Loading...
HomeMy WebLinkAboutCertificate of Compliance - 193 FOSTER STREET 11/16/2015 r � r L • t 1 i i PUBLIC HEALTH DEPARTMENT Town of North Andover Community Development Division CERTIFICATE OF COMPLIANCE As of: 11/16/15 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of D-Box By: Todd Bateson At: 193 Foster Street Map 104.D Lot 0042 GNorth Andover, MA 01845 Th Issuance of this certificate shall not,be construed as a guarantee that the system will function satisfactorily. Achele-Grant �.... Public Health Agent 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fox 978.688.8476 Web www.townofnorthandover.com 1 i l J North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 193 Foster St. MAP: 104.D LOT: 0042 INSTALLER: Todd Bateson DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS D-Box INSPECTION: 11/16/15 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port i ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base F-1 Weep hole plugged ❑ 1500 gallon Pump Chamber installed F-1 H-10 loading F-1 Monolithic tank construction F-1 Inlet tee installed, centered under access port [:1 Pump(s) installed on stable base F-1 Alarm float working ❑ Pump On/Off floats working F-1 Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing E:1 Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits F-1 Alarm sounds when float is tripped ❑ Location of control panel: basement F-1 Alarm signal located inside: basement Comments: DISTRIBUTION-BOX X Installed on stable stone base X H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) X Hydraulic cement around inlet & outlets X Observed even distribution X Speed levelers provided (not required) X Schedule 40 PVC Pipe Comments: replaced cover on tank