PUBLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division
CERTIFICATE OF
COMPLIANCE
As of: 11/16/15
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the:
Repair of D-Box
By: Todd Bateson
At:
193 Foster Street
Map 104.D Lot 0042
GNorth Andover, MA 01845
Th Issuance of this certificate shall not,be construed as a guarantee that the system will function satisfactorily.
Achele-Grant �....
Public Health Agent
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fox 978.688.8476 Web www.townofnorthandover.com
1
i
l
J
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 193 Foster St. MAP: 104.D LOT: 0042
INSTALLER: Todd Bateson
DESIGNER:
PLAN DATE:
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
D-Box INSPECTION: 11/16/15
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
i
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
F-1 Weep hole plugged
❑ 1500 gallon Pump Chamber installed
F-1 H-10 loading
F-1 Monolithic tank construction
F-1 Inlet tee installed, centered under access port
[:1 Pump(s) installed on stable base
F-1 Alarm float working
❑ Pump On/Off floats working
F-1 Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
E:1 Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
F-1 Alarm sounds when float is tripped
❑ Location of control panel: basement
F-1 Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
X Installed on stable stone base
X H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
X Hydraulic cement around inlet & outlets
X Observed even distribution
X Speed levelers provided (not required)
X Schedule 40 PVC Pipe
Comments: replaced cover on tank