HomeMy WebLinkAboutMiscellaneous - 45 BRIDGES LANE 11/13/2015 i i j 44 Commercial Street Raynham,MA 02767 Tel: (508)880-0233 Fax: (508)880-7232 November 13, 2015 North Andover Board of Health 1600 Osgood Street North Andover,MA 01 845 Attention: Health Agent Reference: FAST° Wastewater Treatment System- Serial Number: 24751 Attached please find the Field Inspection& Service Michael with field test r at 45 BridgesrLane, services performed on 10/4/15 at the property of Mi North Andover,MA. Please call if you have any questions or require additional information. Sincerely, Wastewater Treatment Services, Inc. Service Department Enclosures Copy to: Michael Fox Massachusetts DEP J f 3 N OAR ?�R R A T E d 8450 Cole Parkway, Shawnee, KS 66227, Phone 913-422-0707, Fax 913-422-0808 e-mail:onsite(aDbiomicrobics.com, www.biomicrobics.com, 800-753-FAST(3278) FIELD INSPECTION & SERVICE REPORT For Bio-Microbics Single Home FAST°System 24510 INSTALLATION AUTHORIZED SERVICE PROVIDER Installation Address: 45 Bridges Lane Name:Wastewater Treatment Services,Inc. North Andover,MA 01845 Owner Name:Michael Fox Mail Address: 45 Bridges Lane Mail Address: 44 Commercial Street North Andover,MA 01845 Raynham,MA 02767 Phone: Fax: e-mail: Phone:(508)880-0233 Fax:(508)880-7232 e-mail: INSTALLATION INFORMATION Model No. Serial No. Date of Installation Date of last pump out MicroFAST.5 24751 5/17/2005 3-11-13 EQUIPMENT YES NO MAINTENANCE PERFORMED AND COMMENTS Electrical Panel(s) Visual Alarm Operating x Audio Alarm Operating x (if present) Blower(s) Air Inlet Filter Clean x Blower Hood Vents Clear x Excessive Noise x Excessive Vibration x Treatment unit(s) Unusual Odor x Pumpout Required x Primary Settling Zone 4» Aerobic Treatment Zone 4" EFFLUENT(optional) LIMIT RESULT Estimated Daily Flow 440 gpd pH(Standard Units) 7.2 Color Clear Temperature 64 Degrees F Odor Moldy Comments:Distal Pressure Reading:DPR#1: 12",DPR#2:12",DPR#3:6",DPR44:6",DPR#5:6" TECHNICIAN SERVICE DATE Michael Foisy 10/4/15 Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/ Treatment and Disposal Systems 24510 A. Installation Michael Fox Owner 45 Bridges Lane Facility Street Address North Andover 01845 City Zip Mailing address of owner, if different: 45 Bridges Lane Street Address/PO Box: North Andover MA 01845 City State Zip Telephone Number B. Authorized Service Provider Wastewater Treatment Services Inc. O&M Firm 44 Commercial Street Street Address Raynham MA 02767 City State Zip 508-880-0233 Telephone Number Michael Foist' 2762 Certified Operator Name Certification Number C. Facility/System Information 24751 Bio-Microbics Inc. MicroFAST .5 DEP ID Manufacturer ID Model Number 5/1712005 5/17/2005 Installation Date Start of Operation Approval Type: [] General [] Provisional [] Piloting [x] Remedial [] General Denite Seasonal Residence—used less than 6 mo./year: []Yes [x] No D. Operating Information 10/4/15 Inspection Date Previous Inspection Date 4" Pumping Recommended []Yes [x] No Sludge Depth(to be checked yearly) 1 Massachusetts Department of Environmental Protection LlBureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/ Treatment and Disposal Systems 24510 E. Field Tesin Field Inspection: Color: []gray [) brown [x]clear []turbid [] Other(specify): Odor: [] musty [] earthy [x] moldy [] offensive [] turbid Effluent Solids: [x] no [1 some pH 7.2 S DO 3.8 mg/L Turbidity 2.66 NTU 6 to 9 2 or greater 40 or less Should a Remedial or General Use system fail the Field Testing, effluent samples shall be collected per Standard Methods and analyzed for BOD and TSS. F. Sampling Information Samples Taken: [] Influent [] Effluent Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use nitrogen reducing systems: 440 gpd Parameters sampled: Influent: [] pH [] BOD [] CBOD []TSS []TKN [] Nitrate [] Nitrite [] Phosphorus [] Spec. Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform Effluent. [] pH [] BOD [] CBOD []TSS []TKN [] Nitrate [] Nitrite [ ] Phosphorus []Spec. Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [) Fecal Coliform G. Inspection and Maintenance Description of any maintenance performed since previous inspection & during this inspection: Cleaned Filter Checked Splash Recycle Pump(s) Inspected Float(s) Inspected Notes and Comments: Distal Pressure Reading: DPR#1: 12" DPR#2: 12" DPR#3: 6" DPR#4: 6", DPR#5: 6" 2 Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 P Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 24510 H. Certification I certify: I have inspected the sewage treatment and disposal system at the address above, have conducted the required Field Testing and/or sample collection in accordance with Standard Methods, have completed this report and the attached technology operation and maintenance checklist, and the information reported is true, accurate, and complete as of the time of the inspection. I am a Massachusetts certified operator in accordance with 257 CMR 2.00. 10/4/15 Operator Signature Date System owner must submit this report, technology O&M checklist, and any required sampling results to the local board of health and DEP as follows for each inspection performed: Remedial Use—by January 31st of each year for the previous calendar year Piloting Use -within 45 days of inspection date Provisional Use—by March 31 th of each year for the previous 12 months General Use—by September 30th of each year for the previous 12 months Send to: Department of Environmental Protection Attention: Title 5 Program One Winter Street, 6th Floor Boston, MA 02108 3