Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
81 ROOFTOP SOLAR PANELS 24.7 KW
re %40RTH 0.4Kg4eo BUILDING PElT 41 0 TOWN OF NORTH ANDOVER ° APPLICATION FOR PLAN EXAMINATION y PermitNO: Date Received "QAv@OwKr""�� Date Issued: " pSSOCHU`�� IMPORTANT: A221icant must com Tete all items on this page LOCATION 164 Pleasant St Print PROPERTY OWNEA Nlb2go Sorn�rado . Print MAP NO: PARCEL: ONINta DISTRICT: Historic District yesrcno Machine Ship Village yes TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family ❑Addition ❑Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic ❑Well ❑l Floodplain ❑Wetlands ❑ Watershed District ❑Water/Sewer Installation of a roof mounted solar array. Identification Please Type or Print Clearly) OWNER: Name: Alberto Sobrado Phone: 978.335.6536 Address: 164 Pleasant St North Andover MA 01845 CONTRACTOR Name:, = Phone: 60.3p4.5035 Twin State un Address: Oi) Supervisor's Canstruutian License; Exp, Date,: HomeImprovement License; Exp. Date: " / ARCHITECT/ENGINEER TLH Consulting LLC Phone:978.362.1804 Address: 505 Middlesex Turnpike Billerica MA 01821 Reg. No. 41433 FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ FEE: $ Check No.: Receipt No.: :25 NOTE: Persons contracting wi un egistered contractors do not have access tonu d Signature of Agent/Ow ��r - _ -�z*,-*;5�7 �ignature of contra r-1111111"I AM %AORTH it own ot Anc'lover 0 o . .. 2640 IL ��K� h ver, Mass, LAKE 0, BOARD OF HEALTH Food/Kitchen P E R11T T L U Septic System t THIS CERTIFIES THAT ...................... ... ......... ........ ...............14............................................................. BUILDING INSPECTOR . Foundation has permission to erect.......................... buildings on ...... ... ... �� . . ... ... ..... .... ............... Rough to be occupied as .. .. ....2MN%P...&wp....... .1. a ...� .................. Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMITIMONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTI TS Rough Service ................. . .. ...... ...................................:........ Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required t® Occupy Building Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approvedy the Building Inspector. Burner Street No. Smoke Det. TLH CONSULTING, LLC STRUCTURAL ENGINEERING SERVICES 505 Middlesex TPK Unit 14 Billerica, MA 01821 Phone— (978) 362-1804 Mobile — (978) 406-5726 July 6,2015 Brian Roy Big Sky Renewable Energy LLC 6 Green Street Hooksett,NH 03106 Re: Existing Roof Framing Analysis 170 Pleasant Street, North Andover,MA 01845 TLHC Project# 150702 Dear Brian: On July 2, 2015 TLH Consulting (TLHC) visited the site referenced above. The purpose of the visit was to observe the existing roof rafters in the area where the proposed solar array is planned to be located. This information was used to determine if the existing rafters have enough reserve capacity to support the new proposed solar array. TLHC performed a structural analysis of the existing roof framing members. The analysis was based on our measurements and observations, the 2009 International Building Code and the Massachusetts Amendment. In addition we used the proposed solar product data provided by Big Sky Renewable Energy LLC. The analysis was conducted on a single story commercial space with two wings. The existing roof rafters for the doctor's office wing are 2x4 wood members spaced at 24" on center; the waiting room wing are 2x6 wood members spaced at 20" on center. It is our opinion 1x6 wood members should be added to the waiting room wing connecting joists to increase stability. See the attached sketch for additional information Based on our review, a new solar array adds approximately 2.1 pounds per square foot (PSP) of additional load to the roof rafters on one side of the roof It is our opinion the existing roof rafters have enough reserve capacity to accommodate the additional loads associated with the new array. The loads we used for analysis were based on the 2009 International Building Code along with the Massachusetts Amendments. The code indicates the ground snow for North Andover, MA is 55 PS F and the wind velocity is I 10 miles per hour. This intbri-nation might be helpful for the array design. Thanks for the opportunity to provide our services to you. If you have any questions please feel free to call us at(978) 362-1804. Sincerely, VV Todd Hedly, P.E. cc: file �4�fy�rldt , eta Attachment. TIN CONSUITING srRuC,T uRAt.. ENGINEERING SERVICES Description of Calculation: Job No. Job Name, Date Calc'd by Scale of Sketch (if applicable): Chk'd by V 1w , , � r °w"ry , r I a. i I I , I n, ` ..�; I� i I I t r , II f I , I f r I I , I I , I I Y It I , I � i ' I :i 7 POWER PURCHASE AGREEMENT .« L site,rjsitdate:Tvin State Sun, LLC _ t �x z PO.Box 7855,New London,NH 03257 603-304-5035 'This Sales Agreement(the"Agreement")is madeday of BETWFEN:Twin State Stars,LLC(the"Seller" !i R i r`{'aLIStOt1ier, L11 a, _ � u ijj LIE}p J } f: }J nigh qual ty oert`sfied panels ,; p tring or micro iriderters. WI e;rai eo r sr grad cost in,=ieled in fhrs ofl�r° ' art}iut maeec r astgnd to yc�r praset ,r �lirfngand ele(jr c hardware tjuncti€ti boy,lightnigg,arrestga € a= i rrr; sh pp i g rid =s iiiducied,n this offer o Ant S'StEtT#. ;rte ? "Ut1Jy grade meterurnerti ri fps 2,1 Enn i ng erto?imufafion � lstem ron'i�trc, = 'Sife assessrne Af er sales semi e and#�Mur� �tirg haiitr anal js;s 6,1 Docunta+on /20-draiiring is provided#3t i�3tp ng per, i t bequest ��rrsEal)aiort of ttie sstlar i?�I par els. 3f3-dEsign iu prffiided;o aslstallt�or r ' l #res,#altatiiilt�+f ttte�'rtoui�sng,system - r r F j�� ',"`; ",' EtEGIiTG'sl-YdblltS iYi1,Ag,Cjlrflii2Cfipn Q# Il�pi� 1 .Y,GIuS's011S„ ", -„ s1,p ` �;�, ✓'n)`other senric�'thal;foes sok ap#sear to t3ifs�ntr�t � �r �,��A WE REE :,r= >., ��sistar�'through fir plias of dfe pToeess , r r ; 1iAAp�catiarr r 4 ' ' Y ' `; .. d�'4�/s� '�~��r°r�r'rr �l�r'���1:�:r�✓r, � rar�"s�,.ayrr•�r ���.� °�' � .�x, f rr ” r J s tri r Tri' 'r r�'C t,r,"m r f ��,� ,. r qtr,�.f>k€,��,j �✓r� ��riae �' �;i=�,� r r r r � r r - ' ,m-rr � : "fin r � '''�'r-�� "�l," '�`"tt'-.✓t���..u: fx ; i � . i s t n, 1 A of 1 � l� ti s i - +, f , 7,7 777 1F r f ✓Y ` ' t ;. 'P 4 1 a �s7 r ✓ AFt� Tr t r J l CERTIFICATE OF LIABILITY INSURANCE R2 1 777/2015 THIS CERTIFICATEIS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATIONIS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT PAYCHEX INSURANCE AGENCY INC/PAC PHONE AC o (AI1N,Ext): C,Ne): (8 8 8) 443-6112 250881 P: F: (888) 443-6112 E-MAIL ADDRESS: PO BOX 33015 INSURER(S)AFFORDING COVERAGE NAIC# SAN ANTONIO TX 78265 INSURERA: Sentinel Ins Co LTD 11000 INSURED INSURERS: Hartford Casualty Insurance Co 29424 INSURER C: TWIN STATE SUN LLC INSURER D: PO BOX 1855 INSURERE: NEW LONDON NH 03257 INSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPEOFINSURANCE ADDL SUBR POLICYNUAIBER POLICYEFF POLICYEXP LIMITS AIAUDD/fYY} COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE slf 000, 000 CLAIMS-MADEaOCCUR DAMAGE TO RENTED ce PREMISES Ea occurren $1, 000, 0 0 0 A X General Liab X x 76 SBU UI1461 06/22/2015 06/22/2016 MED EXP(Any one person) $101000 PERSONAL$ADV INJURY $1, 000, 000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE2,0 0 0 000 POLICY PRO-Ex LOC PRODUCTS-COMP/OP AOG 2, 000", OOO JECT OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) ANY AUTO BODILY INJURY(Per person) $ ALL OWNEDSCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) HIRED AUTOS NON-OWNED PROPERTY DAMAGE AUTOS (Per accident) $ UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE DED RETENTIONS $ WORKERS COMPENSATIONPER OTH- AND EAIPLOYERS'LUBRITY X STATUTE ER ANY PROPRIETORIPARTNEWEXECUTIVE YIN E.L.EACH ACCIDENT 1, 000,000 OFFICERIMEMBER EXCLUDED? B (Mandatory In NH) wa 76 WEG PH1146 06/22/2015 06/22/2016 E.L.DISEASE-FA EMPLOYEE 11, 000, 000 yes,describe under DE.L.DISEASE-POLICY LIMIT 11,000, 000 1 DESCRIPTION OF OPERATIONS below ,0 0 0 0 0 0 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) Those usual to the Insured's Operations. Please see Additional Remarks Schedule Acord Form 101 attached. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. SUNEDISON RESIDENTIAL SERVICES LLC AUTHORIZED REPRESENTATIVE 600 CLIPPER DR BELMONT, CA 94002 / ©1988-2014 ACORD CORPORATION.All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD PAYCHEX INSURANCE AGENCY INC/PAC PO BOX 33015 SAN ANTONIO TX 78265 SUNEDISON RESIDENTIAL SERVICES LLC 600 CLIPPER DR BELMONT CA 94002 ACORD 25(2014/01) A��® CERTIFICATE ®F LIABILITY INSURANCE °06/252015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WANED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such ondorsoment s. PRODUCER CONTACTE. PalchxKlnsurence Agency Paychex Insurance Agency,Inc. PHONE nl FAX No: 150 Sawgrass Drive Rochester,NY 14620 ADDRESS: 877-266-6850 INSURER(S)AFFORDINGCOVERAGE __ IUUC# _ INSURERA SenlmN lrSu,an.S C<+i����,� INSURED INSURER B:11ah!erd DraAlLs CnrsoSCakd A!!tialcs '.. TWIN STATE SUN LLC INSURER O: 101 MURRAY POND ROAD INSURERD: NEW LONDON, NH 03257INSRERE: _ INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS '.. CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONSOF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. _ __ G1$R-- - ODLTSUFIR ppLiCY EFF POLICY EXP LT I TYPE OF INSURANCE POIJCY NUMBER HIAA) MN �- - ----_ LIMITS GENERAL UABIUTY A _ X EACH OCCURRENCE f l0ca,roa X. _ )' �- t 1 ooe.000 COMMERCIAL GENERAL LIABILITY 1 CLAI!AS-AADE r -OCCUR MED EXP(My0ne p4Son) S 10N0 -.. 76SBU1461 0612212015 06122/2016 — — L� 'PERSONAL&ADVINAIRY S ICN GENERAL AGGREGATE S 2V0o uco GENL AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOPAGG $?000LN 1.101CY 7 1 FRO. _— LOC -_---- $ AUTOMOBILE LIABILITYCOMBNED SINGLELIMIT ANY AUTO BODILY INJURY(Por W—) $ F ALL Ol,NED AS r AUTO$ j AUTOS BODYV INJURY(Per avideM) $ C_-- AUTOSNONCIANEO I '—PROFERiY°AMAGE I_ i/!REO AUTOS AUTOS IPa aG'tlanll S __ UMBRELLA LIAB OCCUR EACH OCCURRENCE S {EXCESS LIAB CW MS-0lADE AGGREGATE 5 DED RETENTIONS S YIORMERSCOMPENSATION I X LIC STAN- OTN- B AND EMPLOYERWLIABILITY YIN l.-_ITOHYUM ANY PROPRIETORPARTNEREXECUTIVE E L EACH ACCDENT S 1 011.000 OFFICERVaE ER EXCLUOED9 N NIA 76WEGPH1146 06/2212015 06/22/2016 L'--- (MaOdaWrylnNN) lEL DISEASE-EAEJAPLOYE S "NO nyes.dewlno„order --- — 0 SCRIPTION OF OPERATIONS benx �E L.DISEASE-POLICY LIMIT FS ON NO DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD HH,Ad ftnN Remarks Schedule,If more apace N ngWnd) SunEdison Inc is named as an additional insured in regards to the general liability policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE SUnEdison Inc. EXPIRATION DATETHEREOF.NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE 600 Cil er Drive POLICY PROVISIONS.BUT FAILURE TO MAIL SUCH 140TICE SHALL IMPOSE NO PP OBIT CATION OR LIABILITY OF ANY HIND UPON THE COMPANY,ITS AGENTS.OR Belmont,CA 94002 REPRESENTATIVES rl ulonrze0 RrracsENmnvr, A I U1988-2010 ACORD CORPORA"..AP rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD '.. Massachusetts -Department of Public Safety Board of Building Regulations and Stanwaruo Corlstr Ul'LSon &Opel isor - License: CS-097790 PAUL F CANALI 28 AFONSO WA's MiIWWe MA 015,9 Expiration Commissioner 01/0412017 /� _ Ire Office of Consumer Affairs and Business Regulation 4 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 135714 Type: Individual Expiration: 5/1/2016 Tr# 251504 PAUL F. CANALI PAUL CANALI ------ ---- -- 28 AFONSO WAY ---- --- _- -.-_ MILLVILLE, MA 01529 - Update Address and return card.Mark reason for change. SGA 7 .:; 20M-05/11 Address ❑ Renewal ❑ Employment ❑ Lost Card ���P ((C/J//l/ON/I(C/�/�r�^/l rr.;✓r/r'�//J('//J Office of Consumer Affairs&Business Regulation License or registration valid for individul use only ill ,-',= OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: ^I registration: 135714 Type: Office of Consumer Affairs and Business Regulation 1 xpiration: 5!1/2016 Individual 10 Park Plaza-Suite 5170 ` Boston,MA 02116 PAUL F.CANALI PAUL CANALI AFONSO WAY MI I Undersecretary Not va id without MILLVILLE, MA 61529 l j thout signature _____ -_- -_ GENERAL NOTES. N.T.S PV P1 1.LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION 2.NO SHEET METAL OR TECH SCREWS SHALL BE USED TO GROUND DISCONNECT ENCLOSURE WITH TIN-PLATED ALUMINUM LUGS;PROPER ARRAY - 81 MODULES COVER SHEET GROUNDING/GROUND BAR KITS SHOULD BE USED. o 3.ALL EXTERIOR CONDUIT,FITTINGS,AND BOXES SHALL BE WITH RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS.(NEC 314.15A). ARRAY TILT=27 4.ADEQUATE SPACING ARE MAINTAINED BETWEEN ANY PLUMBING VENTS EXTENDING THROUGH THE ROOF AND THE UNDERSIDE OF THE PHOTOVOLTAIC AZIMUTH = 140`,50° j PANELS(6-MINIMUM RECOMMENDED OR 12-HORIZONTAL). 2 5.SEPARATION DISTANCE MEASUREMENT FROM BOTTOM OF PANEL TO TOP OF ROOF COVERING SHALL BE MINIMUM 4 ROOF TYPE-COMPOSITE SHINGLE 6.BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. 1 STORY BUILDING a o 7.ALL CONDUCTORS EXPOSED TO SUNLIGHT ARE USTED AS SUNLIGHT RESISTANT. ' vo o Q 8.PLUMBING AND OR MECHANICAL VENT SHALL NOT BE COVERED,OBSTRUCTED OR RE-ROUTED AROUND SOLAR MODULES.(10 MIN. CLEARANCE ��3 �� R 9.SMOKE ALARM AND CARBON MONOXIDE ALARM REQUIRED. 9W Y Y Y a 10.ALL WORK TO COMPLY WITH 2009 INTERNATIONAL BUILDING CODE;2011 ELECTRICAL CODE[2011 NEC]ARTICLE 690,ALL MANUFACTURE'S LISTING AND o v m o c INSTALATIO INSTRUCTIONS. UNGROUNDED INVERTER ® " N 11.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH STATE REGULATIONS.PROPER ACCESS AND WORKING CLEARANCE WILLBEul N N N PROVIDED AS PER SECTION 110.26 CEC. c9� N N N W z z POSITIVE GROUNDED INVERTER ❑ z z 12.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED,LISTED AND IDENTIFIED IN ACCORDANCE WITH UL1703 SECTION o) w rn rn o o R902.4I � Mem 3 THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN NEGATIVE GROUNDED INVERTER ❑ o cn cn co o U ¢ ¢: ACCORDANCE WITH NEC 110.26. ENPHASE MICROINVERTERS ❑ _ CD w rn 14.ALL CONDUITS AND EQUIPMENT SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND MATERIAL COLOR OF THEIR LOCATION. m 15.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC 250.97). 16.DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. THIS PROJECT SHALL COMPLY WITH THE ts 17.Al EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 2012 INTL BUILDING CODE(IBC) oQCD18.IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT,WIRE,EQUIPMENT DEVICES,OVERCURRENT PROTECTION,GROUNDING SYSTEMS,ETC.(ALL 2012 INTL EXISTING BUILDING CODE(IEBC) M m W EQUIPMENT AND MATERIALS)THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY LL <F 2012 INTL FUEL GAS CODEIFGC THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE ( ) THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 2012 UNIFORM PLUMBING CODE(UPC) OX W�w 19.ALL OUTDOOR EQUIPMENT SHALL BE MIN.NEMA 3R RATED. 2012 ENERGY CONSERVATION CODE(IECC) r$U> >} 20.METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 2012 INTL RESIDENTAL CODE(IRC) 3- g z 21.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. 2012 INTL MECHANICAL CODE(IMC) Y g a 22.FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEETS. 2012 INTL FIRE CODE(IFC) o W m le K Z) 23.ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ.THE AHJ MAY HAVE SPECIAL LABEL g �N a z o REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT.THIS MAY ENCOMPASS LANGUAGE INCLUDING,BUT NOT LIMITED TO,THAT FOUND IN NEC 2011 NATIONAL ELECTRICAL CODE(NEC) ARTICLES 690.5(C),690.14(C)(2),690.17,690.53,690.35(F),690.54,690.64(B)(7)AND 705.10 ORDINANCES OF THE CITY OF 24.INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. NORTH ANDOVER U L p o 25.THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED z o SHEET INDEX WCWY MAP LG ELECTRONICS-LG 305N1C-B3& �W o PV -P1 - Cover Sheet P6- Inverter Sheet W w P2 - Plot Plan P6A- O PtrmizerSheet �t`;"' SOLAREDGE-SE9KUS-208V W E ti LISTED BY UNDERWRITER'S LU W P2A- Roof Plan to Scale P7 -Rails/Grounding to N & ' ' LABORATORIES FOR ELECTRICAL CS o P3-Three Line P7A- Fire Rating Rails y' `- c� N P4- Rafter Side View P8 -Attachments AND FIRE SAFETY rS E '� 3 P5- Module Sheet P9 -Waming Labels (I;LA$$AFIRE RATING) _ o P5A- Fire Rating Sheet t �' Z Z Z 1)NOTE NO DISCHARGE OF ANY POLLUTANTS �i W 8 w -- TO ANY STORM DRAIN SYSTEM. U Z p 3 2)UL 1703 FOR MODULES&UL 1741 FOR INVERTERS iT3 m OV a X a P�pamdbrlalo PER CITY SOLAR REQUIRMENTS. ti �..4qa?.i4RPI%t6w wwaadarpa�mtrervkes.can ,� �' u ' 2011 NEC,CITY/COUNTY FT)•MAWNGS, Soler Permit Services,Inc. 94W2406 LABELS,AND WARNING SIGNS REQUIRED 3' DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. ._--_ -_------- SCALE —'KOM ll- _ PV-P2 _ PLOT PLAN POINT LOAD CALCULATION PER ARRAY WMIOSIVICEWANCEPON --...__.. A4WSHtNCEPANB.AI0ALD49CON1✓ECTE74�DS3' L NL4fEPRDECTAt�e110W�GOEiM5A0EPMV�B1'Q6TOAfrfl00.6E11MFTEDYLISHE1tfIE0VGBN'FA�70NWMgYN1 _ ITEM #OR WEIGHT TOTAL RMDB)9YO15IDYB1.PMaaAWRNOfABP01 WFORSIZENAtt1WAOSTHRTCOW DDM MNBBTDTNBE MW WNfN/CIONSKVLrAI�AILNECBSS�RYPRE77JRN1tSW1RIPf8'APBKi MGDMRSAWAWUYUHNfCDWVMTD&ftTWIN010IATNN10MfNNfDW01ANTWMDa0AFNI PM10 LIN FT PER Ibe LGM bs FORANMM Po1VrLCGINXS-BIMNGSSPoICNPEKIEOWSY ISTHE BEBBDVBMW06TCMANONSTAMAMOOMBORLD00.CAMMMTNBEDDanA SCWANDOONMTION (� MODULES 81 38 3076 WSpCN5IBUTYOFTHE 067ALLER ORWMUMAYAD MWKON6MMMD67AtLOMMLWBESUOMMMMPAWaMANDOBYAWIOIRTAUIWWB m „r<p RAILS 550 .5 275 AW��7SWYBEBEXMDUETOEXISfWFDW UYWE. foBAPPMN/I (� '^ 40 RACKING PARTS 150 .5 75 2RUMMAl®MM7NEAPPROPMWPANELCUW88TAESAMDNMMICUSANDPROIBIUAES01N91GYKPWAUAWN Z TILT LEGS WA 3.5 WA 2DIIISIKOANDINSfElWMrALC E -NMCLEWO,ALLWMBNAMLRET PPA NGft RUPROaMWSANDMEIHNNSCDNDRBUt WUMPGEMMEMWOW185ORMAYVM FW Ili �O OPTIMIZERS 81 1.7 138 y d U 3586 (0B) N0� 3PAfE1.CUW N8AY8WPdE(SNEUI9NUBtEDPoRIpEASIwALTFPfANE1ffN18E6¢9FLODGL001�NON81 J U U U NONACCESSPONTSSH4IBELOCATBIKAREMSTPMTDONOTPEOIS DE GROMllANGOFMMOMMSOtaOMMPMArESTUREMMOEtNVENAWAYSBffMENOiMWRDMR ! W O O 6 #OF MOUNTS 3566/150 =23.77 LBS PER MOUNT PEACBI OFGiMM LADDESOVERMe*=SUGSASWKDOWSORDOU6, ECHMWULE PRIAWgACTWEL10M �IA --- LBS/PER 50 FT 3586/1430= 249 LBS PER SO FT ANDLOGT®ATSTPOWPOKMOFMMDNGCONSTRWn IRLOCATNXS W Y Y IIS wNEAETHE AM=POW BOB KWCONRKfWITH aA3WMOBSTRwnaA � p� MMASTRMUMMB SAD75. WRESCR i ! q rv- 250'-0" 130•EXTETi10R 314'EMT DG CONDUIT LLJ W — — — MIN. 3.S ABOVE ROOF U ILL" N N LABELED DC EVERY 70'(TVP) I J , (0 In co DRIVEWAY J-8OXON ROOF A SEALEO TIGHT I Yn NON-FUSED-NEMATYPE3MIN. ARRAY4M (N)(3)INVERTERS-SE 9KUS-208V I W W W 36 MODULES WARNING LABELS, ROOF TILT C 27" OUTSIDE ———— ARRAY#2 CO ROOF AZIMUTH C 50° CO 30 MODULES Tor FIRE SET BACK (N)150 AMP 208V SUB PANEL —IROOF TILT a 27° m Aq LS 8 ATTACHMENT(TYP) OUTSIDE I I ® ROOF AZIMUTH X140° II I VENTO(TYP) H 2 xi 0 CO aw FIAT ROOF I < 4 w a D- THI zi o� I I �i 2 Z;{yL W I n yl muco >} PARKING LOIS 7� (TYP) I o 15MODURAY#3 S i U Y g `�< Q ROOF T?LT(M27' I I WII( W o CD TIn O$M O I ROOF AZIMUTH @140° a o Z O II ¢ 1 I a (N)125 AMP AC DISCONNECT OUTSIDE /// I N 0= f III OUTPERFORMANCE METER SWINTERIORIEXTERNORI-EMTAC CONDUIT 37-.0- I U Z U Z OUTSIDE (E)200AMP MAIN ELECTRICALSERV CE 2HWIDIGP I 1'_ Q OUTSIDE PANEL i Ur CQ,D ZO METER#72988012 ' / r W DRIVEWAY W U w — — — — — — — — — — — — — — — — — _ — W Cn w 290'-0"P2 �� NV MONT �( w¢ —170 PLEASANT ST N w ——————————————————————————————————————————— ———————————————— —— Z _ 2 PARIOZNGSTALLSIRIPING aETTPI arm tlAm r� GZj w ® O3BIfI1M1(DTP.T aPODb1Pi (BPBTImlq(fiYP) Z Q W K z AONCDRTO �i W J M�nDwxoxmmaw®iw�mrAPVAMamsrAa 'AD�Nrro sEDerawrtPaeslme PNDmu EA 28#1®DLawtwllheLEMaaaanmvmxxlmEPiFTxmAEarWt ® ® ePAl'NMDfDOD®StM01NLL99101LNOf xaD1n M1M8) UZQ NOTE SCEMAWOFM _O 1.NmDWlm InU=ri x 0' 2' S 10' 20' 30' 50' - m ywQ sRN/MEiMOcaTacFvnxr 3COAnM1N0T ..cesaan.�•,'•"•."•-"`•,—nm:v�:.nz .r ."'.'•"`•'•`�`"",."°`-„""" 1116"-1'-0" &Owsr9HALLE031IB®NOPN?DCOPsruL I} ' I,�, SONESY10oLPEAIWmIgPPAR®lOSNAL `"�l'*P)76�EDOE TO EDGE 76- IGETOEDGE 8'-0'FOR VAN r DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction andior fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. -. __....._--______. __._ ..... . -SCALE ____— —- 3132's 1'-0. I PV-P2A I ROOF PLAN I per" 160-EXTERIOR3fCENRDCCONDUrr ARRAY#2 --ll mmp �^y MIN. 3.5'ABOVE ROOF 30 MODULES U N p,.w,•.,, } LABELED DC EVERY t0'(7'/P) ROOF TILT @ 27° Z CSI U U U J-BOX ON ROOF/SEALEDTVPE3 MINT N (n ROOF AZIMUTH @140* 1-F-LU NON-FUSED-NEMA . r _" c _L------_— ——--_— � ` WU O U Q ERTERS-SE 9KUS-208V(N)(J)N IE L48ELS, OUTSIDE W �e ARRAY#1 zSC _ to 2.4024'0.C.CTYF)24'O.C.RAFTERS 36 MODULES IN)160 AMP 208V SUB PANEL - OUTSIDE WW N N N ROOF TILT(A 27° RAILS 8 ATTACHMENT ROOF AZIMUTH @ 50° I I W U W W W N N N W W W 0 I �M VENT(rYP) _ I � n F ® � F FLAT ROOF =O 2 p W O� �F I ------ 00 C.) 0 ZISWS'O.C.RAFTERS U O Y Q a (fYP) WI W o 0 � (A U n N d�Z 0 N D_ a O H a U— I- (N)116 AMP AC DISCONNECT _ Z U = OUTSIDE } O Z Q dal (N)PERFORMANCE METER 160'INTERIOR/EXTERIOR I"EMT AC CONDUIT Cn O 2 OUTSIDE WW Z U 4o O.C.M (E)200AMP MAIN ELECTRICAL ARRAYB.i AX lW ; wa 12' PERCITY40UNTY r SERVICE PANEL 15 MODULESN DI �Q T� REOREN10— �n'AnN7eeirTYr OUTSIDE ROOF TILT @ 27° lDINISN101NQt 0UMAy� METER N72966012 ROOF AZIMUTH(83140° O E Z Ra D 2rn zZZ W�� A ' "USELECTRONIS-LG305NIC-e3 U O Z 39.37"x 64.57" I610NONG IaIIaNlorcZ= am.mm. na,m. 3s.37^ FRONT D]'t U 0=.. X SCALE 0' 2' S' 10' 15' 20' w 170 PLEASANT ST 3/32" PORTRAfl PANB.S DETAIL LAYWT NOTTOSCALE DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawingS,Specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. PV-P3 ELECTRICAL NOTES: THREE LINE ELECTRICAL Ei.ALL EQUIPMENT IS LISTED FOR USE E7 t.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E2.MAXIMUM VOLTAGE DOES NOT EXCEED 600VOC. EIZ.BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAI�R. E3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED E13.ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. PIECES OF RAIL THAT 2 E4.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION ARE CONNECTED AS AN EXPANSION SPLICE. BOXESICMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E14.ALL WIRE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. LS O E5.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. Els.INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. I Z Aj E6.ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT E16.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. U U U COMPONENT. E17.ONLY COPPER(CU)CONDUCTORS SHALL BE USED.CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. I to v U LU E7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY Ela.DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. C9 GROUNDED. E19.ALL MODULES AND RACKING SHALL BE GROUNDED USING 2703 UL LISTED RAIL INTEGRATED GROUNDING SYSTEM,OR WITHTIN PLATED DIRECT -,W L)p UQ Ee.DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM(SOLAR EDGE INVERTERS 50OVDC RATED MINIMUM). BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE,STAR WASHERS,AND THREAD FORMING BOLTS OR WEEBS. !q N 3 3 jj E9.MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT U ly1 `1`L Y MIGHT BE ENERGIZED. 0 8 un E10.INVERTER(S)SHALL CONTAIN AGROUND FAULT DETECTION AND INTERRUPTION DEVICE. IX Or co li ISDBNGOFI3PANW& 1STMGOFMPAN7S& iSRRORGOF I3 PANELSa ' ,11 STRNGCF14PME(S 1 STRNGOF14PM4BS 1SMNGOF14PAMS � N N N I CALCUTATiMS FORCiRW@lTCARRVBdG CONDULTOPS: CAICUUTIaHSRJRCURF@7T CAPo0INGIXN♦DUCTOFS ' - aP6 - _- (W7 NNN AC RE-OIIRED CONDUCTORAMPACTTY DCREDUIREDODNDIICTORAMPACTTY ■ I L� l I J 25A/1.732'125.1&04A (NEC69MXIB: II_ 00, a AWGa10DERATEDAMPACTTY: 1&1'125.125.15.78A 1'.idl-POWER OPTIMIZER I I I I I II (10)(091)(1)=36AOA AWG#10,06RATEf1AM+ACTR: UNDEREACH MODULE H U,W 35.40A>1894A,THEREFOREACNIRES�ISVAtID. (40)(058)(0.8)=i8b8A p V)lA fn FROM INVERTERS TOSUBPANEL 1a56A>7&7aA,T{l3tE EDCWBRES�iSVALID. I I I l II °C I > U) CALQRATIONSFORWM31TCAPMMCONO MRS: <� tt a J J Z ACREGUOMOONDMDRAWAGRY J-BOX ON ROOF SEALEDTIGHT-� 2 (CC222:--j W M 25A11732'125=1&WA-3-SCI2A NON-FUSED-NEMA TYPE3 MIN \ 1101611E 01nSLE OUfSOE j AWG#BDERAT®AMPACItt: (ttP.) I6AiDUND131 UNGROUNDED VlltVirnllU� ps)(6m)(q=662sA J-eox INVERTER 83 Jaox INVERTER#2 J-BOX INVERTER#1 6825A>54.12A,THUM;DFtEACWMSt2EBVAUD. IN) TY PERFORMANCE METER ADJACENT FROM SUB PANE.TOIMIN PANEL TO MAIN SERVICE PANELIO'TO 72"CENTER 901ARBxE TO CENTER OF METERS&49'TO 75 ABOVE SEW AS SE9aL6iWV 9EU9.31N � Z I- GRADE LEVELPV METER PROVIDED UPON j WX SRC.89514 iNY tiFlG 86914 WX .983X, m = TD j I I LOCAL UTILITY COMPANY APPROVAL W 0 OD Un I 1,,j I I 11 I 110. LL p W TO UTILITY GRD cN)125A mI44NPAX� Q} 208V DSCOA208V AC I xvmc I EGO I EGCmrm ( Q W H THREE PHASEtE CENTER PED PANEL DISCONNECT L a, F Q: MAIN LOCKABLE BLE IFEBL3POLEL + - + - + 0 _ a) BI j LOCKABLE KNIFE BLADE, TRICAL PANEL I NEMA3R 6.36 NEC690.17 O 0 f j g U BI-DIRECTIONALZ UTILITY METER200AMP MCB .NE SIDE TAP 0JI69t xD=NvSvVS L EC L FS. L U I-- 5 METER#7298801 (M 150A 208V PV I w W o0 LOAD CENTER ONLY _ O m 1- 2 U 3-20A3POLE BREAKERS 4 SEXTERIOR3f4" Ix D. U ENT DO CONDUIT I tl N D. r O l (4)#10CU THWN.2 I r CONDUCTORS I (1)#aCUTHVVN-2 I I _ I I GROUND l I N a - - L--- 90'CC VVET&DRY I_ F Z I (TY t I I Z v ---- -- -150'INTERIONEXTERIOR 1"EMTJ r___= --_-_-_-_-_- I---------� z W 31� MOUNTS AND EQUIPMENT I AC CONDUIT ENCLOSURES GROUNDED J- (4)#6CUTHWN-2 CONDUCTORS LLI Q TO MAIN PANEL GROUND `°' (1)#8 CU THWN-2 GROUND (E)LIFER GND WC WET a DRY r Cl (1)*6CU AWG BARE GROUND WIRE CV BONDING MODULEAND RAIL NEC250(TYP.) ISL Z= (�(4)#10 CU PV-WIRE Z Z Z z 1t NEC3W.6C1(TYP.) R-1W Z m 2 03 150 EXTERIOR 3/4'EMT DC CONDUIT u O Z U Q (4)#10 CU THWN-2 CONDUCTORS V Z O CEC 690.8(A)(t),(B)(1)each ISC=101'7.25'1.25=15.780. (1)a 9COTHWW-2GROUND -O= X0 PANELS RATINGS' INVERTER DC MAX INPUT CURRENT=26.5 A SUB PANEL PV-CB SIZE 200.PER INVERTER gPC WET 8 DRY(R'!P.) LD PTC RATING IS 276.9 W INVERTER AC MAX OUTPUT CURRENT IS: m d'U Q. X m )•n ISC= t0.t ADC VOC=40'1.13 =4520 AV/DC Nmpl is 81'276.1 0.96511000=21.64 KW-AC(CEC) IMP= 9 52 ADC Input Voltage 365114=26.07 Vdc modules per string 25 A 11.732'125=18.04 A PER INVERTER C)6 EXTERIOR y4'EMT DG CONDUIT 81'276.911000-22.43 KW-DC(PTC) ppa0 CU THWN-2 CONDUCTORS Input voltage 365V =20.07 Vdc modules per sVirl9 Total a235W/365V =22560. (1)88CU TINVFI-2 GROUND ni m2 a INVERTERS DC MAX INPUT VOLTAGE=500 V/DC g0'C WET&DRY(TYP.) , _. DISCLAIMER:If any Errors,Discrepancies or 0m-Lssions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission-In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of arty errors,discrepancies or omissions and the cost of rectifying them. N.T.S PV-P4 SOLAR MODULERAFTER SIDE VIEW UNIRAC SOLARMOUNi END CLAMP I I I I gj� UUU 1 11 ~nr ~nv - c3 r �STANDARD SOLAR MOUNT BEAM W UvU �Wa o¢ Y Y Y L-FOOT j uuu��7 318"-15 x 314" v N HEX HEAD BOLT EXISTING 12'COX PLYWOOD W N N N 318'-16" SHTG.WITH UNOERLAYMENT U' LU N N N LLJ FLANGE NUT OVER 1X6 SKIP SHEATHING J cn Cl)Cl) �o j W W W to EPDM SS FLAT WASHER'�y QUICK MOUNT PV 0 'X3;"SS HEXBOLT COMP.SHINGL z D w IDLO j O i 2 GaLL NOTE SPAN OF STRUCTURAL ATTACHMENTS O ~ 5H6"x3-12SSLagBoft@4'ocMazwith 2-10Penstgonand Ior W ce C' 5116"x4.12 SS Lag Bot@Vo.c.Maxwith 3.12"Penehabon $U> j WerexMNSHT'G.ardnxafraftarasshown V PER MANUFACTURERS SPECIFlCA710NSrI O Y g zd n¢. 2x6RAFIE2 a i6"o / oI w o a) C a �Na�z0 3' M DULES PARALLEL TO THE ROOF m ABOVE ROOF SURFACE a o zQQ U O 65 �c6 � �3II G� W W� i m��n 3: zz o 2x6 RAFTER Q 16'o.,/ ENGINEERED TRUSSES I O Cd w r� U zU m�tUd xv—m� y 9 } DISCLAIMER:If any Errors,Disaepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor Will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. N.T.S PV-P5 ........11 i, MODULE SHEET _,_tG- Wchanic,d Properties Electrical Proper ie<(STC W 8 Y Y u, 41,1r l c l r v m W0N N N \ ` _I Electric,(PrA - W W W m i.r,.:1„r..d,.,,. -op r.,es(NOCT*) _ }}} Certifications and Warranty ryry y Lr Lh r u co 0 - pTemperature Coefficients Dimensions(mrnlin) 0., M H --_ W c) { -p, Q> �} � 7'� ll�Vn�nll V 601uu, W �,s Chaniterl+tic Carves _ Ww n W 0. U a �c�va��z0 ar �, N - Nea,,Ze o UD(I - n It d„�er�) w Tupe lt7aterlat �^ i __ _— `'�, N � $ olimpL-- U ° o �z - Q _ W� o _ 1 . Nano Lcvct Controt Doub -Sidcd Colt Structure ,.� _ U a i zz =� L 8 W w I m0:c 2�.Al� m y C-)a X R LGm S LIM ----- --- DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents,The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. - ------ - - N.T.S it PV-P5A r Intenek Testing Services Shanghai Intenek Tessin®Services Shanghai FIRE RATING SHEET �� Building No.86,1198 Oinzhou Road(North), Building No.86,1198 Qinzhou Road(North). Caoheiing Development Zone, Caoholeig Oevclepmont Zone, Shanghai 200233,China Shanghai 200233.China Te1:06 216127 8200 Fax:86 21 6495 6263 To[86 216127 8200 Fax:86 21 6495 6263 ' Z UUO This is an Annex to Test Verification of Conformity with Verification/Report Number(s): U U U 141101643SHA-001-V11141101643SHA-001,d40815004SHJ-BP-1,140815004SHJ-BP-2. LU o O On the basis of the tests undertaken,the sample(s)of the below product have been found The issuing office is Intertek Testing Services Shanghai(Address:Building No.86,1198 Qinzhou Road w 3 3 3 to comply with the requirements of the referenced specifications at the time the tests (North),Caoheiing Development Zone,Shanghai 200233,China) were carried out. j ,4 tl f N N N III Ratings and principal characteristics C7 u) N N N Applicant Name&Address LG Electronics Inc, J r to rn o) Max.310W,Mm 25OW W 168,Suchul-daeroSolar Business Division(Solar Module Fire Performance((for modules with below specified construction only)):Type 2 Factory),Gumi-si,Gyeongsangbuk-do 730-903,Republic Superstrate:z 8-4.36mm thick >_y F- of Korea Encapsulant(Super/Celt):0.25-0.55mm thick Encopsulant(CelllSub):0.25-0 45mm thick U O(e Manufacturing site Name 8 Address Same as applicant Substrate:o 285mm-0.3mm thick. ro Product(s)Tested PV Module Model(s) : !, Ratings and principal characteristics See Annex 1 j LGxxxS1C-A3(xxx Is the number from 250 to 280 In step of 5), F tY Model(s) ...See Annex.1. . LGxxxS1 K-A3('xxx'Is the number from 250 to 275,In step of 5) „x Z F- LGxxxS1 W-A3(xxx'm the number from 250 to 280,in step of 5), m > v Brand name LGxxxS1C-63(xcx'is thenumber from 250 to 280,in step of 5) ` m O tc Electronics LGxxxSiK-B3(xxx is the numberfrem 250 to275,in.step of 5), I 2 WLL I LGxxxS1W-B3(xxX is the numberfrom 250 to 280,in step of 5), O F lGxxxN1C-A3('xxx'is the number from 270 to 305,in step of 5), : 02 Relevant UL 1703 Issue:2002/03115 Ed:3 Rev-2014105120 UL w F m LGxxxN1 K•A3('xxx'.is the number from 270 to 300;instep or 5), to Standard for Safety Flat-Plate Photovoltaic Modules and LGmxN1 W-A3('xxx'is the number from 270 to 305 in step of 5), m ti to Panels LGxxxN1C-B3('xxx'o the number from 270 to 310,In step of 5), N p rn Clause 31 Fire tests LGxxxN1 K-63(xxx'Is the number from 270 to 300,In step of 5), 3 Cr Z Z LGxxxNt W-B3(xxX Is the number from 270 to 310,In step of 5). 0 Y g ¢a Verification Issuing Office Name 8 intertek Testing Services Shanghai w tr n O Address Building No.86,1198 Qinzhou Road(North),Shanghai p �wq l'U IX U 200233,China a a N a o z o Verification Number 141101643SHA-001-V1 Report Number(s) 141101643SHA-001,140815004SHJ-BP-1, U Fes_- o o 140815004SHJ-BP-2 Z v z Z _ NOTE:This verification is part of the full test report(s)and should be read in conjunction with it W W o0 NOTE:This annex is part of the Test Verification of Conformity and should be read in conjunction with it. Z Ci This Vamtoian m for the azdse usem uof Ialarok's Client and is pmvidadursua pnt to the agreement bohveon huhtak and in Client.otertok's W al , a. ecponsibitity and liability are limited to the loans and mmritiarls of the agreement.Intertek assumes no liability[o any party,other than to the Client in Thu Venficanon Is for the exclusive uu of hhorok's client and ie provided puro am to the agree tit betwean intertek and its Client _ } a accordance rah the agreement,for any loss,expense or damage occosloned by the use of this Voe6canon.Only the Mont n authorized to copy o .bd-whionceo m the CVO Ur and Mindy are Malted to the temu and conditions al the agreement Iniartek assumes no liability to any party.other than to tela Client In gcmrtlanca frith tele distribute IN,Vorigcmion,lay use of the Intenek nano or ono of its marks for the sale or ad-irlaomenl of the farted material,product or Mirvico must first agrtt ens,for any loss.expense or damage occasioned by the use o1 this Venrlcaler,Only the client Is authorized a copy or distnbule Ims VenI--a. Z al 3 th,approved in vrtifing by Intertek.Tho observations rind test.-It.reforonced from this Verification are,reI—m only to the sample hhuod.This qny ace of the le—ok name or one onto marks for ine cola or atlromcemom of trio tasted material,protluct or sarvlo�must first be a➢➢roved m vmUng by O� W i5 Venfi—tan by itself does not imply thet the material.product,or service is yr has ever bean uMar an Intertek wrtllicatmn program. Intertek.The observations and lest Im,alb,reforonced from th,Venhralron we relevant only to the sample testod.Tells Venticatron by itaelf docs not Imply 13?11 m U ((� riot me material,product or or nos o er M an under an Intenek cemf alien progrom Z Z Z $ Lli Ll Ww z Signature Signature m Z 0 3 Si MOM Name:William Cheng m a U(L X iii i5 Position'PV Name:William Cheng Position: Date:06 January 2015 Date:06 January 2015 _ DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of redifying them. Three PhasFe Invert✓ers for the 208V Grid for North America INVERTER SHEETsolar=@ S Eli KLIS S 6 �' 1,1 rt7 SE KUSS14.41CUS OUTPUT VA Zj t Ar oulllut fr_Ou.l. .li!,:,.ui. AC pr -.r t -I .� .as , _y VIC SolarEd a Three Phase Inverters mt, w o o a f®r the 208V Grid for North America A,- YY� A AC r Ru 1 n N yl-,.' SJ.' U..�� o Ma U A N N N N CF91',U�; �. 1.i� ��� Llt W o n W r r P r e r, O N N N f_p t Cl)W fn INPUT 1 ^.,^ _.... 1 .. ¢ W to W M Po ,V on n n F F-F U v 0 W W W NHN 4. M al[ Dr w G 2>0 300 Vdc CRI YY> Y, P Inpal/ DC'.a L c Vdc N P/.mmol.rputV tG „C to Grd 700 :tic ;3 co �.e.re. N ! 1 [ DC is -(1 'r rl F C t - d, s Ad, chi 12��5 A al! ,, � artagkY s' w r i F-11 I I[o D'._-n,n 1M^ ..:ty � Z �H EJ W 0 W ` ADCII ZONAL FEATURES t O ` N' LL Q} oc t ,a s r 13 I.t � O O h E R„pv ,,td,.. NEC.,,46112 _ W,tn ,.al ae...c r lad'/u,d.,.,,r _. _. qqW Q'W F-,pr, m U� e0 R STANDARD COMPLIANCE tFn�+ v 'w$f,4$ „ t _ .. 'J 1 9 L L 1 F f A �� r�Zf J C o Z 11 .£ F a.. C ,�,r,�,c.� E � Or Y� Q Qa 6 v T INSTALLATION SPECIFICATIONS ..... _.. _.. _. '� W�0 U . N!i O9 C) ..(put I.e 1 A O I� i, n t n J .VG rmp. cin a Fu -1_f DC 2Pairz q, v r n.i Ef t 'C.2 ) _ V F 0, D 7F z .12 U N F t R't Z D U 'The best choice for S®IarEdge enabled'systems W } a wQ Inv,cu'.d Lq arc tlult praLectiRn tur h![C 2012 590.11 `'°""" `' '��'�� �� ��C.�j N jPd Ilutdown for NEC 2014090.12 _ Ou: s 71 d l(,dour m aUutfc7 Z rnZ Z� bt t1 owI lc l u on for n 1,;zuncl comlccti*n through(thuneorcW c s � r rigs �Z 0W —.sma, _.ligh.& 8ht an.,eav sy to u�..4,1 on Proo_,:nnckct W 0 Z cA 9 Z 0 �.Fi),al volt Cr.owert"DC/�C con-rslon only 0 03 p S""'Ch Fad-U a X m DISCLAIMER:If any Errors,D'wepancies or Omissions appear in these drawnngs,specificationsor other contract documents;The Owner or General Contractor shag notify the Designer,in writing,of such error or omission In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of arty errors,discrepancies or omissions and the cost of rectifying them. ---------- ........... ------ N.T.S I PV-P6A Solar=@@ SollarEdPower0ptimizer Module Adged-On for North America OPTIMIZER SHEET P300 I/ F320 P400 P405 F3C0 P320 solar=@@6> P-'-D P405 "_2 (I"t li,fit, INPUT r"Ie""put DC no SolarEdge Power Optimizer Lu UU Do< 80 I's va, mt—) Z Lu IV C't -"5-105 Vd, PPI Module Add On For North America Ad, DC R Z� P200 P220 P41-00 Il; P4.05 I UIT'ri "y ;�' ED 0 wt�!W.UU, cl) CO U)U) OUTPUT DURINGOPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) (1;1 COU)M i 15 W LU Uj I- TA""�0',tp.'V"1'.-'f1" V",: U)W 0) OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF! 0 P"'P""er vd, STANDARD COMPLIANCE E N,C C�il,,L I-5 f,.E�C,1030 EC61000-6-3 M,2109-1(d,- UL17-I'l Y" I INSTALLATION SPECIFICATIONS Z F_ Two CCl) M,---AHO—d Systeni Valto�,o2 iW 0 W W) ITI-1 Afl SCII L ul h,"?IT"I Th(I t E;W 1?S,:1 35 122,112 4P/ <>L IVJ H) 5 s7,1,08 5,5.-1.1 17 5 �9;,I S 0 2 2 of 770,11.7 11 2.LS . F3 U) I"i"a 'Lt.' U>_ C),Ipw WV,T}pv C,,t D.Ijbi, 0 a bo 0951 3.0 1 2 3.9 ul of Z 0 P t vviIL -' -4 0 'SSi_4o_1iSS CSI° VI 10E P, rP WI W 0d > 0 0 as_Z0 PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 209V THREE PHASE 480V C-4 A MI—AL IT Strmr I_,�.,Pth L SOLAREDGE NVERTER''' 0 S50 Z:) Z (v< Stnnit Le�PTII 25 2S (P <C" 0 5: LLJ feta I ft,"e,PC,St-P, 5250 LL, Z Lu Q W r:,r 0II 6PITun-, Lu(j) PV power optimization at the module-level a CA Up to 25,/,moro ril"fe"i S'pu'r ErZ Nlingate, ,d typ�or from MUnu�umlrinj'tole"r,"fice to parala l Z Z Lu OW rlLxitok��Y'tem de'ip'n"C'r'nximurr'5pace cD 01. Z Fast.I n 11 to 11�IT o IT w I �Z R I),,Single bo(L 2 6 :W1 Jrxt SQiIQr3110i)main�crarCP wlmmoaule-level=n(to"Im'Z 2M x . X ctiPd fitehIChte&,,-',t F0 8 3CE In R. a 'V .................. ---------- DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction andforfabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. ---- —Y N.T.S PV-P7 1 RAILS/GROUNDING SHEET INSTALLATION GUIDE Z� --- SYSTEM GROUNDING BONDING CONNECTION GROUND PATHS Y a � UUU fflO O Q 7 ftp w O r` } N s ql s t NN d h L goo " i� Q www r RAILTOLFOOT w/BONDING TBOLT BONDING MID CLAMP ASSEMBLY }}} N WEEBLUG CONDUCTOR UNIRAC P/N 0080025: ° ��"�-•- Apply Anti Seize and insert a bolt in the aluminum nil and through the ctearance hole in the stainless steel flat washer.Place the stainless steel flatsvasher on the bolt, , -- ..,- oriented so the dimples will contact the aluminum rail.Place the lug portion on the bolt and stainless steel flat washer Install stainless steel Rat washer,lock washer and '- nut.Tighten the nuc until the dimples are completely embedded into the rail and lug. F— n Z 0 r� ey p CO to pe L o w O Q} T-�` !CZ,°pin to 00(0 80 CO O Y K zd a.uGlDRusmtuGr Tot % ---- w c O 13- -\ ( .q t" END CP ASSEMBLY O m tom; V —QQI C_. __ LAMRACK SYSTEM GROUND . ... n .. Z O Y ILSCO LAY IN LUG CONDUCTOR-UNIRAC P/N 008009P:Alternate Grounding Lug �? l N w -Dnll and bolt thru both rail t+alts per table. U►_— O o �Z v z Q� ¢s 05 Ul �O U H • ,i_ _ O0O Ho �� ZW +d ©2008 UNIRAC. INC. acs w� t�3 S p in Installation Detail �� "m` � i o - � tz�(jzJ Qz_ z� SolarMount RailBONDING RAIL SPLICE BAR LL LL Z w L-Foot Connection f � 3 v W o Z �< M z O �U a X m i DISCLAIMER If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction andforfabrication of the work,the Owner or General Contractor will be held responsible to the result of any erors,discrepancies or omissions and the cost of rectifying them. APPENDIX 1 X G CLASS A'FIRE CERTIFICATION aI� a ________-___i___________________________________________________________ a _______ The SOLARMOUNT system has been certified and Listed to the UL 2703 standard (Rack Mounting Systems and Clamping Devices for Flat-Plate Photovoltaic Z Modules and Panels).This standard included electrical grounding,electrical bonding,mechanical load and fire resistance testing. �ilf FHW W d U In conducting these tests,specific modules are selected for their physical properties so that the certifications can be mostly broadly applied.The following lists yW DEQ the specific modules that were tested and the applicability of those certifications to other modules that might come onto the market. ZW YYY In addition to UL 2703 certification.Unirac performs internal testing beyond the requirements of certification tests in order to establish system functional Limits, t� allowable toads,and factors of safety.These tests include functional system tests,and destructive load testing. Or v m N NV N N Mechanical Load Test Modules System Level Fire Classification W O iti I:Li lir The modules selected for UL 2703 mechanical Load testing were selected to The system fire class rating requires installation in the manner specified in the N N N represent the broadest range possible for modules on the market.The tests SOLARMOUNT Installation Guide-SOLARMOUNT has been classified to the system levet U)U)� performed cover the following basic module parameters- fire portion of UL 1703. This UL 1703 classification has been incorporated into our UL WWW FW-FW- 60 cell Framed modules only 2703 product certification_ SOLARMOUNT has achieved Class A system level N performance for steep sloped roofs when used in conjunction with type 1,type 2,type 3 Q - Frame thicknesses greater than or equal to 1.2mm _ ZZz in t/1 r/) - Basic single and double wall frame profiles(some complex and type 10 module constructions.Class A system levet fire performance is inherent m — the SOLARMOUNT design.and no additional mitigation measures are required.The fire M frame profiles could require further analysis to determine classification rating is only"and on roof pitches greater than 2:12(slopes>2 inches per applicability) foot,or s - Clear and dark anodized aluminum frames above ther oof deck to There maintain othe Class A tireYr citing for<SOLARMOUNT. j- Certification loads 50 psf up- 113 psf down F- W c Dvnod..Dc System Levet Raft !: .Module. Mitigation ( n p CO In �., r tures T--_ Module Type - -r,., - ` s>Az• _ _ Fire Rating Direction Orientation :Required o a Sh LL HType 1.Type East west Lanpds fi po OR O H c2.Type 3. 6 .— CLA None Req.ir d Q — --- --- — civ T e 10 UJ North South o cart U0 Cn o�ga � wl F.: O RL r PAGE 1 c�<Da;�ZO o NOTES ' N 7 .. .. ... [ Z V 03 i a If PAGE ----------------------------------------------------------------------------- ZW SYSTEM LEVEL FIRE CLASSIF9CATBOPS ------------------------------- _ 3 a The system fire class rating requires installation in the manner specified in the SOLAR MOUNT Installation Guide.SOLARMOUNT has been classified to the system Level C7 g o z w a fire portion of UL 1703. This UL 1703 classification has been incorporated into our UL 2703 product certification. SOLARMOUNT has achieved Class A system Level o N w3 performance for steep sloped roofs when used in conjunction with type 1,type 2,type 3 and type 10 module constructions_Class A system Level fire performance is it ZZ =rn inherent in the SOLARMOUNT design,and no additional mitigation measures are required.The fire classification rating is only valid on roof pitches greater than 2:12 Z Z (slopes> 2 inches per foot,or 9.5 degrees). There is no required minimum or maximum height Limitation above the roof deck to maintain the Class Afire rating for N SOLARMOUNT. (�Z O tiiLU w ----- -- -- — -- (�m Z=X a 3 Module Type System Leve!Fire Rating Rail Direction Module Orientation Mitigation Required Fn 8 Type 1,Type 2, Type 3 &Type 10 Class A East-West Landscape OR Portrait None Required North-South Landscape OR Portrait None Required v DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contact documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cast of rectifying them. ........... .............................. N.T.S PV PS ITEM THIS EDGE TOWARDS ROOF RIDGE NODESCRIPTION, QTY. ATTACHMENTS SHEET I FLASHING,9"X 12"X.049',5052,MILL I 2 QBLOCK,CLASSIC,A360.1 CAST AL,MILL I > HANGER BOLT,PLAIN CENTER,5/16"x 6"_ 3 18-8ss 1Y Fav WASHER,FLAT, 19/64"ID x 7/8"OD x 1/8" J O1 6 EPDM I WASHER,SEALING, 5/16"ID X 3/4"OD, W Y Y Y4 RACKING COMPONENTS EPDM BONDED SS 2 It Ell 5 NUT,HEX,5/16-18,UNC-2B, 18-8 SS NOT INCLUDED R 0 N NW 0)cr) 7 WASHER,FENDER,5/16"ID X I"OD, 18-8SS to 5UJ UJ W 8 WASHER,SPLIT-LOCK,5/16"ID, 18-8 SS FJ rrwo NN 'Wo wo 8 FJ� 11 ,---C6 z 0 ED En 10 LU 'zLL. < 0 WO ul-) 00(0 g8 z CL 0 M W rl�ED 0 a. > 0 i a-;2 z 0 0 z v z a z W 0 W r UZI Q W Quick Mount PV W >. C14 TITLE: M =C" z QMSE: QMPV E-MOUNT zz zR W wW Qz 8 z Zo UNLESS OTHEPWISE SPECIFIED: SIZE DRAWN BY: RAD REV Fn C):C r�III DIMENSIONS ARE IN INCHES Fn--t 0 a- x TOLERANCES: P90PRIUACY AND CONFIDENDAL FPACTIONALt V5 A DATE: 9/12/2013 I.EINIORM-10 CONTAI.EO 1.TH. THE ZOLE RPORER�0;OLICC&10U'�.PV.AW RERRODUCTION IN RAW ORA, DO NOT SCALEDRAWING TWO PLACE DECIMAL !�)S A..OLEH0,1 I.E�.PE.0=10.OR OL;Cc NAGL_RV I��01� THREE PLACE DECIMAL -.i25 SCALE:1:3 WEIGHT:0.9564 SHEET I OF I ------------------ --- ------------- ---------------------------—---- DISCLAIMER:If any Errors,Discrepancies or Omissions appear in these drawings,specifications or other contract documents;The Owner or General Contractor shall no*the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction andfor fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them. GENERAL NOTES N.TsPv-Ps 1 2011 NEC,CITY/COUNTY FD-MARKINGS,LABELS,AND i� WARNING SIGNS • P ° °' ',�II Ii i Q REQUIRED _ I I � WARNING LABELS � A.Main Service Disconnect: ®®•po 0 0 a ® ® ®- ® `� • m m m ® C5> CAUTION p Z SOLAR ELECTRIC SYSTEM CONNECTED PLACED ON MAIN PANEL ®' 666 6 w 1.Residential buildings-the marking may be placed AT ALL•J•BOXES,COMB.BOX,DISCONNECTS DEVICE WHERE ® C4 U within the main service disconnect.The marking shall ENERGIZED,UNGROUNDED CIRCUITS MAYBE EXPOSED DURING ® co C-)o be placed on the outside cover if the main service disconnect is operable with the service panel closed. PLACED ON EACH DC DISCONNECT w Y Y Y (NVERTER#143 v co 2.Permanent labels shall be provided,no sharpie E-E marking will be allowed within any main service panel or m IJL N N N subpanel. ® m N3.All National Electric Code,and Fire Department required m - - p , �labeling will be made of sunli ht and weather-r g esrstant material.Labeling on disconnects,inverters and service panels will be pl,p�p ON MAIN PANEL made of an engraved,plastic material and be permanentlyIw-H tw- attached to its respective device.All labeling shall be attached NEAR GROUND-FAULT INDICATOR PLACED ON MAIN O W y> direto those pieces of equipment ELECTRICAL PANEL �`I p w rA cq STRING INVERTERS ONLY �__ 4.Markings:Verbiage,Format and Type of Material t° a.Verbiage: If Required:6"x 6' Placard to go on Main Service Panel ® m WARNING ® POWER TO THIS BUILDING IS ® ® t- ly ALSO SUPPLIED BY THE ® Z rn i- POTOVOLTAIC SOLAR SYSTEM, PLACED ON MAIN ELECTRICAL PANEL O' m 0 DO NOT TOUCH TERMINALS. °® • ® i m ® 1 P, rl VII, LL c y b.Format ® ® 1 0 ® ® g ' ® i ® tt® ® I 0 g F (1)White lettering on a red background. '�'I, PmIPo r�l'li. WO F F:K M (2)"PHOTOVOLTAIC BREAKER"letters to be 1/8"minimum in rn n height,All other Lettering to be 1!4"minimum in height � PLACED ON INVERTER y o (3)All letters shall be capitalized NEC-690.1 C X2) Z (4)Arial or similar font,Non-bold w 0 N d (5)Reflective weather resistant material suitable for the _ U 1- O enviroment(durable adhesive materials must meet this mw C>CO Q_U requirement) o. N a a Z O ON ALL DC CONDUITS RACEWAY EVERY 10'S•J•BOX B.Marking Requirements on AC Conduit Raceways, Enclosures,Cable Assemblies,Combiners,and w junction boxes: ( _ N v z 1. Markings:Placement,Verbiage,Format,and Type ofZ ��p ® 0 ® .® 0 0 a Material. > a.Permanent Placement Markings shall be placed Cco PLACED ON INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS, W t every 10 feet on all interior and exterior AC conduits, ENCLOSURES,CABLE ASSEMBLIES,JUNCTION BOXES,AND W m > a raceways,enclosures,and cable assemblies,at DISCONNECTS.MARIaNG SHALL BE PLACED ON INTERIOR AND W C7 0 0 turns,above and/or below penetrations,and junction boxes. EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES AND CABLE z� N ?3 b.Verbiage: CAUTION ASSEMBLIES EVERY 10 FEET(3048MM),WITHIN 1 FOOT OF TURNS Z Z z AC SOLAR VOLTAGE rn OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOFICEILING ASSEMBLIES,WALLS OR BARRIERS. C.The following label to be placed on all AC W O Z m disconnects CAUTION q,� V Z 0 w 3 t4 7?; L7 m 0 a X SOLAR CIRCUIT DISCONNECT m ® ,- m ® m b to PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH PLACED ON AC DISCONNECT W1POP-RIVETS OR SCREWS I CLAIMER:I an Errors,Discre ncies or Omissions - - Y Pa appear in these drawings speafications or other t�ntiact documents;The Owner or General Contractor shall notify the Designer,in writing,of such error or omission.In the event that the Owner or General Contractor falls to give such notice,before construction and/or fabrication of the work,the Owner or General Contractor will be held responsible to the result of any errors,discrepancies or omissions and the cost of rectifying them.