HomeMy WebLinkAboutCertificate of Compliance - 81 BRADFORD STREET 12/10/2015 i
l
r
PUBLIC HEALTH DEPARTMENT
Town of Forth Andover
Community Development Division
CERTIFICATE u"F
-- COMPLIANCE
A of.- 12/10/15
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the:
Complete i
On-Site Sewage Disposal System
y® Todd Bateson
At:
81 Bradford Street
Map 61 Lot 37
)t
Andover, MA 01845
The, ss6ance of this certificate sial1�not be 7nstrued as a guarantee that the system will function satisfactorily.
f
Michele Grant
Public Health Agent
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.6889540 Fax 978.688.8476 Web www,townofnortliandover.com
i
I
•
North Andover Health Department
fommunity and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 81 Bradford St. MAP: 61 LOT: 37
INSTALLER: Todd Bateson
DESIGNER: Christiansen & Sergi
PLAN DATE: 10/26/15, REV 11/6/15
BOH APPROVAL DATE ON PLAN: 11/11/15
INSPECTIONS
TANK INSPECTION: 11/23/15
DATE OF BED BOTTOM INSPECTION: 11/24/15
DATE OF FINAL CONSTRUCTION INSPECTION: 12/1/15
DATE OF FINAL GRADE INSPECTION: ,r
SITE CONDITIONS
N/A Contractor reports any changes to design plan
® Existing septic tank properly abandoned
® Internal plumbing all to one building sewer
• Topography not appreciably altered
Comments:
SEPTIC TANK
• Building sewer in continuous grade, on
compacted firm base
N/A Cleanouts per plan
® Bottom of tank hole has 6" stone base
® Weep hole plugged
® 1500 gallon tank has been installed
H-10 loading
® Monolithic tank construction
® Water tightness of tank has been achieved by
visual testing
® Inlet tee installed, centered under access port
Z Outlet tee installed, centered under access port
(gas baffle)
Z 24" inch cover to within 6" of finish grade
installed over one access port
Z Neoprene boots around inlet & outlet
Comments:
DISTRIBUTION-BOX
Z installed on stable stone base
Z H-20 D-Box
N/A Inlet tee (if pumped or >0.08'/foot)
Z Hydraulic cement around inlet & outlets
Z Observed even distribution
Z Speed levelers; provided (not required)
Z Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTEM (General)
Z Bottom of SAS excavated down to C soil layer,
as provided on plan
Z Size of SAS excavated as per plan
Z Title 5 sand installed, if specified on plan
Z 40 Mil HIDPE barrier installed
Z Laterals installed and ends connected to
header (and vented if impervious material
above)
Z Elevations of laterals and chambers installed as on
approved plan
N/A Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments: 37 Y21- x 32 W, depth 60"
FINAL GRADE
Loamed
Seeded
F-A Cover per plan
i
i
l
Comments:
i
DOQUMENTS NEEDED
u
Certification of Installation Form submitted
y engineer and signed and dated by
Engineer and installer
As-Built Plan
i
BM = 100-00
HR = 9.10
HI = 109.10
SYSTEM ELEVATIONS
ROD AS-IBLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark -
Building Sewer OUT 6.10 102.65 101.85
Septic Tank IN 6.99 101.76 101.65
Septic Tank OUT 7.29 101.46 101.40
-'
Distribution Box IN 7.53 101.22 101.20
Distribution Box OUT 7.70 101.05 101.03
Lateral 1 TOP 7.76 / 7.90
Lateral 1 INVERT 100.99 / 100.85 100.98 / 100.85
Lateral 2 TOP 7.76 / 7.90 100.98 / 100.85 100.99 / 100.85
Lateral 2 INVERT -
Lateral 3 TOP 7.76 / 7.90 100.99 / 1 100.98 / 100.85
Lateral 3 INVERT -
Lateral 4 TOP 7.76 / 7-.9-0
Lateral 4 INVERT 100.99 / 100.85 100.98 / 100.85
Lateral 5 TOP 7.76 / 7.90
Lateral 5 INVERT 100.99 / 100.85 100.98 / 100.85
Top of Chamber
Bottom of Bed.L-- 8.76 100.34 100.5
1
i
i
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
i
Tank SAS Sewer t
® Property line 10 10 --
M Cellar wall 10 20 --
M Inground pool 10 20 --
M Slab foundation 10 10 --
M Deck, on footings, etc 5 10 --
M Waterline 10 10 101
M Private drinking well 75 1002 50
M Irrigation well 75 100
M Surface Water 25 50
M Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
M Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
M Trib. to surface water supply 325 325
M Public well 400 400
M Interim Wellhead Prot. Area
M Reservoirs 400 400
M Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
M Drains (Other)Foundation 10(5) 20(10)
M Drywells 20 25
I
r Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws
1
1
1
i
1
PUBLIC HEALTH DEPARTMENT RECEIVED
Community Development Division
TOWN OF NORTH ANDOVER
SEPTIC DISPOSAL SYSTEM—INSTALLATION CERTIFICATION �������������
The undersigned hereby certify that the Sewage Disposal System( )constructed; ,repaired;
(Print Name)
Located at: / /° -C)f-6 1> <'S%ff'C°
(Installation Address)
Was installed in conformance with the North Andover Board of Health approved plan, originally dated
and last revised on x/16 12 V-.,5 ry with a design flow of
gallons per day. The materials used were in conformance with those specified on the
approved plan;the system was installed in accordance with the provisions of 310. CMR 15.000,Title 5 and local
regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on
the As-built which has been submitted to the Board of Health.
Bottom of Bed Inspection Date: ? /
Engineer RepOntative(Signture)
And—Print Name
Final Construction Inspection Date:
Engineer Representative(Signature)
And—Print Name
Installer: �-Y J g nature f w_
) Date•
r°
And—Print Name
Engines , =; ignature) Date: rlF> l
f ..,.
And—Print Name
1600 Osgood Street, North Andover, Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web http://www.townofnorthandover.coni
Town of North Andover — Septi
Lc System - AS-BUILT CLIECKLIST
1) Al)changes to the design plan have been reflected and noted on the as-built plan
2) As-built plan has a suitable scale; (1 inch = 40 feet or fewer for plot plans)
3) Street Address,Assessor's Map and Lot Number
4) Ipt Lines and Location of Dwellings served by the system
5) —Locations,Elevations and Dimensions of As-built system components,including reserve (if applicable)
6) """Ties to all tank openings,d-box,and leach area from dwelling or Permanent Structure
—Setback distances are shown on the as-built plan from system components to:
Subsurface,interceptor&foundation drains
Catch basins
Property lines
AD e '�gs or 0 other struc
ur es
Private water supply or irrigation wells
Watercourses or wetlands
8) 1 LLocations of Wells,Drains,Wetland Resource Areas within 150 feet of system
9) LLocation of water,gas,electric lines,cable,control panel (if applicable)
10) Location of Structures within 6 Inches of Finished Grade
11) —Loriginal Stamp&Signature
12) �N Location and holder of any easements which could impact the system
13) impervious Areas;Driveways,etc
14) _�Z_North Arrow
I Location &Elevation of Benchmark used
16) STATEMENT ON PLAN (NA 5.3)
3. "1 certify the locations,elevations, ties,cover material;exposed component covers etc.,
shown on this as-built substantially agree with the approved plan and have determined that the
break out elevations,if applicable,have been met.
Signature of Designer Date
b. "If a STUCTURAL WALL IS PRESENT(NA 4.9)a Letter or statement on the as-built indicating
the wall- was or was not constructed in accordance with the intended design and an
manufacturer's specifications."
Signature of Designer Date
As of:Thursday,December 10,2015