HomeMy WebLinkAboutMiscellaneous - 1360 SALEM STREET 9/24/2015 f ,AORTA 9 BOARD OF HEALTH O�tac ' tiO 120 MAIN STREET TEL. 682-6483 SS;CNUS �y NORTH ANDOVER, MASS. 01845 Ext. 32 June 26, 1992 Dr. & Mrs. John Gan 1360 Salem Street North Andover, MA 01845 Dear Dr. and Mrs. Gan: The inspection of your repaired septic system earlier today showed that all is in order. I am enclosing a brochure on preventive septic system maintenance for you to read and reference at your leisure. I most strongly advise that you have your septic tank pumped at regular intervals of approximately two to three years and that you ensure that no heavy vehicles drive over the leaching area. Sincerely, 74 1 Sandra Starr Health Inspector SLS/cjp Enclosure TOWN OFjtANDOVER SEPTIC SYSTEM SERVICING REPORT Date: A oc, 1 Homeowner: Pumper er Rco-V e Stree-- _r: � Address: �3- Phone c .. .. � 1 Phone Nature of Service: Routine Emergency Observations : Good Condition Full to Cover Baffles in Place Leachfield Runback Excessive Solids Heavy Grease Roots Other (Explain) Description of Work . Comments : i MERRIMACK ENGINEERING SERVICES, INC. PROFESSIONAL ENGINEERS 0 LAND SURVEYORS 0 PLANNERS 66 PARK STREET r ANDOVER, MASSACHUSETTS 01810 ® TEL.(508)475-3555, 373-5721 FAX(508)475-1448 j 1 i I June 18 , 1992 Town of North Andover Board of Health Town Hall Main Street North Andover , MA 01845 ATTN : Sandy Star i RE: Septic Repair 1360 Salem Street (Lot fl ) Dear Ms . Star : On June 5 , 1992 , our firm and Mr. Savage of Unit Construction Company performed a site inspection in order to determine the cause of and solution to -the failure of the subsurface sewage disposal system on the subject lot . Using a backhoe , components of the system were excavated . The distribution box was found to be filled with sludge approximately 2 inches deep in the outlet lines . This could possibly have been caused by lack of septic tank maintenance ( i . e . , annual pumping of the septic tank ) and/or malfunction ( or lack of) of the septic tank outlet: tee . Similar sludge material was found upon excavation of the end of one of the leaching trenches . Ledge was encountered during the excavation of the end of the leaching trench approximately 1 foot below the bottom of the trench . However , ledge was riot encountered at the inlet end of the trenches . Our recommendations are as follows : 1 . The septic tank should be pumped out and the outlet tee should be then inspected and , if necessary , replaced or repaired . 2 . The leaching trenches should be reconstructed in place or in the reserve area so long as any contaminated materials , soil , stone , topsoil , or subsoil , etc , is removed within ten feet of the replacement trenches . Town of North Andover, MA Homeowner: Pumper Street 0� 6 Address: Phone Phone -y� -2 Nature of Service: Routine Emergency Observations: Good Condition Full. to Cover Baffles in Place Leachfield Runback Excessive Solids Heavy Grease Roots Other (Explain) Description of Work: Comments: t ,OORTH 9 . -.. .. p BOARD OF HEALTH 120 MAIN STREET TEL. 682-6483 �9SSACMUSEt�y NORTH ANDOVER, MASS. 01845 Ext. 32 June 26, 1992 Dr. & Mrs. John Gan 1360 Salem Street North Andover, MA 01845 Dear Dr. and Mrs. Gan: The inspection of your repaired septic system earlier today showed that all is in order. I am enclosing a brochure on preventive septic system maintenance for you to read and reference at your leisure. I most strongly advise that you have your septic tank pumped at regular intervals of approximately two to three years and that you ensure that no heavy vehicles drive over the leaching area. Sincerely, Sandra Starr Health Inspector SLS/cj p Enclosure Ms . Star Page 2 June 18 , 1992 3 . The leaching trenches should be constructed 1 approximately two feet higher in elevations then the existing trenches in order to provide additional soil depth above ledge in comparison to the existing situation . Review of the Certified Foundation Plan for this site , dated March 6 , 1985 , by S. L . Giles , R . L . S. , as obtained from the Town Board of Health files shows that the existing septic tank outlet is 2 . 66 feet higher than the existing distribution box inlet , therefore allowing for the trenches to be raised without having to disrupt the septic tank . 4 . All fill to used shall be sand or gravel which meets the requirements of state and local codes . a . All applicable construction details shall be as indicated on the original construction plan for this system as prepared by Richard F . Kaminski & Associates , Inc . , dated September 26 , 1984 , which is on file with the Town Board of Heal th . Please review these recommendations and feel free to contact me if you have any questions or comments or should you require any additional information . Thank you for your consideration in this matter . Very truly yours , MERRIMACK ENGINEERING SERVICES Les Godi n Project Manager ca MERRIMACK ENGINEERING SERVICES,INC, • 66 PARK STREET • ANDOVER,MASSACHUSETTS 01810 CERT IF IED FOUNDAT ION PLAN LOCATED IN SCALE--/"= S.L.GILES R.L.S. LAWRENCE 8 NORTH ANDO�E'R rJ J od SEPrIG ;A�s 5 m S�z3(aS J 1 Rt i E oS — — 5d.cocn 'ToT — � I CERTIFY THAT THE OFFSETS SHOWN ARE FOR THE OF SC071 r' r ")FFSE TS SHOWN THE SUIL DING INSPECTOR ONL Y, b SUCH G, rd 72 `7FO,RM TO THE USE IS FOR DETERM INAT ION OF. 'ON/NG 3 Y L A W OF CONFORMITY OR NON CONFO.`?M, T Y o �]z WHEN TA KEN. 3 ` tag 0 , Board of Health �iar � 'ado r, FACE DISPOSAL D CHECK LIST` �-JA I,CT � � APPRC VED w :.d DISAPPROVED D:ATEC Providedi Reasons: "title Reg 2,a' The bmi.tted plan mast`show as a xiaunt .� a) the lot to be oerved-area,dime�nsions lot ,abutters b location and log deep observation holes-distance to ties c joc4tirn and results percolation tests-di.s ce to ties d -`dea�ign,calculations & ,calc tions showing required leaching area (( -including ease area and dimensions ,of system xistin Contours,f ► (g) location any ,t-''revs'vithin 1001 of sewage disposal system or disclaimer-check wetlands mapping (h) surface and , mirface drains witbin 1001 of sewage disposal system or .discl�eir (i) location anyx�� . .dtiago' easements within 100 a ,of seuvge disposal system or ,disclaimer.,Plannijig" hard files O known sources of water supply within 2001 of serge di.sposad. � system or disclaimer (k) location of W, proposed well to serve lot-1001 from leaching facilit; (1) location of water lines on p ty«1C' from leac,hing facility (m) location of benchmark (n) driveways (o garbage disposals _ . (p�_no-PVC-to be used in construction (q) profile of Bystem-elevatione of basement., pluimbt pipe, septic tank., distribution box inlets and outlets, distribution field piping and dither elevations (r) maAm= ground water elevation in area sewage disposal system (s) plan mast be prepared by a Professional Engineer or other professional authorized by law to prepare such, plans Reg 6 S tic Tanks (a)' cap c t es- 5D% of flown water table, tees, depth of tees, access, pumping (b) cleanout (c) lot from cellar or and g pool (d) 251 from subsurface drains Reg 103.2 Distribution Boxes (a) s pe grcatetr 0.08 Reg 10.4 (b} J bib bee Lisp t t FAIL C LeachI Pits Leaching faits are preforred where the installation is possiblo leg 11.2 s) calculations of leaching area-uinimam 500 aq . ' n.4 b) spacing 11,10 c surface drainage 2 cover material e , ,, splash pad e at elbow ') no bonds in pipe from -box to pipe � Leaching— elds leg 15.1. a no gr �aa► 2() rates/Inc . area- ft 15.4 lei construction of field 15.8 d) surface drainage 2 % Leaching Trenches Reg 14.1 � c � s- c ec - in 5X) aq ft 14.3 b dpacingA ft min 6 ft with reserve' bet ween c) diMmalonls .6 d ccnstoictic 14.7 e stone . f) surface drags UM Ica e s cue r e short "/ 1' 0 (toy bs s Rep, 9.1 , e) approval .6 ) stAnd-'y pewee i i K Health Road of s � C SISTEM North Anover s. � �)12STA.LAT1CK CHECK Zl S% LCz � ,....wa OVED DATE DISAPPrRM ED AVATICH OTC MI� I FASL OK 1. Distance Tot a. 'Wetlands - _. b. Drains c., Well 2. Water Line Location k 3. No PVC Pipe 'i 4. Septic Tank a. _'roes -_Length do To Clean Out Covers b. 'ement Pipe to Tank On Both Sides of Tank 5. Die tribution Box a. Covers & Box - No Cracks b. All Lines Flowing Equal Amounts : C. No Back Flow 6. ' Leach Field or Trench a. Dimensions b. Stone Depth c: Capped Ends d. Clean Double Washed Stone 7. Leach Pita a. Dimensions _..._ ` b. Stone Depth 4. c. calash Pads d. Tees e. Celt Pipe to Pit - Both Sides f. Clean Double Washed Stone 8. No Garbage Disposal ' 9. -M-Al Grading Inspection 10. Bau-ricading Covered System 1 11, As Built Submitted a. Lot Location b. Dimensions of System c. Location with Regard-.to Pere Test r d. Elevations e; Water Table Wat ?rshed Septic System Servicing Report Date:. Homeowner,: Pumper Stree-: Address: Phone Phone Nature oE Service: Routine 'Tez' Emergency Observations: Good Condition Full to Cover Bafflas in Place Leach Eield Runback ExcesE,ive Solids Heavy Grease Roots WC2 Other (Explain) Description of Work Comments : I i I RECEIVED COM,Monwealth of Massachusetts I / _ LOF 1 c+- ANDOVER HEALTH D acifit Information, .System Location: Address � ("14A City/Town own State Zip Code S)-stern Owner- la y. J Adress of different from location of pump) City/Town State Zip Code T elepnone Number PuM rn g co.r(j i mate of Pumping d C l - Quantity Pumped gallons Type of System_ Septic Wank Grease crap father_ (what) Systun Pumped by— Company ROOTER-MAN 46 Portland Street Lawrence, MA 01843 Location where contents were disposed:._., Signature of Hauler