HomeMy WebLinkAboutMiscellaneous - 64 FOREST STREET 11/18/2015 i
•
r
1
.PUBLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division
CE-xT-"'h TIFICATE OF
COMPLIANCE
As of® 11/18/15
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the:
Complete Repair
On-Site Sewage Disposal
By: Todd Bateson
At:
64 Forest Street
Map 106A Lot 6
" , ,North
e Issu ce of tl�s ce tiftc to sha it not be construed as a guarantee that the system will function satisfactorily.
oV
J
--�
is ele Grant---
Public Health Agent
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.tomohorthandover.com
I
f
• I�,���IE,, I� r°,�iln ,i��f����luh�
i
1
i
PUBLIC HEALTH DEPAUTMEN'r
(opirrnunitp Developmnt Uivisiora
TOWN OF NORTH ANDOVER
SEPTIC DISPOSAL SYSTEM—INSTALLATION CERTIFICATION
The undersigned hereby certify that the Sewage Disposal System(instructed;( )repaired;
By: 169 „2_ : 'T F,
(Prinn-t^^Name)
Located at (fl
(Installation Address)
Was installed in conformance with the North Andover Board of Health approved plan,originally dated
and last revised on with a design flow of
gallons per day. The materials used were in conformance with those specified on the
approved plan;the system was installed in accordance with the provisions of 310.CMR 15.000,Title 5 and local
regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on
the As-built which has been submitted to the Board of Health.
Bottom of Bed Inspection Dater _ „ �,
Engineer Representati a(Signature)
1 ' U1
And—Print Name
Final Construction Inspection Date:
Engineer Representative(Signature)
And—Print Name
Installer:
����, � gnature) Date:
And—Print Name
Engineer:_ c 444V441,_(Signature) Date: ////Z////S-
/ /S. -
And—Print Name
1600 Osgood Street, North Andover, Massachusetts 01845
Phone 978.688.9540 Fox 9784688.8476 Web http://www.townofnorthandover.com
P
o
Town of North Andover — Septic rte - AS-BUILT CHECKLIST
1) V All changes to the design plan have been reflected and noted on the as-built plan
2) 7As-built plan has a suitable scale; (1 inch = 40 feet or fewer for plot plans)
3) Street Address,Assessor's Map and Lot Number
4) Lot Lines and Location of Dwellings served by the system
5) Locations,Elevations and Dimensions of As-built system components,including reserve (if applicable)
6) 7 Ties to all tank openings,d-box,and leach area from dwelling or Permanent Structure
' Setback distances are shown on the as-built plan from system components to:
Subsurface,interceptor&foundation drains
Catch basins
0 Property lines
Dwellings or other structures
Private water supply or irrigation wells
Watercourses or wetlands
0) Locations of Wells,Drains,Wetland Resource Areas within 150 feet of system
9) � '�Location of water,gas,electric lines,cable,controll.panel (if applicable) (
10) Location of Structures within 6 Inches of Finished Grade
11) Original Stamp&Signature
12) ocation and holder of any easements which could impact the system
13) V Impervious Areas;Driveways,etc
14) �North Arrow
TLocation 15) &Elevation of Benchmark used
16) STATEMENT ON PLAN (NA 5.3)
a. "I certify the locations, elevations, ties, cover material;exposed component covers etc.,
shown on this as-built SllbStantially agree with the approved plan and have determined that the
break out elevations,if applicable,have been met."
Signature of Designer Date
b. "If a STUCTURAL WALL IS PRESENT(NA 4.9)a Letter or statement on the as--built indicating
the wall- was,or was not,constructed in accordance with the intended design and any
manufacturer's specifications."
Signature of Designer Date
C
As of:Tuesday,November 17,2015
i
1
1
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 64 Forest Street MAP: 106A LOT: 6
INSTALLER: Todd Bateson
DESIGNER: Merrimack Engineering
PLAN DATE: 615/15, rev. 6/25/15
BOH APPROVAL DATE ON PLAN: 06/30/2015
INSPECTIONS
TANK INSPECTION: 9/9/15
DATE OF BED BOTTOM INSPECTION:9/9/15
DATE OF FINAL CONSTRUCTION INSPECTION: 9/11/15
DATE OF FINAL GRADE INSPECTION:10/27/15
SITE CONDITIONS
N/A Contractor reports any changes to design plan
® Existing septic tank properly abandoned
® Internal plumbing all to one building sewer
® Topography not appreciably altered
Comments:
SEPTIC TANK
® Building sewer in continuous grade, on
compacted firm base
N/A Cleanouts per plan
® Bottom of tank hole has 6" stone base
® Weep hole plugged
® 1500 gallon tank has been installed
H-10 loading
® Monolithic tank construction
®
Watertightness of tank has been achieved by
visual testing
® Inlet tee installed, centered under access port
1
® Outlet tee installed, centered under access port
(gas baffle/effluent filter)
® 24" inch cover to within 6" of finish grade
installed over one access port
® Neoprene boots around inlet & outlet
Comments:
DISTRIBUTION-BOX
® Installed on stable stone base
® H-20 D-Box
N/A Inlet tee (if pumped or >0.08'/foot)
® Hydraulic cement around inlet & outlets
® Observed even distribution
® Speed levelers provided (not required)
® Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTEM (General)
® Bottom of SAS excavated down to C soil layer,
as provided on plan
® Size of SAS excavated as per plan
® Title 5 sand installed, if specified on plan
N/A 40 Mil HDPE barrier installed
® Laterals installed and ends connected to
header (and vented if impervious material
above)
® Elevations of laterals and chambers installed as on
approved plan
N/A Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments:
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
® Brand and Model of Chamber: Low Profile
Standard Quick 4 Infiltrator Chambers
® Number of chambers per row: 10
® Number of rows (trenches): 4
i
i
Comments: Total Chambers = 40
i
FINAL GRADE
X Loamed
X Seeded
X Cover per plan
Comments:
DOCUMENTS NEEDED
X Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
X As-Built Plan
i
i
BM = 164.90
HR = 2.55
HI = 167.45
i
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Existing Building Sewer 5.46 161.74 162.0
OUT
Septic Tank IN 5.62 161.48 161.40
Septic Tank OUT 5.98 161.12 161.15
Distribution Box IN 6.10 161.00 161.00
Distribution Box OUT 6.27 160.83 160.83
Lateral 1 TOP 6.34
Lateral 1 INVERT 160.76 160.78
Lateral 2 TOP 6.32
Lateral 2 INVERT 160.78 160.78
Lateral 3 TOP 6.32
Lateral 3 INVERT 160.78 160.78
Lateral 4 TOP 6.32
Lateral 4 INVERT 160.78 160.78
Top of Chamber 6.30 161.15 161.17
Bottom of Bed/Chamber 160.48 160.50
i
1
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 10 10 --
® Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck, on footings, etc 5 10 --
® Waterline 10 10 101
® Private drinking well 75 1002 50
® Irrigation well 75 100
® Surface Water 25 50
® Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
® Trib. to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot. Area
® Reservoirs 400 400
® Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
® Drains (Other)Foundation 10(5) 20(1.0)
® Drywells 20 25
1 Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws