission under M.G.L. Chapter
131 - Wetlands Protection' Act, and the local. Conservation
Commission ' s local regulations . Any changes required may be cause
for reconsideration of the subdivision under M.G.L. Chapter' 41 .
2 . If the Conservation Commission institutes, or recommends any
changes to the approved definitive plan, the applicant shall
submit all information to the Board for review of any major
revisions which may be considered for modification under Chap.41 .
-- - 3. Iya accordance with the Conservation Commissi.on ' s comments and
me4orandum dated December 10, 1985 :
that, the portion of the subdivision fronting on, Dale Street,
specifically Lots 1 through 5 that is within 100 feet of the
wetland tributary, may have restrictions imposed rendering these
lots.. unbuiTdable. These lots will not be released from the
restrictive covenant until the time in which all permits have been
approved. Copies of all approvals and plans shall be submitted to
Board for approval .
- Due to steep slopes on lots 17 through 30, both temporary and
permanent erosion control and stabilization measures shall be
implemented during and after construction. Mitigating plans
stipulating erosion control shall be submitted for approval .
4. The Planning Board will. require a bond in the amount of $126 , 000
or $3,000 per lot to cover erosion control measures during
construction. If the erosion measures are deemed inadequate to
provide for the necessary control measures , the Board wil_1
cvarni ca +-ha ccar+iiri i-v to cfiahl i 7.P tl1P_ nrnhl em area .
1 �
�AF,I L I,f's;i; ,
Coventry Estates NORTH A16JO ER,
Definitive Subdivision DEC 11 ' yg �U5
- J U
5. Conditional approval of this subdivision does not imply
pre.-approval of any other outstanding permits , specifically those
associated with Section 4 . 133 of the North Andover Zoning Bylaw -
Watershed District Special Permits or Variances .
6 . Hydrants shall be within 500 foot intervals with a hydrant to be
located at the intersection of Dale Street and Coventry Lane.
7 . A 50 foot buffer strip shall remain around the periphery of the
subdivision in its natural state along Lots 3 through 16, with the
exception of drainage and utility requirements . This buffer strip
shall be placed on the deeds of each lot prior to conveyance.
*to be noted on the covenant and recorded plan. Copies of
proposed deed restrictions shall be submitted for approval_ by the
Board .
8 . In order to minimize or eliminate wetland disturbance due to
associated drainage structures, the developer may seek the option
of constructing a dike on Town Farm Land behind Lot 16 , subject to
review and approval from the Conservation Commission and
Selectmen. No construction shall occur until approval is received
and the Board is notified.
9 . Per Section 4 . 133 Watershed District, no burying of tree stumps
and other debris will be allowed in that portion o-f the
subdivision *ithin the Watershed District. For that portion of
the subdivision outside of said District shall have a certified
plan by a land survyor submitted to the Board and Highway Surveyor
for review and approval prior_ to any on-site utility or, road
construction.
10. No open burning is permitted, except that allowed by the North
Andover Fire Department.
11 . Lot numbers shall be posted during construction, and house numbers
shall be posted prior to occupancy.
12 . The pump station on Dale St . shall be relocated to a site with the .
--- lowest possible natural elevation which is near the northeast
corner of Lot 15 with the approval of the Board of Public Works .
13 . Cleanouts shall be provided on the Dales St . force main at sta .
7+93 Orchard Path and on Dale St . at sta. 203+50 , 214+50, and
222+0 .
14. Thd sewer line between sta . 10+0 Orchard Path and 0+08 Coventry
Lane shall be shown on the profile sheet .
P
RECEIV:F0
DAHI1:L L_CHG
NORTIi A DOYER
Coventry Estates
Defintive Plan OEC 19 1 45 P 85
15 . The plans shall be modified to show the existing 12 inch water
main on Dale Street and South Bradford Street :
- South Bradford / Dale Streets
twelve inch class 52 ductile iron pipe installed -15 feet from the
northerly property line with 5 feet of cover below the finish
grade, to be extended down S .Bradford St . to Dales St . with
hydrants every 500 feet and division gate valves every 1000 feet.
The Dale Street main shall be extended on Dale to the intersection
of S .Bradford with hydrants every 500 feet . The water main on
Dale shall end at sta . 209+00 . (Subject to modification upon
submittal of subdivision abutting said property and review by
Public Works)
All hydrant branches shall be provided with six inch Mueller or
equal valves (open left) and comply with AWWA specifications L500
52T and will be supplied with 100 lb sliding type gate boxes
marked 'Water ' .
All water mains shall pass leakage and pressure tests performed
in accordance with section 13 of the AWWA standard C600 and shall
be chlorinated in accordance with AEEA C601 ' Standard Procedure
for disinfecting water mains ' .
- All sewer mains shall be 8 inch vitrified clay pipe installed
in the centerline of the Street.
The force main shall be installed 5 feet right of centerline on
Orchard Path and Coventry Lane 5 feet of cover below the finish '
grade and shall be ductile iron pipe.
- The gravity sewer on Dale St. shall be deepened from Appleton
St. to meet the invert of the existing manhole and shall proceed
on Dale St. at minimum grade in order to provide gravity sewer to
maximum number of existing homes . The proposed force main shall
be ductile iron pipe.
- 5 inch vitrified clay sewer services extended to the property
line shall be provided where ever an off site sewer passes an
existing dwelling.
- Precast manholes shall conform to ASTM designation C478 and
ahll meet the following additional requirements , the wall
thickness ahsll be not less than 5 inches, sections shall have
tongue and groove joints with an approved bi.tumastic gasket . Pipe
connections shall be of the rubber boot with stainless steel band
or approved equal . Manhole frames and shall be cast iron lettered
' Sewer ' and shall be eight inches high.
- A11 sewers must pass low pressure air test with a.. maximum
allowable leakage rate of 0 .0015 cubic, feet per minute per square
foot of internal pipe surface.
- k Adequate public liability and property damage insurange as well
as a street opeing bond in an amount satisfactory - to the Highway
Surveyor will be required for the work on Dale St .
Coventry Lane
—'`-Water main shall be 8 inch class 52 ductile iron pipe
i'pstalled 15 feet from the northerly peoperty line with 5 feet of
cover .below the finish grade . 8 inch Mueller or equal gate valves
(open'.-Left) shall be provided at sta . 0+0, 10+0, 20+0, 28+13 .
Eddy breakflange hydrants to North Andover specifications are to
be installed at sta. 2+10, 7+50, 11+70, 17+70, 22+30, 26+30 .
+ P
l
ro �
7oventry 'Estates
Definiti've.`PI'an
I ►,.5 PI� '85
Orchard Path
- Water main on Orchard Path shall be 12 inch Class 52 ductile
iron pipe from the easterly prperty line, with 5 feet of cover
below the finish grade . Eddy breakflange hydrants to North
Andover specifictions are to be installed at sta. 3+00 and 8+00 .
16 . The Board hereby waives the the requirements of the Rules, Section
IV, subsection A.4(a) allowing the length of the dead end street .
Although this development will not permit a looped road system
within the subdivision proposal, future connection is possible,
deeming this dead end road as a temporary condition.
__1.7 . All proposed drainage detention areas shall be noted on plans as
drainage easements. '
18 . Security shall be posted for the purpose of compliance with the
subdivision control law pertaining to ' Street Trees ' within the
right of way.
- 19 . Security in the amount of $18,400 shall be posted with the Board
to ensure satisfactory submittal of final as-built and acceptance
plans to be recorded at the North Essex Registry of Deeds after
review and approval by the Planning Board and Highway Surveyor .
20 . The applicant/owner/developer shall be aware of the fact that
approval of this subdivision under the Board ' s Rules will not
relieve said parties of the responsibility to other property
owners upon whose land may be affected by indirect or direct
development storm water discharge.
21 . Roaplway cross sections shall conform to the Rules and Regulations
established by the Board.
22 . The developer shall present to the Board prior to any construction
activity satisfactory documentation regarding earth removal
schedule and hours of heavy construction traffic . A list of' the
contractors working in the subdivision shall be forwarded to the
Board for their files .
23 . Any discharge of drainage onto Land owned by the Essex County
Greenbelt or their successors shall present a letter to the Board
stating that the Town of North Andover will. not be responsible for
the maintenance of discharge structures or overflow with approval
by Conservation.
24. In order to minimize land disruption on site the applicant shall
break the construction schedule into a phased program per Section
III ,B .h. , whereby the initial. phase will consist of work to be
done from sta . 1+00 to 16+00 . All work inlcuding stabilitzation
measures shall be completed prior to commencing into phase 2, sta .
t
Ri:CE.r., n
DANIEL LiaNG
r K
'oventry Estates "' 00VER
Oefinitive Plan DEC 45 pfj fUS
16+0 -to end . Orchard Path construction may take place in the
intia.l phase or last phase . The phasing process shall exclude
utility and drainage work. Separte completion dates shall be
instituted, for each section to be established by the .Highway
Surveyor and Planning Board . No lots shall be released from the
covenant on each phase until all drainage for each phase has been
completed and binder coat is applied. ,
25 . The street drainage on Orchard Path shall. be redesigned and
redirected away from catch basin on Dale Street and flow into a
new drainage structure on Lots 1S and 2S, with an easement running
to wetlands on said lots . This redesign will be submitted to the
North Andover Conservation Commission for their review and
approval . This modification shall serve to eliminate any drainage
from impacting the watershed of the lake.
26 .' The Half cul-de-sacs as shown on the submitted definitive plans
shall no be permitted.
27 . Lots 17 , 18, 19 South Bradford Street shall not be released from the
statutory covenant until another access route to Salem Street has
been submitted. for review to the Board and approved under M.G.L.
Ch. 41 .
28 . No more than 50 percent tree cutting on each lot shall be
permitted within the subdivision. Any tree cutting needed beyond
this maximum restriction placed upon the developer' shall appear
before the Board for approval to do so.
#45
cc:
Highway Surveyor.
Public Works
tree Warden
Police Chief
Fire. Chief
Building Insp.
Conservation
Board of Health
Assessor
File
Applicant
Engineer
,rmandeau Associates NORMAN®EAU A'SSOCIATFS
Nashua Road coien"
,gedford, NH 03110-5500
',iO3)472-5191
73)472-7052(Fax)
July 20 , 1995
Atty. Peter Hatem
127 Turnpike Street
North Andover, MA ,01845
RE: Lake Cochichewick Watershed Protection District;
Proposed Lot Development at Lot #1, Dale Street
Water Quanity and Quality Evaluation
Dear Atty. Hatem,
This letter report represents a Water Quality and Quantity
Evaluation associated with the above-referenced project consistent
with the Special Permit requirements for proposed developments
within the Town' s Watershed Protection District. The purpose of
this Evaluation was to assess whether the proposed project would
have a significant negative effect on the water quality of Lake
Cochichewick. In performing this evaluation, Normandeau Associates
reviewed the proposed site plan(dated April 12 , 1995) , conducted a
site visit, reviewed the Order of Conditions prepared by the North
Andover Conservation Commission(NACC) as well as the revised
Watershed Protection Bylaw(Oct. 24 , 1994) and the Lake Cochichewick
Watershed Plan(IEP, 1987) .
The proposed project consists of constructing a residential
dwelling on a one acre lot located on Dale Street which is in the
upper headwaters of the Batell ' s Brook subwatershed. The site is
about 1. 3 miles from Lake Cochichewick as the stream flows. Runoff
generated within the property drains into bordering vegetated
wetland along the eastern and western edges of the property which
outlet into a large wetland area on the other side of Dale Street
and then eventually into Batell ' s Brook. Soils onsite in the upland
areas have been mapped as part of the Canton-Charlton complex which
are described as a well-drained soils with relatively low runoff
potential (SCS, 1981) . The backside or southerly edge of the
property essentially coincides with the major drainage divide
between the Lake Cochichewick and the Fish River watersheds.
The Batell ' s Brook subwatershed consists of 368 acres which
make up 13 . 4 percent of the total watershed to the Lake (IEP.
1987) . At the time the Watershed Plan was developed, the principal
land uses within the subwatershed consist of forested, residential,
and pasture areas which comprise roughly 47 , 26 and 14 percent of
the subwatershed area, respectively. Without accounting for any
additional residential development that occurred in recent years,
the proposed project, using the entire lot area, would add about
1. 0 percent to the total residential area within the subwatershed.
Corporate/Northeast RMC Environmental Services Southeast and California
Bedford, NH Middleboro, MA Spring City, PA New Ellenton, SC
Drumore, PA Greenville, SC
Hampton, NH Peekskill, NY Richmond, CA
Yarmouth, ME Lakewood, NJ Brattleboro, VT
A arvision of Thermo Process Systems Inc.a Thermo Electron company -
NORMANDEAU ASSOCIATES
page 2
/ As shown on the site plan, only about 15 percent of the lot
area or 6 , 500 sf will be disturbed to accomodate the structure
footprint(1, 613 sf) , paved driveway(1, 200 sf) and associated
grading. The house will be connected to the municipal sewer system
through a new force main that will be installed along the north
side of the Dale Street right of way and will tie into the existing
sewer main several hundred feet east of the site.
The primary water quality concerns associated with this
project relate to the added nutrients, particularly phosphorus and
nitrogen, potentially contributed from various sources. Phosphorus
is of concern because of its effect on the eutrophication process
in the Lake. Nitrogen, in the form of nitrate-nitrogen, can be of
concern if drinking water contains levels above 10 mg/l. Since a
septic system is not required with this home development, one
principal source of nutrients has been eliminated. The remaining
sources relate to the potential nutrient contributions from lawn
fertilizer and soil erosion.
Based on water quality sampling results presented in the
Watershed Plan, the annual phosphorus inputs from the Batell's
Brook watershed is estimated to be 103 pounds (lbs) or about 8
percent of the total load to the Lake. Based on literature values,
contributions from residential areas are expected to range between
0. 31 and 0. 54 lbs/acre(IEP, 1987) . Using an average loading rate
of 0. 4 lbs/ac/yr, the phosphorus load from this site would amount
to about 0. 4 percent of the total phosphorous contribution from the
Batell's Brook watershed and 0. 03 percent for the entire Lake
watershed. Given the minimal site disturbance, discussed above,
and the lack of septic system inputs, loading from this particular
site would be expected to be considerably lower and would have
negligible impact on the Lake particularly with respect to the
existing residential areas within the watershed.
With respect to nitrogen, the point of concern is not so much
the lake but at the property boundary where groundwater recharged
onsite may enter a well used by an adjacent landowner. The NACC
Order of Conditions requires that only low nitrogen content
fertilizer(i.e. , generally considered to be less than 20 %) can be
used. The nitrogen content in commercially-available lawn
fertilizers generally ranges between 5 and 35 percent depending on
the manufacturer and type of material. As an example, the SCOTTS TM
Turf Builder generally contains 32 percent nitrogen with a
prescribed application rate of about 16 pounds per 5000 sf of lawn
twice a year (Spring and Fall) .
N®RMANDEAU ASSOCIATES
page 3
For purposes of estimating a worst-case, nitrate-nitrogen
concentration at the property boundary on a average annual basis,
it was assumed that fertilizer with 35% nitrogen content was
applied four times a year at 16 lbs per 5000 sf.. (As discussed
earlier, given the site plan layout only about 3700 sf would be
available for lawn area after discounting for the driveway and
building area) . This -translates into a total application of 22 .4
lbs of N per year. Most of the applied nitrogen would be utilized
by the vegetation or bound up in the soil. Previous studies have
documented minimal nitrogen losses to groundwater from turfgrass
fertilizer applications(Starr and DeRoo, 1981; Morton et al. ,
1988) . A study conducted at the University of Rhode Island found
that only 13% of the applied N was lost to the groundwater at an
application rate of 28 . 5 lbs/ac/yr and under overwatering
conditons (Morton et al. , 1988) . Again, to provide a conservative
analysis, 50 percent or 11. 2 lbs of the applied N is assumed to
enter the groundwater.
To determine an appropriate dilution volume, it was assumed
that 50 percent of the annual precipitation(i.e. , 43 . 0 inches)
evaporates or is transpired by vegetation, leaving 21. 5 inches to
infiltrate into the groundwater or travel as runoff. The soil in
this area has been mapped as the Canton-Charlton complex, which
consists of well drained soil with relatively low runoff potential
(SCS, 1981) . At a minimum, about 50 percent or 10. 75 inches of the
available water would be expected to infiltrate into the
groundwater. Additional recharge from watering is not included.
As a result, given the assumed loss of applied N and the
estimated groundwater recharge onsite, an average annual nitrate-N
concentration at the property boundary is estimated to be 4 . 6 mg/1.
This concentration based on worst-case assumptions is well below
the drinking water standard of 10 mg/1. In reality, with a low
nitrogen content fertilizer, as required, a normal application rate
of twice a year and a realistic assumption of plant uptake, the
nitrogen concentrations in groundwater are likely to be a fraction
of the above value that is based on conservative assumptions.
In summary, given the size of the proposed development, its
location within the watershed, the minimal amount of lot
disturbance as presented on the site plan and the results of the
nutrient loading analyses discussed above, I would not anticipate
any adverse effect on the water quality of Lake Cochichewick as a
result of the proposed project. With respect to soil erosion
measures, I find that the proposed hay bale/silt fence barrier
should be more than adequate given the amount of disturbed area
proposed, provided the barrier is installed properly and maintained
until vegetation is re-established.
NORMAN®EAU ASSOCIATES
i page 4
REFERENCES
IEP, Inc. 1987 . Lake Cochichewick Watershed Plan. Final Report.
North Andover, Massachusetts.
Morton, T.G. , A.J. Gold, W.M Sullivan. 1988 . Influence of
Overwatering and Fertilization on Nitrogen Losses from Home
Lawns. Journal of Environmental Quality, Vol. 17, No. l.
Starr, J.L. and H.C. DeRoo. 1981. The Fate of Nitrogen Fertilizer
Apllied to Turfgrass. Crop Science, Vol. 21.
U. S. Soil Conservation Service. 1981. Soil Survey of Essex County,
Massachusetts, Northern Part.
If you have any questions, please do not hesitate to call me.
Sincerely,
NORMANDEAU ASSOCIATES
William R. Arcieri
Senior Water Quality
Scientist
cc: Steve Stapinski, Merrimack Engineering
Town of North Andover f NORTH 9
. OFFICE OF 3?Ott�co 'c ca�OL
COMMUNITY DEVELOPMENT AND SERVICES A
146 Main Street 9
KENNETH R.MAHONY North Andover,Massachusetts 01845 S SAC AC H �5
9ACNUS�S
Director (508) 688-9533
November 20, 1995
Mr. James Colantonio
Coler & Colantonio
101 Accord Park Drive
Suite One
Norwell, MA 02061
Re: Lot 1 Dale Street
Dear Mr. Colantonio,
As per our discussion this afternoon I am sending you a copy of the
application, plan, and watershed report concerning Lot 1 Dale
Street. I have also enclosed a copy of the current Watershed
Protection District rict Bylaw.
As you will see from the application, there is a legal issue
concerning the appropriate bylaw. The lot was created in 1985
therefore the applicant is asserting that the 1985 bylaw applies.
We are asserting that the 1995 bylaw applies. I have sent this
issue out to our town counsel for a resolution. Therefore, please
hold off on the actual review of the project until this issue is
resolved.
However, I would like your opinion as to whether your firm is
qualified to conduct this type of review. The current Bylaw
requires:
1. Written certification from a registered professional engineer
(or other person trained in hydrogeology) that the project not
cause any significant degradation of the quality of quantity
of water in or entering Lake Cochichewick.
2 . Proof that there is no reasonable alternative location outside
the non-disturbance zone.
3 . Evidence that all on-site operations including but not limited
to construction, waste water disposal, fertilizer applications
and septic systems will not create concentrations of Nitrogen
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Julie Parrino D.Robert Nicetta Michael Howard Sandra Starr Kathleen Bradley Colwell
Town of North Andover o� AORoT"�ti
OFFICE OF �? y°`
COMMUNITY DEVELOPMENT AND SERVICES ° . A
146 Main Street
-1 Q41Tf0''p �y
KENNETH R.MAHONY North Andover, Massachusetts 01845 "SSACHust`
Director (508) 688-9533
Fax Transmittal Sheet
To:
Fax #
From: Kathleen Bradley Colwell, Town Planner
Date: J mi Ya/ %co. yA
Re: L®; 1
U U -
or
®
Total number of pages (including cover sheet)
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Julie Parrino D.Robert Nicetta Michael Howard Sandra Starr Kathleen Bradley Colwell
U
COLANTONIOZ
ENGINEERS AND SCIENTISTS
February 19, 1996 11
s
r it v
Ms. Kathleen Colwell �I � FBI Ill'
Town of North Andover -
146 Main Street
North Andover,MA 01845
RE: Engineering Review
Lot 1 Dale Street
Special Permit
Dear Ms. Colwell:
As requested, Coler & Colantonio, Inc. has reviewed the submittal prepared by Merrimack
Engineering Services. The Application is not dated, however the plans are dated April 12, 1995.
It is our understanding that the purpose of this review is to evaluate the Application for
conformance with the requirements of the Watershed Protection District as they relate to a
Special Permit Application for a lot created prior to 1994. It is our further understanding that the
Bylaws dated"Final 10/13/94"are the governing regulations.
We offer the following comments:
1. The parcel lies within the Watershed Protection District. The site is a 43,874 square foot
parcel of land on the southeasterly side of Dale Street. Wetlands flank both sides of the site.
2. The proposed limit of work is within 37.5 feet of wetlands along the west side of the site and
43 feet on the easterly side. The Bylaw requires a setback of 100 feet as a non-disturbance
zone.
3) The limits of the "Non-Disturbance" zone are not indicated on the plan as required in the
` , Bylaw. The entire locus lies within the"Non-Discharge"zone.
4. A report addressing the impact of site development on water quality in Lake Cochichewick
was prepared by Normandeau Associates. If the Board is not familiar with the
typequalifications of work„�Quld be pro vdedcratThe�analys sntpresented qualifications
eason reasonable the
individual site except as noted below. The Planning Board should also consider the
i"i � iti .. y quality
...,,. . i . .. �p . We
incremental degradation of water ualit in the lake due to other similar projects.,
question the assumption that onl 3700 s ure feet of the site will be landsca ed area,,, The
plan indicates a zone of approximately 10 to 15 feet around the building and driveway as
the limit of work. This will be difficult to enforce after construction and provides very
limited construction
work space. It is likely that a future homeowner.would wish to expand
” stated A restriction on the deed limiting the developed portion of the lot
to the area stad should
the yard, area to the lot.,be required as part of.any,approval.
'10'1 Accord Park Drive, Suite One 617-982-5400
Norwell, MA 02061-1685 Fax: 617-982-5490
5. The elevation of the cellar floor in the proposed building is below the elevation of wetland
areas on site. It is likely that groundwater lj.be,ericountered in the excavation for the
cellar and will be a problem relative to infiltration of groundwater into the cellar.
Typically, this would be controlled through the use of a sump pump. The regulations
require that designs recharge runoff to the extent feasible if a sump pump is used this
_m w
would have the effect of pumping groundwater to a surface discharge point. We
recommend that a test pit be excavated and observed by a certified soil evaluator to
estimate the maximum seasonal high groundwater table. The proposed cellar floor
elevation should be a minimum of one foot above this elevation.
6. The plans indicate a grass Swale which would collect runoff along the easterly side of the
building for discharge across the driveway to Dale Street. It also appears that a small
depression on the easterly side of the proposed driveway, in the Dale Street layout would
be created. We do not recommend creating a trap for water in the layout of a public_street.
The proposed swa el——w—oufd-discharge to an _e isting zditch along Dale Street. The
`regulations require that site runoff from impervious areas be .recharged__to the extent
feasible. The proposed Swale does not address this requirement Based on the report by
go--r ndeau Associates, soils on the site should be suitable for on sh' recharge.
C7) It does not appear possible to grade to the limits shown on the plan along the westerly side of
the driveway in the vicinity of the proposed 196 and existing 198 contours.
We appreciate the opportunity to assist the Planning Board on this project and hope that this
information is sufficient for your needs. If you have any questions please do not hesitate to
contact us.
Very truly yours,
COLER& COLANTONIO, INC.
C
John C. Chessia,P.E.
xc Merrimack Engineering Services
COLANTONIOZ
ENGINEERS AND SCIENTISTS
January 10, 1996
Planning Board
c/o Ms. Kathleen Bradley Colwell °
Town Planner
Town of North Andover
120 Main Street
North Andover,MA 01845
RE: Engineering Review
Lot 1 Dale Street
Proposal No. 1-516
Dear Ms. Colwell:
Coler & Colantonio, Inc. is pleased to provide you with this proposal to perform
engineering services associated with the above project. It is our understanding that we
are to review the plans and calculations for the above referenced single family house lot
in the Town of North Andover. Specifically, our review would issues associated with the
Special Permit filing under the Watershed Protection District Bylaw. The plans would
also be reviewed for conformance to standard engineering design practices.
Included in this proposal is a Scope of Services which outlines the specific tasks to be
performed, a listing of Additional Services which are excluded from this contract, and
discussions of Schedule,Fee and Basis of Payment.
1.0 SCOPE OF SERVICES
1.1 Review the plans and calculations for conformance with the requirements
of the Watershed Protection District Bylaw as well as standard engineering
practice.
1.2 Visit the property to observe existing conditions on the site.
1.3 Prepare a letter report commenting on the plans and calculations.
101 Accord Park Drive, Suite One 617-982-5400
Norwell, MA 02061-1685 Fax: 617-982-5490
2.0 ADDITIONAL SERVICES
Coler& Colantonio,Inc. would be pleased to provide the following additional services, if
required or desired, for mutually agreed upon additional compensation. Such additional
services would involve fees in addition to what is indicated in Section 4.0 of this
proposal. Attached is a Fee Schedule which will be used to establish billings for services
not specifically covered by this contract.
2.1 Attendance at meetings.
2.2 Additional review or preparation of additional reports.
2.3 Additional field visits.
3.0 SCHEDULE
Coler & Colantonio, Inc. will commence work upon receipt of written authorization to
proceed. Typically one to two weeks are required to perform the tasks listed in the Scope
of Services.
4.0 FEE
The fee to perform the services listed in the Scope of Services would be $1500 for the
information in hand. This is a not to exceed fee for the tasks listed in the Scope. You
will be billed based on actual hours worked on the project. Fees for services listed under
Additional Services, if required, would be billed on a time and materials basis in
accordance with the attached Fee Schedule.
The fees described above do not include expenses. Expenses such as mileage,
reprographic costs, etc. would be billed at cost plus a fifteen percent (155%) administrative
charge.
5.0 BASIS FOR PAYMENT
Invoices for services will be submitted monthly. By the signing of this proposal, it is
agreed and understood that payment will be made upon receipt of the invoice. The
owner/client agrees to limit the liability of Coler & Colantonio Inc. to the owner/client
and to all construction contractors and subcontractors on the project arising from Coler &
Colantonio, Inc.`s negligent acts, errors or omissions such that the total aggregate liability
of Coler& Colantonio, Inc., will not exceed the contract amount. It is further understood
that any balances on this account remaining unpaid for a period of 30 days will incur a
service charge of 1-1/2% per month (expressed as an annual percentage rate, the charge is
18%). It is further agreed that if said account is turned over for collection, reasonable
attorney's fees and costs of collection shall be added to the unpaid balances, whether or
not legal action is instituted. Coler & Colantonio, Inc. reserves the right to stop work on
the project if invoices are not paid within 30 days of the date of the invoice.
Prior to doing any work on the property, we reserve the right to post a notice of contract.
The parties to this contract specifically agree that Coler & Colantonio, Inc. has no
obligation to release drawings or other documents until the final bill for services has been
paid.
By signing this letter, you indicate your acceptance of the terms and conditions contained
herein and you will give us authorization to proceed with the scope of work indicated.
Sincerely,
COLER& COLANTONIO, INC.
C4
John C. Chessia, P.E.
Approved By: Agreed to and Accepted
for Basis of Payment By:
James J. Colantonio, Pres.
Date: Date:
COLER& COLANTONIO,INC.
FEE SCHEDULE
November 6, 1995
POSITION BILLING RATE
Principal Engineer and Surveyor $ 120/hr.
Division Manager $ 65 - 105/hr.
Professional Engineer/
Professional Land Surveyor $ 60 - 80/hr.
Project Manager $ 55 - 70/hr.
Level 1 Engineer Scientist and Surveyor $ 50 - 65/hr.
Level 2 Engineer Scientist and Surveyor $ 40 - 55/hr.
Level 3 Engineer Scientist and Surveyor $ 35 - 40/hr.
Draftsperson $ 35 - 45/hr.
Technician $ 25 - 40/hr.
Support Staff $ 25 - 40/hr.
FIELD SURVEY
Two -person field crew and equipment $ 75 - 100/hr.
TOWN OF NORTH ANDOVER, MASSACHUSETTS
OFFICE OF
CONSERVATION COMMISSION
10RTN 9
�°` Ee °`° 0 TELEPHONE 683-7105
a ,-..g:.,y ,. A
��SSAGHU
DATE: December 10, 1985
TO : Planning Board
FROM: Willie Vicens, Chairman
SUBJ: Coventry Estates
The NA CC visited the project site several weeks ago, held, a public hearing on
the Notice of Intent for this project on Wednesday December 4th and Tracy Peter
visited the site again. on Thursday December 5th, Based on these site visits and
public hearing we have determined that some additional information is required
before we can issue an Order of Conditions. Copies our letters to the applicant
have bden sent to you.
Overall we have the following comments on this project:
1. Watershed District: The portion of the site fronting on Dale Street lies in
the watershed district. It is likely. that we would,impose conditions to re-
el
strict development within 100 feet of the wetlands on Lots l through 5. Such
restrictions may make these lots unbuildable.
Extent of Wetlands: We believe the wetlands on the site are more extensive
than shown on the plans dated November 8, 1985. Specifically, there are
wetlands on Lots 72 through 16, and Lots 31 and 32.
3. Runoff Control: The current project does not include runoff control measures
or the portion of the property draining to South Bradford Street. This is
unacceptable to the NACC and provisions must be made for on-site or off-site
runoff control.
4. Steep Slopes: Some of the lots will have very steep slopes. Both temporary
erosion control during construction and permanent stabilization after completion
should,be provided in these lots (e.g. , 17 through 30) .
We hope these comments are of help.
1�@ L9 0 Y
l
DEC 1 01985
PLANNING BOARD
Principal Points upon which Application is Based
This lot was created in 1985 as part of the Coventry
subdivision. A preliminary subdivision plan was filed
The definitive subdivision plan was approved by the
Planning Board on December 16, 1985 . The Planning Board endorsed
the plan on MBW04N 2 y ► 1986
The property was subject of litigation with the North
Andover Conservation Commission which began in May, 1991 . The
litigation concluded in Essex Superior Court in May, 1995 . The
I
Conservation Commission's appeal of a Superseding Order of
i
Conditions issued by the Department of Environmental Protection
(DEP) is pending, but the issue is expected to be resolved along
the same terms as that of the Superior Court litigation.
The lot is subject to the provisions of the zoning bylaw in I
i
_Zfect when the preliminary subdivision plan was submitted. The
eight-year zoning freeze provided by MGL c. 40A s . 6 , and MGL
c.41 s. 81Q, is extended by the period of any litigation
involving the right to develop the property.
Under the zoning bylaw in effect in 1984 , no construction is
to take place within one hundred ( 100) feet horizontally from the
edge of tributaries of Lake Cochichewick except by special
s
permit.
The applicant believes that the current plan meets the j
conditions for a special permit listed in Section 10 . 31, par. 1,
Items a. through e. , of the 1984 bylaw. Specifically, the
single-family home proposed for the site is :
a. An appropriate location for the residential use proposed;
b. Will not adversely affect the neighborhood;
c . Will not be a nuisance or serious hazard to vehicles or
pedestrians .
Further,
d. Adequate and appropriate facilities will be provided for
the proper operation of the proposed use, viz. , the dwelling will
be connected to town water and the site is sewered; and
I
e. The proposed single-family dwelling is in harmony with
the general purpose and intent of the bylaw.
Enclosed with this application is a Water Quality and
Quantity Evaluation report from William R. Arcieri, Senior Water
Quality Scientist of Normandeau Associates . He concludes in the
report that there will not be " . . .any adverse effect on the water
tality of Lake Cochichewick as a result of the finished
project. "
The primary water quality concerns associated with this
project relate to nutrients, particularly phosphorus and
nitrogen, potentially contributed from various sources . Mr.
Arcieri's report contains a detailed explanation of how each of
these added nutrients will be handled.
Further, under the North Andover Conservation Commission's
Order of Conditions , soil erosion measures, including the
required hay bale/silt fence barrier should be more than
adequate, given the reduced amount of disturbed area.
I
i
An earlier application to the Planning Board for a special
Pf
3rmit contemplated a house with a footprint, seventy ( 70) feet
wide by thirty-four (34 ) feet deep. The house was oriented across
the lot, reaching toward each of the wetlands .
The current proposal--which has been approved by the
Conservation Commission --is for a structure with far less
impact. It calls for a footprint only thirty-two ( 32) feet wide
by fifty-nine (59 ) feet deep.
Other lots in Coventry have obtained special permits for the
construction of single family homes within one hundred ( 100 ) feet
of a lake tributary. [See special permits granted for Lots 2A
and Lot 3A]
Moreover, at least twenty-six (26) special permits for
construction of single family dwellings within 100 feet of a
tributary of Lake Cochichewick or a wetland in the Watershed
Protection District have been granted by the Planning Board from
1982 to the present, many substantially closer to the lake or a
major tributary.
G208032
Article 10. IMPLEMENTING COLLECTIVE BARGAINING AGREEMENTS. To
be see
exif the
Town will vote to raise and appropriate the sum of $
under the direction of the Board of Selectmen for the purpose of implementing
collective bargaining agreements reached with Town contractual employees.
(Petition of the Selectmen) VOTED to approve the article in the amount of
$82,950.
WATERSHED DISTRICT PRESERVATION ARTICLES (11-15)
Article 11. COMPREHENSIVE PLANNING STUDIES FOR WATERSHED DISTRICT. To
see if the Town will vote to raise and appropriate or take from available funds
the sum of $ 75 ,438 to be expended under the direction of the Board of
Selectmen for the purpose of undertaking certain comprehensive planning studies
in connection with the preservation of Lake Cochichewick and the public
drinking water VOTED to approve the sown of North
written.Andover. (Petition of the
Selectmen) PP
Article 12. WATERSHED DISTRICT TEMPORARY GROWTH LIMITATION. To see if
the Town will vote to amend Section
follows Watershed District, of the Zoning
Bylaw, by adding a paragraph (4) , as
" (4) Lake Cochichewick Preservation Amendment
a) Notwithstanding anything contained in this bylaw to the
contrary, no permits shall be issued for the
construction of any new building, structure, road, or
driveway or for earth removal, except for the proposed
municipal water filtration plant, within the Watershed
District for a period of three (3) years from the
effective date of this amendment.
b) This amendment shall not apply to any renovation,
alteration, or addition to an existing u bu ,
ild ing
structure, road, driveway, or any
agricultural or horticultural use.
c) A use variance may be granted by the Board of Appeals
for the issuance of a building permit within this
three-year period but not for a use not otherwise
allowed by the district regulations.
(Petition of the Selectmen)
EXPLANATION: This amendment provides for a three-year prohibition on the
issuance of building permits and special permits in the Watershed District, to
provide controlled development in the Watershed District while the appropriate
Town boards, commissions, and officers conduct and implement a comprehensive
planning study, pursuant to the terms of the previous warrant article, relative
to the preservation of Lake Cochichewick, our source of water supply;
recognizing that a proposed water filtration plant for the Town's public
drinking water supply is not expected to be completed until 1988 . Exempted by
General Laws from the provisions of this amendment followed by lots
a sdown in a
definitive subdivision plan, or a preliminary plan
plan within seven (7) months, submitted to the Planning Board and written
notice of which is given to the Town Clerk prior to the date on which this
amendment is voted upon at Town Meeting. Also exempt by the General Laws from
the provisions of this amendment are lots shown ondefinitvetosubdi isi noflans
endorsed by the Planning Board within eight (8) years prior the
vote of Town Meeting on this amendment; and lots shown on Form A plans,
so-called, so endorsed within three (3 ) years prior to the date of said vote. "
VOTED to approve the article as written (by a unanimous vote) .
111
COLER &
COLANTONIO Z
ENGINEERS
FACSIMILE COVER SHEET
To: Heidi Griffin
Company: Planning Board
Phone: 978-688-9535
Fax: 978-688-9542
From: Jason Loiselle
Company: Coler & Colantonio, Inc.
Phone: 781-982-5400
Fax: 781-982-5490
Date: October 15, 1999
Pages including this
cover page: 1
Comments:
Heidi,
We have reviewed the submitted "Water Quality Evaluation"for Lot#1 Dale Street performed by
Wetland Preservation Inc. dated October 5, 1999 for conformance with the Town's Watershed Protection
District Bylaws. This study indicates no significant impact to the Water Quality of Lake Cochichewick.
Reportedly, the proposed nitrogen loading will be 1/10 the required minimum drinking water standard
and the proposed phosphorous loading will cause a 0.05% increase in the loading. The loadings, as
reported, were modeled using the development of the entire lot and are thus conservative in their results.
If you have any questions, please call me 781-982-5434.
Jason
XC: Jim Rand (978) 688-9573
Merrimack Engineering (978)475-1448
U
COLANTONIOZ
ENGINEERS AND SCIENTISTS
July 15, 1999
Heidi Griffin
Planning Board
27 Charles Street
North Andover, MA 01845
RE: Supplemental Engineering Review
Lot 1 Dale Street
Special Permit
Dear Ms. Griffin:
In response to your request, Coler & Colantonio, Inc., has reviewed the requirements for the
Watershed District Special Permit for the above referenced project. Plans have been reviewed for
conformance under these submittal requirements and standard engineering practice. The
submittal package included the following information:
Plan Entitled:
• "Site Plan of Land in North Andover, Mass " one sheet dated June 29, 1999.
Prepared by Merrimack Engineering. Received July 12, 1999.
• Response letter and test pit information dated July 9, 1999. Prepared by Merrimack
Engineering. Received July 12, 1999.
The following comments are supplemental to our original review letter dated February 19, 1996.
A copy of this letter is attached.
1. No further comment.
2. No further comment.
3. No further comment.
4. No further comment.
5. Test pits logs have been provided.The logs submitted indicate the cellar floor to be
constructed approximately 0.5-feet below the high groundwater elevation. In addition, the
proposed roof recharge infiltrators will provide 1.5-feet of separation from groundwater. It is
recommended that a separation of 2-feet of groundwater separation be provided for
groundwater infiltration.
6. The proposed swale on the eastern side of the driveway will drain into the roadway or will
accumulate at the street line.
7. The contours on the westerly side of the driveway have been satisfactorily modified.
101 Accord Park Drive 781-982-5400
Norwell, MA 00061-1685 Fax: 781-982-5490
We appreciate the opportunity to assist the Planning Board on this project and hope that this
information is sufficient for your needs. If you have any questions please do not hesitate to
contact us.
Very truly yours,
COLER & COLANTONIO, INC.
C av'�1�4
Yhn JC. Chessia,P.E.
xc: Merrimack Engineering, Inc.
Jim Rand,DPW
Coler ♦ • • •
FcApix
To: Heidi Griffin From: John Chessia
Fax: 978-688-9542 Pages: 3
Phone: 978-688-9530 Date: 07/15/99
Re: Supplemental Engineering Review XC: Jim Rand 978-688-9573
Merrimack Engineering, Inc.978-475-1448
❑ Urgent Q For Review ❑Please Comment ❑ Please Reply ❑ Please Recycle
LAW OFFICES
127 TURNPIKE STREET
NORTH ANDOVER, MASSACHUSETTS 01845-5095
VICTOR L. HATEM (978) 685-3368
ALSO ADMITTED IN N.H. _9Q ulp FAX: (978) 682-1712
JOSEPH V. MAHONEY
PETER L. HATEM
ALSO ADMITTED IN FLORIDA AND N.H.
JOHN E. MAHONEY
July 9, 1999 _ --
John C. Chessia, P.E. + J U L '1 2 1999
Coler& Colantonio, Inc. U U L 4 1999
101 Accord Park Drive, Suite One
Norwell, Massachusetts 02061-1685
Re: 475 Dale Street
Special Permit
Dear Mr. Chessia:
Enclosed please find a Rooftop Leaching System Design, Soil Suitability Assessment for
On-site Sewage Disposal and two Site Plans of Land for the above referenced property.
Should you have any questions, please contact me.
Very truly yours,
Peter L. Hatem
PLH/bld
Enclosures
H:\G2080\Ltr to John Chessia 7-9-99.doc
1
FORM 11 - SOIL EVALUATOR FORN1
Page 1
Commonwealth of Massachusetts
Isom A►.iDorez , Massachusetts
' foil Suitability Assessment for On-site Sewage Disno al
STo2f✓1wrt � I—i Gt-t.t . 001,Y
C.�S Gro1�i►�
Performed By: ...................... ...............................
.............. .......................................
Witnessed By: ......................... ...........................
l cation Address or Address,ud Art`I- � ATr-"
L- `T"�.� ( "r L . I LI—7 C45V ( rekph= I I Z7 -rW*.�A rS sT-
DAI�G S'l t:T ►,1D• A Cb�IE,(Z�1-1A•Ol$�{S
u3. 674 s.F.
New construction ❑ Repair ❑
Office Review
Published Soil Survey Available: No ❑ Yes
Year Published ..�.�g�.. Publication Scale 1. .ISgyd Soil Map Unit .. �-�
DrainageClass WD..... Soil Limitations ............................................................................................................._
Surficial Geologic Report Available: No ❑ Yes ❑
Year Published .. -- Publication Scale
GeologicMaterial (Map Unit) ......:............................................................................................................................
Landform ................. ............................................................................................................................
..........
Flood Insurance Rate Map: 2SbOg8 000 Clo-2-�t 3
Above 500 year flood boundary No ❑ Yes
Within 500 year flood boundary No ❑ Yes ❑
Within 100 year flood boundary No ❑ Yes ❑
Wetland Area: o
National Wetland Inventory Map (map unit) .........f.>...�........�..tT�....�.�r-�-t��9�[-.�-1................
Wetlands Conservancy Program Map (map unit)
..........................................................................
Current Water Resource Conditions (USGS): Month MA
Range : Above Normal �
❑ ormal Below Normal El I�S�vt�GJ�
Other References Reviewed: V5, 6 ,5- l✓IAPS
FOphj II - SOIL EVALUATOR FORM
Page 2
Ors-site Review
Deep Hole Number ........ Date: Time: weather �o........ Y'
............................
Z.......FIA..................................................................................I.............................
Location (identify on site plan) S .—
Land Use ....................... Slope (oAl ....10...... Surface Stones .... Y...............................I.......................
....................................................................
VegetationPAAC-L... ....................................................................................................
Landform ................I.........................1-..............
position on landscape (sketch.on the back) •••••....•••................................................................
Distances from: Drainage way feet
Open Water Body feet
Possible Wet Area feet Property Line .........•••.••••-• feet
Drinking Water Well feet Other ................................
il Texture Soil Color Soil Mottling Other
So
Depth from Surface Soil Horizon (Munsaill (Struure,ct Stones,Boulders,
(Inches)
(USDA) Consistency, %Gravel)
zo^ 6FAV,
ze - loo, G 6FAV. S-1— I D\4 V-5/ 7,S-f(zVf3 too 9� —N-- V,
&12-
qz" poege-j-jc, of 3A.WD,
Parent Material (geologic) ..... ................................................... Depth to Bedrock:
aeSIhAo- Groundwater: Standing Water in the Hole: Weeping from Pit Face: ......
Estimated Seasonal High Ground Water: qz"..
Komi It - SOIL EVALUATOR FORM
Page 2
'
Deep Hole Number ... ..........••• Time, Weather ..... �4y
Location (identify on site plant SE!E.........N.................I...........................................................................................................................
Land Use .................... Slope (%I ...... Surface Stones ..... ............................... ...............
Vegetation . ..............................................................................................................
Landform .......................I..........................................
. . ... ...............................................................................................................
position on landscape (sketch.on the back► ...... ... ................ I.
Distances from:
Open Water Body feat Drainage way....S: ••.• feet
Possible Wet Area ... feet Property Una ................... feet
Drinking Water Well ...... ... feet Other .........................................
I F T
DEEP OB N ROME DG
Soil Texture Soil Color Soil Mottling Other
Depth from Surface Soil Horizon (USDA) Imunselli (Structure,Stones,SoLdoers,
(Inched Consistency, %(travel)
10 A
toc>
35."-60 H � Vr-
&-
6FAV t. S C)�3 t 10TT14D
A >1G. S KG
Parent Material (geologic) ..... TI LL.......................................................... Depth to Bedrock:qq
pnpLh Gr ....... Weeping from Pit Face:
_jo_ 2gadwiLer, Standing Water in the Hole:
Estimated Seasonal High Ground Water:
FORM 11 - SOIL EVALUATOR FORM
Page 3
Determination for Seasonal High Water Table
Method Used:
❑ Depth observed standing in observation hole................... inches
❑ Depth weeping from side of observation hole .......... inches
9 Depth to soil mottlesQZ.,.YZ inches
❑ Ground water adjustment .......... feet
Index Well Number ................... Reading Date ...- Index well level
Adjustment factor �. Adjusted ground water level .............................:
.........................
Depth of Naturally Occurring Pervious Material
TW0 ervious material exist in all areas
Does at least4ww feet of naturally occurring p
observed throughout the area proposed for the`soil absorption system?
If not, what is the depth of naturally occurring pervious material?
Certification
certify that on (date) I have passed the examination approved by the
Department of Environmental Protection and that the above analysis was
performed by me consistent with the required training, expertise and experience
described in 310 CMR 15.017.
Signature Z� 5V �—� Date -2`t-
FORM 12 - PERCOLATION TEST
COMMONWEALTH OF MASSACHUSETTS
1 10V� A 3...cOavGtG Massachusetts
Percolation Test
S-2o- Time: �`1...................
Observation Hole # I P 2
Depth of Perc
F-Z
� '+ I-7 ' . 14� „
Start Pre-soak
End Pre-soak 1 : Z-1
2
Time at 12 � , 2-7
Time at 9" 2
Time at 6" 2; p
Time (9.._6.,) 23 O
Rate Min./Inch %2 Mi�j �►I�
Site Passed Site Failed ❑
Performed By: U
Witnessed By:
Comments:
0
C®Lr/_\NT N1 Z
ENGINEERS ANO SCIENTISTS
February 19, 1996
Ms. Kathleen Colwell
Town of North Andover
146 Main Street
North Andover, MA 01845
RE: Engineering Review
Lot 1 Dale Street
Special Permit
Dear Ms. Colwell:
As requested, Coler & Colantonio, Inc. has reviewed the submittal Mer i ack
Engineering Services. The Application is not dated, howev er p lans are dated April
It is our understanding that the purpose of this review is to evaluate the Application for
to a
conformance with the requirements of the Watershed Protection our further understanding as they relate
that the
Special Permit Application for a lot created prior to 199
Bylaws dated"Final 10/13/94" are the governing regulations.
We offer the following comments:
I. The parcel lies within the Watershed Protection District• d of the s foes
of land on the southeasterly side of Dale Street. We tlands flank both s and
2. The proposed limit of work is within 37.5 feet of wetlands along the
feet as a side
o of the site
ban e
43 feet on the easterly side. The Bylaw requires a setback of
zone.
3. The limits of the "Non-Disturbance" zone are not indicated on the plan as required in the
Bylaw. The entire locus lies within the Non-Discharge"zone.
4. A report addressing the impact of site development on water d quality in Lfa e ochichewick
e the
was prepared by Normandeau Associates. If the Board
qualifications of Normandeau Associates a statement of their qualiica ions o pe eofo this
type of work should be provided. The analysis presented a pp e the
individual site except as noted below. The Planning Board should also consider the
incremental degradation of water quality in the lake due to other similar projects. We
question the assumption that only 3700 square feet of the site will be landscaped area. The
plan indicates a zone of approximately 10 to 15 feet around the building and driveway as
the limit of work. This will be difficult to enforce after construction and provides very
limited construction work space. It is likely that a future homeowner would wish to expand
the yard area on the lot. A restriction on the deed limiting the developed portion of the lot
to the area stated should be required as part of any approva l
101 Accord Park Drive, Suite One 617-982-5400
17 a17-9R?-5490
5. The elevation of the cellar floor in the propoWle encountered dbbluntbelow
in thelexcavat on for wetland the
areas on site. It is likely that groundwater
cellar and will be a problem relative to infiltration of groundwater The the cellar.
Typically, this would be controlled through the use of a sump Pump. um is used this
require that designs recharge runoff to feasible
surfaces discharge point. We
would have the effect of pumping groundwater to
recommend that a test pit be excavated observed by certified evaluator
estimate the maximum seasonal hg h groundwater table. The proposed cellar floor
elevation should be a minimum of one foot above this elevation.
6. The plans indicate a grass swale which would cDaect runoff alt na also appears that a small
building for discharge across the driveway
depression on the easterly side of the proposed driveway, rnnhhellayoutt of apublic street.
be created. We do not recommend creating p
The
The proposed swale would discharge to � xisting re totrthe extent
regulations require that site runoff from p evious areas
feasible. The proposed Swale does not address beis requirement.
.Be sed on the report by
Normandeau Associates, soils on the site should
7.
It does not appear possible to grade to the limits shown on the plan g she westerly side of
the driveway in the vicinity of the proposed 196 and existing 19 conto
We appreciate the opportunity to assist the Planning Board on i project and hope that this do not hesitate to
information is sufficient for your needs. If you have any que st p
contact us.
Very truly yours,
COLER& COLANTONIO, INC.
C
John C. Chessia,P.E.
xc Merrimack Engineering Services
COLER
COLANTONIO Z
ENGINEERS nND SCIENTISTS
February 19, 1996
Ms. Kathleen Colwell
Town of North Andover
146 Main Street
North Andover,MA 01845
RE: Engineering Review
Lot 1 Dale Street
Special Permit
Dear Ms.Colwell:
As requested, Coler & Colantonio, Inc. has reviewed the submittal prepared by
Merrimack
Engineering Services. The Application is not dated, however the plans are dated April 12, 1995.
It is our understanding that the purpose of this review is to evaluate the Application for
conformance with the requirements for a lot created prior to 994P It isconr furtheccunderstand understanding that the
Special Permit Application
Bylaws dated"Final 10/13/94" are the governing regulations.
We offer the following comments:
1. The parcel lies within the Watershed Protection
Street. Wetlands flank both sides of the sit of
parcel of land on the southeasterly side o f Dale
2. The proposed limit of work is within 37.5 feet of wetlands along the west side of the site and
43 feet on the easterly side. The Bylaw requires a setback of 100 feet as a non-disturbance
zone.
3. The limits of the "Non-Disturbance" zone are not indicated on the plan as required in the
Bylaw. The entire locus lies within the"Non-Discharge"zone.
4. A report addressing the impact of site development If the Board quality in Lake Co hwith ewthe
was prepared by Normandeau Associates dorm this
qualifications of Normandeau Associates a statement of their qualification amble for the
type of work should be provided. The analysis presented appears
individual site except as noted below. The Planning Board should also consider the
incremental degradation of water quality in the lake due to other similar projects. We
question the assumption that only 3700 square feet of the site will be landscaped area.
driveway plan indicates a zone of approximately 10 to 15 feet around the building and y
the limit of work. This will be difficult to enforce after construction and provides very
limited construction work space. it is Iikel�that�futmiting the�developcd would
portiontof the to
the yard area on the lot. A restriction on
art of any approval.
to the area stated should be required as p
,n, nrrnrd Park Drive.Suite One 617-982-5400
Project 1330 Atty. Peter Hatem-North Andover,Massachusetts
Rooftop Leaching System Design
This report provides calculations demonstrating that the proposed rooftop leaching systems satisfy the requirements of DEP's
Storm Water Management Standards.
Storm Water Quality Pre-Treatment and Volume of Treatment Standards
Runoff from residential rooftops is to be considered uncontaminated per Storm Water Management Standard No. 1.
Thus, there is no requirement for pretreatment or volume of treatment.
Storm Water Quality Volume of Infrftration Standard
The project soils are predominately hydrologic group B(Canton CaB and CaQ.Thus,a depth of 0.25 inches over the
project's impervious area(2,878 sq.ft rooftop and driveway)will be used;
(2,878 sq.ft)(0.25 inches)/(12 inches/foot)=60 cu.ft
Check Available Inflow Volume from Rooftop
Using the 2 year-24 hour runoff depth of 3.1 inches,and a CN value of 98 for rooftop, the depth of runoff equals 2.9
inches per SCS TR55 Figure 2-1. The available volume of runoff from a the proposed rooftop(1,612 sq.ft)equals;
(1,612 sq.ft)(2.9 inches)/(12-incheslfoot)=389 cu.ft
Check Dead Storage of Proposed System
Use 20 Infiltrator high capacity chambers(or equivalent)placed in a 7 foot wide by 64.5 foot long trench filled with
double washed crushed stone to a depth of 16 inches. Approximate stone void ratio as 0.33 of total;
Total System Volume=(64.5 ft long)(7 ft wide)(16/12 ft high)=602 cu.ft
Structure Volume=(20 units)(16.3 cu.ft)=326 cu.ft
Stone Void Volume=(602 cu.ft-326 cu.ft)(0.33 Vv/Vt)=92 cu.ft
Total Void Volume=326 cu.ft+92 cu.ft=418 cu.ft
JOi!i A. !\
cvm
lU No.39'367
:4
►►Y
Page 1
5. The elevation of the cellar floor in the proposed building is below the elevation of wetland
areas on site. It is likely that groundwater will be encountered in the excavation for the
cellar and will be a problem relative to infiltration of groundwater into the cellar.
Typically, this would be controlled through the use of a sump pump. The regulations
require that designs recharge runoff to the extent feasible, if a sump pump is used this
would have the effect of pumping groundwater to a surface discharge point. We
recommend that a test pit be excavated and observed by a certified soil evaluator to
estimate the maximum seasonal high groundwater table. The proposed cellar floor
elevation should be a minimum of one foot above this elevation.
6. The plans indicate a grass swale which would collect runoff along the easterly side of the
building for discharge across the driveway to Dale Street. it also appears that a small
depression on the easterly side of the proposed driveway, in the Dale Street layout would
be created. We do not recommend creating a trap for water in:,`= layout of a public street.
The proposed swale would discharge to an existing ditch along Dale Street. The
regulations require that site runoff from impervious areas be recharged to the extent
feasible. The proposed Swale does not address this requirement. Based on the report by
Normandeau Associates, soils on the site should be suitable for on-site recharge.
7. It does not appear possible to grade to the limits shown on the plan along the westerly side of
the driveway in the vicinity of the proposed 196 and existing 198 contours.
We appreciate the opportunity to assist the Planning Board on this project and hope that this
information is sufficient for your needs. If you have any questions please do not hesitate to
contact us.
Very truly yours,
COLER& COLANTONIO,INC.
John C C4�P.E.
xc Merrimack Engineering Services
7-17g6 RRC) RnG 'nan 'Won ..lanoDUW Ua.AO 1 H7 T :SZn as-an- i nr,
Town of North Andover NORTH
OFFICE OF
3�O""'ED . 4,
COMMUNITY DEVELOPMENT AND SERVICES ° : A
o
146 Main Street Qg1TF �y
KENNETH R.MAHONY North Andover,Massachusetts 01845 9SS4c"US�t
Director (508) 688-9533
November 20, 1995
Mr. James Colantonio
Coler & Colantonio
101 Accord Park Drive
Suite One
Norwell, MA 02061
Re: Lot 1 Dale Street
Dear Mr. Colantonio,
As per our discussion this afternoon I am sending you a copy of the
application, plan, and watershed report concerning Lot 1 Dale
Street. I have also enclosed a copy of the current Watershed
Protection District Bylaw.
As you will see from the application, there is a legal issue
concerning the appropriate bylaw. The lot was created in 1985
therefore the applicant is asserting that the 1985 bylaw applies.
We are asserting that the 1995 bylaw applies. I have sent this
issue out to our town counsel for a resolution. Therefore, please
hold off on the actual review of the project until this issue is
resolved.
However, I would like your opinion as to whether your firm is
qualified to conduct this type of review. The current Bylaw
requires:
1. Written certification from a registered professional engineer
(or other person trained in hydrogeology) that the project not
cause any significant degradation of the quality of quantity
of water in or entering Lake Cochichewick.
2 . Proof that there is no reasonable alternative location outside
the non-disturbance zone.
3 . Evidence that all on-site operations including but not limited
to construction, wastewater disposal, fertilizer applications
and septic systems will not create concentrations of Nitrogen
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Julie Parrino D.Robert Nicetta Michael Howard Sandra Starr Kathleen Bradley Colwell
in groundwater greater than the federal limit at the down-
gradient property boundary.
4 . Projections of down-gradient concentrations of nitrogen,
phosphorus and other relevant chemicals at property boundaries
and other locations deemed pertinent by the Planning Board.
Please let me know if your firm will be able to do this type of
review. I will let you know when the legal issues have been
resolved. If you have any questions please do not hesitate to call
me at (508) 688-9535.
Sincerely,
Kathleen Bradley Colwell
Town Planner
COLANTQNIO�_
--
Ei`dhIF.11=Er�18 AriO '�. EfAi"nc":"g
January 10, 1996
Planning Board
c/o Ms. Kathleen Bradley Colwell
Town Planner
Town of Ni onli Andover
120 Main `street
North Andover, ;V1A 01845
RE, Engineering Review
Lot 1 Dale Street
Proposal No. 1-516
Dear 1v1s, Colwell:
Coler & C'olantonio, Inc. is pleased to provide vc)u with this proposal to pffr0 on
engineering services associated with the above project, It is our uaderstandin., that we
are to review the plans and calculations for the at}ove referenced single family house llot
in the Town of North Andover. Specifically, Maur review would issues associated with the
Special Permit tiling under the Watershed Protection District Bvlaw. The plans would
also be reviewed for coni;orinance to standard engineering design practices.
Included in this proposal is a Scope of Services ll outlines the
Y omptliisicoi�trac:ttuax be
�
performed, a listing of Addittc5nal Services e w
discussions of`schedule, Fee and Basis of Payment.
t.tl SCOPE OF SERVICES
1.1 keview the plans and calculations for conformance with the requirements
of the Watershed Protection District Bylaw as well as standard-engineering
practice.
1,2 visit the property to observe existing conditions on the site.
Prepare a letter report coi}inzenting un tlAe plans and calculations,
1 Q Accord Park Drive, Suite Ono 617-982.5400