Loading...
HomeMy WebLinkAboutInspection - 1770 SALEM STREET 11/5/2015 I I • North Andover Health Department community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 1770 Salem St. MAP: 106.13 LOT: 0149 INSTALLER: James Currier DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: l INSPECTIONS D-Box INSPECTION: 10/29/15 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet i Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX X Installed on stable stone base X H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) X Hydraulic cement around inlet & outlets X Observed even distribution X Speed levelers provided (not required) X Schedule 40 PVC Pipe Comments: 2 outlet pipes are not taken effluent, cannot sign COC yet. Title V inspector needs to do further inspecting. Spoke to T-V inspector Brian Murphy. He will evaluate. 11/2/15—spoke to Brian Murphy with B&D and Jim with Currier. The homeowner will take down the tree. Currier will replace the 2 pipes. Asked them both to call with results. 11/3/14—tree removed 11/4/15— Spoke to Jay Currier—2 outlet pipes were crushed because of the tree on top of them 11/5/15— D-box is taking equal distribution