HomeMy WebLinkAboutCertificate of Compliance - 554 FOSTER STREET 6/10/2013 ..TCC+d
PUBLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division ,.
CERTIFICATE OF
COMPLIANCE
As o£ 6/10/1.3
This is to certify that the individual subsurface disposal system has been installed in accordance
with the provisions of Title 5 of the State Environmental Code:
Complete Repair and Construction of an
On-Site Sewage Disposal System
By: James Kellett
At:
554 Foster Street
Map 104B Lot 0005
North Andover,MA 01845
The lssuan�f this certificate shall not be construed as a guarantee that the system will function satisfactorily.
�7
Yubhc He Y L//z
sat Saw
Ith A ent
16000sgood Street,North Andover,Mnssudmsens 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.townolnorthnndover.rone
r
PUBLIC HEAUll DEPARIMM '..
(ammunity Developa"'n N3i"n
TOWN OF NORTH ANDOVER
SEPTIC DISPOSAL SYSTEM-INSTALLATION CERTIEISATIO RECE1,V D
The undersigned hereby certify that the Sewage Disposal System(✓)cons.d;()re fired; F i
dC.f�
By:_.. .� V —�I.... ._.. .._. 70WN OY•PdG07'fIi AN(70VEPo
(Print Name) MEALI'41 DFFAI2T'MEN7'
Located at: k�-'l.E FYI ar
(Instailednn Address)
Was installed in conformance with the North Andover Board of Health approved plan,originally dated
I- 2 and last revised on l"e C I,` with a design flow of
gallons per day.The materials used were in conformance with those specified on the
approved plan;the system was installed in accordance with the provisions of 310.CMB 15.000,Title 5 and local
regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on p
the As-built which has been submitted to the Board ofHealth,-korM
Bottomof Bedlnspection Date::___�t,'1 '-'>2 ,__
Engineer Reprter6trve(Signature)
And-Print Name
Final Construction Inspection Date:_-2 1 41 �d �
Engineer Represen tive(Signature)
k�w (i�n�E1,t�
And-Print Name
Installer: (Signature) Date:..5 !
A d Pr N
am ame
Ertgmer: U/Jle'*f (sigora) Data:
o��
And-Print Name
8600 Osgood Street,North Andover,Massoc4eumms 01645
Phone:976.646.9540 Fax 976.6$4.0476 Wab htrp:/(www.tnwnofnorthnndover.rmn
1 Il r—:1( l
C �M
May 23,2013 19i'i %i%f111
r(,7VVN Cu IdC)42Fpi FaNI']C7V�;;fd
North Andover Board of Health
North.Andover,MA
Re: 554 Foster Street
Dear Susan:
I am writing to you to explain the reason for the septic tank being installed three feet into the 50
foot buffer zone instead of as planned at 52 feet away from wetland flags. As being a longtime
licensed septic installer in the Town of North Andover,the Board of Health requires that a
building sewer pipe from the house be completely straight without any bends. Therefore,when
we uncovered the building sewer pipe,we found that it came out at an angle not as planned. We
had to make a field change by turning the tank to accept the building sewer pipe to an inlet on the
tank. While we were installing this,we were obtaining severe ground water and collapsing soil
due to the high water table.It became so bad that we were nervous about undermining the
existing foundation and stairs at the back of the house. Michelle Grant,the N.Andover Health
Inspector,was present during this situation and witnessed this unmanageable situation.After
taking ties to the property line,the foundation and existing wetland flags placed in the ground,
we were all within setbacks set by the code and plan. It has come to my attention after the septic
as-built was completed;Merrimac Engineering explained to me that the tank was inside the 50
foot buffer zone. I explained to them that we measured from the flags in the ground and were
out of the buffer zone. Ile then explained to me that there was a new delineation line for the
wetlands that never got staked out. As you can see,this was a very simple mistake on my part
and I am looking for help to solve this matter any way away from moving the tank due to the
unstable soil we ran into setting the tank originally.
I am looking for the committee to understand this simple mistake and hope this can be taken care
of by a simple variance on the plan.1 holy appreciate your attention to this matter.
Best regards,
'm"K,llett
North Andover Health Department
Community Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 554 Foster St. MAP:1048 LOT:5
INSTALLER:Jim Kellett
DESIGNER: Vladimir Nemchenok
PLAN DATE: 1118/12
BOH APPROVAL DATE ON PLAN:12/18/12
INSPECTIONS
TANK INSPECTION:
DATE OF BED BOTTOM INSPECTION:4/18/13
DATE OF FINAL CONSTRUCTION INSPECTION:4/25/13
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
• Contractor reports any changes to design plan
• Existing septic tank properly abandoned
• Internal plumbing all to one building sewer
• Topography not appreciably altered
Comments:Re-routed plumbing internally instead of externally as shown on
design plan.This is a better option.
Old dug well collapsed and backfilled during the construction. The well was
previously abandoned.
SEPTIC TANK
® Building sewer in continuous grade,on
compacted firm base
N/A Cleanouts per plan
® Bottom of tank hole has 12"stone base
® Weep hole plugged
® 2000 gallon tank has been installed
H-10 loading
® Monolithic tank construction
®
Watertightness of tank has been achieved by
visual testing
® Inlet tee installed,centered under access port
® Outlet tee installed,centered under access port
(effluent filter)
® 20"inch cover to finish grade installed over
middle and outlet access ports
® Hydraulic cement around inlet&outlet
Comments:Septic/Pump combo tank '...
PUMPCHAMBER
❑ Bottom of tank hole has 6"stone base
® Weep hole plugged
® 2000 gallon Septic/Pump Combo installed
® H-10 loading j
❑ Monolithic tank construction
® Inlet tee installed,centered under access port
® Pump(s)installed on stable base
® Alarm float working
® Pump On/Off floats working
® Separate on/off floats
® Drain hole in pressure line
® 20"cover at final grade installed over pump
access port
® Water tightness of tank has been achieved by
Visual testing
® Hydraulic cement around inlet&outlet
Comments:
CONTROL PANEL
® Alarm&Pump are on separate circuits
® Alarm sounds when float is tripped
® Location of control panel:basement
® Alarm signal located inside:basement
Comments:
DISTRIBUTION-BOX
® Installed on stable stone base
® H-20 D-Box
N/A Inlet tee(if pumped or>0.087foot)
® Hydraulic cement around inlet&outlets
® Observed even distribution
N/A Speed levelers provided(not required)
Comments:Baffle D-Box installed,2"x 4"coupling installed 4'before D-Box for
velocity reduction
SOIL ABSORPTION SYSTEM(General)
® Bottom of SAS excavated down to C soil layer,
as provided on plan
® Size of SAS excavated as per plan
® Title 5 sand installed,if specified on plan
® 40 Mil HDPE barrier installed
® Laterals installed and ends connected to
header(and vented if impervious material
above)
® Elevations of laterals and chambers installed as on
approved plan
N/ Retaining wall(boulder/concrete/timber/block)
Final cover as per plan
Comments:
SOIL ABSORPTION SYSTEM(Gravel-less Chambers)
® Brand and Model of Chamber:Standard Quick
Low Profile 4 Infiltrator Chambers
® Number of chambers per row:6
® Number of rows(trenches):5
Comments:Total Chambers=30
i
BM=100.00
HR= 0.68
HI = 100.68
SYSTEM ELEVATIONS
ROD AS- LT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark 0.68 100.00
Building Sewer OUT 7.04 93.29 95.6 _
Septic Tank IN 7.23 93.10 93.00
(2„)Septic Tank OUT 7.65 92.86 92.75
Distribution Box IN 4.08 96.25 96.20 '
Distribution Box OUT 4.21 96.12 96.03
Lateral 1 TOP 4.33
Lateral INVERT 96.00 95.98
Lateral 2 TOP 4.33
Lateral21NVERT 96.00 95.98
Lateral 3 TOP 4.33
Lateral3INVERT 96.00 95.98
Lateral 4 TOP 4.33
Lateral 4 INVERT 96.00 95.98
Lateral 5 TOP 4.33
Latera151NVERT 96.00 95.98
Top of Chamber 4.33 96.35 96.37
Bottom of Bed/Chamber 95.68 95.70
i
I
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 10 10 --
® Cellar wall 10 20 --
® inground pool 10 20 --
® Slab foundation 10 10 --
® Deck,on footings,etc 5 10 --
® Waterline 10 10 10'
® Private drinking well 75 too, 50
® Irrigation well 75 100
® Surface Water 25 50
❑ Bordering Vegetated Wetland, '
Salt Marsh,Inland/Coastal Banks 75 100*As approved by BOI I&
Con Co.
® Wetlands bordering surface
water supply or trib.(in Watershed) 150 150
® Trib.to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot.Area
® Reservoirs 400 400
® Drains(wat.supply/trib.) 50 100
® Drains(intercept g.w.) 25 50
® Drains(Other)Foundation 10(5) 20(10)
® Drywells 20 25
I
Suction lido 222(2)
s 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
'A,defied in 310 CMR 10.55,10.32,10.54,and 10.30,respectively,pursuant to 15.217(3),also by NA
wetland bylaws
.�i
/.
f'
�� ���
� t'i 1 i
r
�1 ,/ � /
�a�,�
���'��°�'�F �;i �l
rii P 'i
���/ � � 9
��N ;� � ��D �� � __
� �r)� l,�i�jp
of ry�p,. � y�*�f��
��� �`���.� t���r�Y � � ��i
r i�
i
i � a lye
�,'!I k� ���i� ! l'0'�. i� �'.
� ���" u���� ANN, a �'
�G�Y ���� �d /� '�Y M "TAY
% L/��"�rr �I�ded�ri���i�//,� II � N0� �11M � �1
y� ���. �� ,r�G ' _.1
�' r
"ppp �� /8 4 �"
� G L_I
1 p��o f/���'I� I �� J�f ��Yd�/ �1
F / �1 Fta �
� 1,'�✓� � ��f ��%� J E
��/p�f� Ire �r� 9i�, e1 daJi
��rl� �� e�ae �,, 'e�r»���iriiiu�fe �'.
���C'h �i , �y� � - r.
r
Ar� ar� ,� y � i
� �
��r�'d+tdr � ,
�� �� � 1i
r
0 �a� r
I
id k�� n r�„����r
�:; ,��
r�-
�✓��� "�iau��9 u� 'I
�f 6 f i �'ri ���t J
i I � t �id
I�,
FYI