HomeMy WebLinkAboutBuilding Permit # 11/17/2015 o�BUILDING PERMIT NORTH BUILDING
OF NORTH ANDOVER �2 y� ,
APPLICATION FOR PLAN EXAMINATION
Permit No#: 0 I Date Received �y A�RATEU PPa��y
SSACHLis
Date Issued:
I PORTANT: Applicant must complete all items on this page
LOCATION �� '(DCL ad()G(C Ln
Pri t
PROPERTY OWNER �J t'C ! H/) I�irn a ST"
Print 100 Year Structure yes o
MAP 0-1.12 PARCEL:0 000-7 ZONING DISTRICT:_ Historic District yes no
Machine Shop Village yes o
TYPE OF IMPROVEMENT PROPOSED USE
Residential Non- Residential
❑ New Building ane family
11 Addition ❑Two or more family [I Industrial
P(Alteration No. of units: El Commercial
❑ Repair, replacement ❑Assessory Bldg ❑ Others:
❑ Demolition ❑ Other
F1, 46
Me
����v" �✓ershed�stnct
,e ewes
�,�s .
gw . mx ..,. .�
DESCRIPTION OF WORK TO BE PERFORMED:
ins-J-a 11 ?'Z 5(5lar P.1 c %�nj,?,(s faFe-cl. a-k S, -2Z 6Lk� cm.k
d '0f,, 5�;1 kr�w�,e � ke in,!-��cvn��cf�egr w`��hae- h0M /tel-�c�/
Identification- Please Type or Print Clearly
OWNER: Name: �Od i i-h k-noS Phone: 9� - 79�1- 6,s�
Address: (Pac(doGlc Lit Uo4h g\m MQ r 01�-L'
Contractor Name: A0Y-G('4 Phone:
Email: gb�anC0 0-1 - ar � o Corn
Address: 9-00 LU1(mi k�n 'Wra 6k!R`7
Supervisor's Construction License: (p U- Exp. Date:
Horne Improvement License: S 2 Exp. Date:
ARCHITECT/ENGINEER Phone:
Address: Reg. No.
FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125,00 PER S.F.
Total Project Cost: $ 1 � , O0 U FEE: $ 1 W
Check No.: Receipt No.: p01 Cc OC'
NOTE: Persons contracting with unregistered contractors do not have access to the guaranty fund
r - -
..
Version#52.3-TBD
SolarCity
PYL
October 20, 2015 �t
RE: CERTIFICATION LETTER
JASON��IL I/��C'�j
IM
Project/Job # 0182914 -
t���u
Project Address: Arnost Residence
29 Paddock Ln r} STRUCTURAL E1�
North Andover, MA 01845
IS T
Design Criteria: i thJe on Toman
Date: 3:54:49-07'00'
-Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05, and 2005 NDS
- Risk Category = II
-Wind Speed = 100 mph, Exposure Category C
-Ground Snow Load = 50 psf
- MP1: Roof DL = 10.5 psf, Roof LL/SL = 35 psf(Non-PV Areas), Roof LL/SL = 35 psf(PV Areas)
Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.33365 < 0.4g and Seismic Design Category(SDC) = C < D
To Whom It May Concern,
A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity.
Structural evaluation was based on site observations and the design criteria listed above.
Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading
indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions
adopted/referenced above. This review relies on the roof's structural system having been originally designed and constructed in
accordance with the building code requirements and having been maintained to be in good condition.
Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the
manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading.
The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural
review is provided in the results summary tables on the following page.
Jason W. Toman, P.E.
Professional Engineer
T: 480-553-8115 x58115
email: jtoman@solarcity.com
t.:i<:,3I - ' ftl j' i3t1 Mateo, A 1.1<.j 0 , r `.(� �,.'�.ti- r?<. I't` F(650)0) is 1t; i.l)',.' .?iii CY.t :a l'
Version#52.3-TF :)
PIL
SolarCity
HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES
Landscape "Hardware-Landscape Modules'Standoff Specifications
Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR
MPi 64" 22" 39" NA 64 62.4%
Portrait Hardware-Portrait Modules'Standoff Specifications
Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR
MPI 32" 14" 65" NA Staggered 51.9%
Structure Mounting Plane Framing Qualification Results
Type Spacing Pitch Member Evaluation Results
MPi Stick Frame @ 16 in. O.C. 280 Member Analysis OK
Refer to the submitted drawings for details of information collected during a site survey on. All member analysis and/or evaluation is based on framing information
gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC.
f!,,, C:ieai JC_..ti „i i ori`i 'i t,.,c.. r? <i fii 2 rj„�_;._ .., 1 t' F 1(,,50) ,,,(,(t y I1.
�
STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MPI
MemberProperties Summary
MPI Horizontal Member:Spans Rafter Properties
Overhang 0.99 ft Actual W 1.50"
Roof System Properties Span 1 13.69 ft Actual D 7.25"
Number of Spans w/o Overhang) 1 Span 2 Nominal Yes
Roofing Material Comp Roof San 3 A 10.88 in.^2
Re-Roof No Span 4 SX 13.14 in.^3
Plywood Sheathing Yes San 5 I ` 47.63 in.^4
Board Sheathing None Total Rake Span 16.63 ft TL DefPn Limit 120
Vaulted Ceiling No PV 1 Start 2.08 ft Wood Species SPF
Ceiling Finish 1/2"Gypsum Board PV 1 End 13.58 ft Wood Grade #2
Rafter Sloe 280 PV 2 Start Fb' 875 psi
Rafter Spacing 16"O.C. PV 2 End f F„ 135 psi
Top`Lat Bracing Full PV 3 Start E 1400000 psi
Bot Lat Bracing At Supports PV 3 End Emin 510000 psi
Member Loading mary
Roof Pitch 7/12 Initial Pitch Adjust Non-PV Areas PV Areas
Roof Dead Load DL 10.5 psf x 1.13 11.9 psf 11.9 psf
PV Dead Load PV-DL 3.0'psf x 1.13 3.4 psf
Roof Live Load RLL 20.0 psf x 0.88 17.5 psf
Live/Snow Load LL/SL1,2 50.0,psf x 0.7 1 x 0.7 35.0 psf 35.0 psf
Total Load(Governing LC I TL 1 46.9 psf 1 50.3 psf
Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(CO(IS)p9; Ce=0.9,Ct=1.1,I5=1.0
Member Design Summary(per NDS)
Governing Load Comb CD U+] CL - CF Cr
D+S 1.15 1.00 1 0.40 1.2 - 1.15
Member Analysis'Results Summary
Governing Analysis Max Demand @ Location Capacity DCR Result
Bending + Stress 1414 psi 7.9 ft 1389 psi 1.02 Pass
CALCULATION OF DESIGN WIND LOADS MPI
Mounting Plane`Information
Roofing Material Comp Roof
PV System Type SolarCity SleekMountT11
Spanning Vents No
Standoff Attachment Hardware Comp Mount Type C
Roof Slope 280
Rafter Spacing 16"O.C.
Framing Type Direction Y-Y Rafters
Purlin Spacing X-X Purlins Only NA
Tile Reveal Tile Roofs Only NA
Tile Attachment System Tile Roofs Only NA
,Standing Seam/Trap Spacing SM Seam Only NA
Wind Design Criteria
Wind Design Code ASCE 7-05
WindDesign'Method Partially/Fully Enclosed Method
Basic Wind Speed V 100 mph Fig. 6-1
Exposure Category C Section 6.5.6.3
Roof Style Gable Roof Fig. 6-11B/C/D-14A/B
Mean Roof Height I h 1 25 ft Section 6.2
Wind Pressure Calculation Coefficients
Wind Pressure Exposure KZ 0.95 Table 6-3
Topographic Factor ' KA 1.00 Section 6.5.7
Wind Directionality Factor Kd 0.85 Table 6-4
Importance Factor I 1.0 Table 6-1,
Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V112) (I) Equation 6-15
20.6 psf
Wind Pressure
Ext. Pressure Coefficient U GC -0.95 Fig. 6-11B/C/D-14A/B
Ext.'Pressure`Coefficient Down G Do.n) 0.88 Fig.6-11B/C/D-14A/B
Design Wind Pressure p p = qh (GC) Equation 6-22
Wind Pressure Up p„ -19.6 psf
Wind Pressure Down 18.0 psf
ALLOWABLE STANDOFF SPACINGS
X-Direction Y-Direction
Max Allowable Standoff Spacing Landscape 64" 39"
Max Allowable Cantilever Landscape 22" NA
Standoff Configuration Landscape Staggered
Max Standoff Tributary Area Trib 17 sf
PV Assembly Dead Load W-PV 3.0 psf
PV Dead Load at Standoff P-PV 52 lbs
Net Wind Uplift at Standoff T-actual -312 lbs
Uplift Capacity of Standoff T-allow 500 lbs
Standoff Demand/Capacity DCR 62.4%
X Direction Y-Direction
Max Allowable Standoff Spacing Portrait 32" 65"
Max Allowable Cantilever Portrait 14" NA
Standoff Configuration Portrait Staggered
Max Standoff Tributary Area Trib 14 sf
PV Assembly Dead Load W-PV 3.0 psf
PV Dead Load at Standoff P-PV 43 lbs
Net Wind Uplift at Standoff T-actual -259 lbs
Uplift Capacity of Standoff T-allow 500 lbs
Standoff Demand/Capacity DCR 51.9%
DocuSign Envelope ID:DB7F66E8-3F67-49DB-BD00-A9EF96475E8B
's f, PPA
Crisiorner Name and Address Installation Location Date
Judith Arnost 29 Paddock Ln 10/9/2015
North Andover, MA 01845
29 Paddock Ln
North Andover, MA 01845
Here are the key terms of;roust prepaid. Povv r Purchose Agreement
31
vN,
MOI
DIM i1q
r ' r �
j'F
a Agree rr1 'h2 �S
tenn Yrayh
Initial here Initial herea
f !
'Th
lo `.,.��, rk` gt s.r r ti. DS
Y%F R t jp` h pl 5 t{_ �a`3..-
®We provide a money-back energy performance guarantee. Ja
•We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. .... ... Initial here
•We warrant all of our roofing work. DS
•We restore your roof at the end of the Agreement.• Ja
We warrant, insure, maintain and repair the System. ........... ..............._ ___. ..._......._._ .............. ..._..... ................ Initial hPr
•We fix or pay for any damage we may cause to your property.
•We provide 24/7 web-enabled monitoring at no additional cost.
•The rate you pay us will remain fixed for the term of the Agreement.
®The pricing in this Agreement is valid for 30 days after 10/9/2015.
®You are free to cancel any time prior to construction at no charge.
rPovver Purchase: A,
Your Choices at the End of the Initial Captions for System Purchase:
Amount due at contract signing Term:
®At certain times,as specified in
$0 ®SolarCity will remove the System at no the Agreement,you may
Est, amount due at installation cost to you. purchase the System.
3,320 ®You can upgrade to a new System with ®These options apply during the 20
the latest solar technology under a new year term of our Agreement and
Est. amount due at building inspection contract. not beyond that term.
$3,320
You may purchase the System from
Est.first year production SolarCity for its fair market value as
3,998 kWh specified in the Agreement.
®You may renew this Agreement for up to
ten (10)years in two (2)five(5)year
increments.
4� 5 r,ltl.d4'1I ?x?I Way, i.,AC0288845.. psi :,€ .y a_; t 1186333
Power Purci;ase Agreernent,version 9.0.3,August 24,2n15
SAPC/SFFA Compliant
Contractors License MA HIC 168572/EL-1136MR
�' �'�■
Document generated on 10/9/2015
0-r-Copyright 200E-2015 SolarCity Corporation,Ali Rights Reserved
DocuSign Envelope ID:DB7F66E8-3F67-49DB-BD00-A9EF96475E8B
23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in
YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a
TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement.
DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE
ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Judith Arnost
EXPLANATION OF THIS RIGHT. ^DocuSiiA9,nea by:
24. ADDITIONAL RIGHTS TO CANCEL. Signature: u�'"" 9 W sf
IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL
THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 10/9/2015
THIS PPA AT NO COST AT ANY TIME PRIOR TO
COMMENCEMENT OF CONSTRUCTION ON YOUR HOME.
25. Pricing
The pricing in this PPA is valid for 30 days after 10/9/2015.
Customer's Name:
If you don't sign this PPA and return it to us on or prior to
30 days after 10/9/2015,SolarCity reserves the right to Signature:
reject this PPA unless you agree to our then current pricing.
Date:
Power Purchase Agreement
SolarCity
approved
Signature:
Lyndon Rive, CEO
Date: 10/9/2015
1
The Cotninoniveatlth ofmassachusetts
Deparittrent of IndrrstrialAcerdents
Office of1'tzvestlgadons
v
1' Congress street, suite 100
.Boston,MA 02114-211.17
ivww.tmrss.gov1dia
Workers'Compensation Insurance Affidavit:Buildelrs/Conttracters/Bit~ctrieia ns/Piumberx
Applicant ClIfvrmatiOu Please Print Legibly
Name ($usiness/Organizationtindividual): SolarCity Corp.
,eddre,ss: 3055 Clearview Way
City/State,/Zip; San Mateo CA. 94402 pbone#.888-765-2489
Are you an employer?Check the appropriate box: Type of project(req uitred):
1.EI am a employer with.5,000. `l• n I ani a general contractor and I
ernploysas(full and/or part-tirne).4 have hired the sub-contractors New construction
2.0 1 am a sole proprietor or partner- listed on the attached sheet. 7. n Remodeling
ship and have no employees These sub-c:anbraetors have S. 0 Demolition
working for me in any capacity, employees and have workers'
[No workers` comp. insurance comp.insurance.,
�]Building addition
required.) 5• We are a corporation and its 10.[]Electrical repairs or additions
3.0 I am a homeowner doing all work officers have exercised their I I.Ej.plumbing repairs or additions
tnybelf [NU workers' cramp. s°ighi ufcxaurptiun liar iviirl., 12,E Roof repairs
insurance required.]t c. 152,§1(4),and we have no I3 �/ Other SOlar/PV
employees.[filo workers'
comp. insurance required.1
*Any applicant that ebacks box#t must also fill out the section be)ow showing their tivorktxs'cumlrcasotion gtsltcy iuformatiou.
i Homeowners who submit this affidavit indiealint;They are doing all mrk turd then hire outside contractors crust submit a new affidavit indicating such.
rCoramcwrs that cheek this box must attached an additional shout showing the name orthe wls-contrauors and state whether or not those entilies have
employees. If the sub•contrsctors have employees,they must provide their workers'comp policy number.
1'ain an emplaver that isprovWing workers'compensation.insurance for my enrployees. Below'rs Naep0ry and job site
information,
Insurance Company Name. Zurich American Insurance Company
Policy#or Seit-ins.Lic.#: WC0182015-00 Expiration Hate; 9/1/2016
Job Site Address: tR ?Aaaact. ( City/State/'Zip; /)gXITi LL1ey_p/
Attach a copy of the workers' compensation policy deeluratiou page(showing the policy number and expiration date).
Fzilure to secure coverage as required under Section 25A of MGL c. I52 can lead tp the imposition of criminal penalties of a
fine up to 51,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to:1:250.00a clay against the violator. Be advised thata copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance oaverage verification.
X do hereby eert yy tine paints and penalties ofperjury thot the information provides'above is true and correct
Si 'Hutu — Date; �'l�`f
phone t:
Of,elciul uma only, Do not write Az this area,to be campleted by cloy or town official,
city at,Tolvns Permit[Lieense#
Issuing Authority(circle one):
1.Board of 11valth 2.13nilding Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspeetor
6.Other
Contact Person: phone#;
®r��y®� DATE(MMIDD/YYYY)
A `JLR. CERTIFICATE OF LIABILITY INSURANCEoarl7iz�15
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES,
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER($), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the poticy(ies)must be endorsed. If SUBROGATION IS WAIVED, subject to
the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement(s).
PRODUCER CONTACT
MARSH RISK& INSURANCE SERVICES rt9MN.--....._..___.._. ._... _. _.......... .. .. . ..
PHON$ : FAX
345 CALIFORNIA STREET,SUITE 1300 lAtc.Crs:LEa3)L..._"._...._----. ..... ... ..... . . . ........ .(A1c,No):. ......... ........ ................._
CALIFORNIA LICENSE NO.0437153 F-MAIL
SAN FRANCISCO,CA 94104 _Aoott€ss:. ..... ."............ _. ...... .. ......"........ ........._.. ........ ....".... .._....T---._.................._..
Atin:Shannon Scott 415-743.8334 INSURERS)AFFORDING COVERAGE NAIC#
998301-STND-GAWUE-15.16 INSURER A;Zurich American Insurance Company 16535
INSURED INSURER a:NIA :NIA
SolarCity Corporation - .. .. . . .. .... -._. ....... ... .. .... .._....... +.. .. .... ...
3055 Clearview Way INSURER C:NIAINIA
San Mateo,CA 94402 INSURER.D:American Zurich Insurance Company 40142
INSURER E, ........
INSURER F:
COVERAGES CERTIFICATE NUMBER: SEA-002713836.08 REVISION NUMBER:4
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES-LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
(NSR .._........_._..... .....TADoL7 BIZT._.._._."..---._..._.._..__.... _.......... ..*'Pt3LiCY FF POLICY EXP
LTR TYPE OF INSURANCE POLICY NUMBER I MWDDIYYYY MMIDDlYYYY LIMITS
A comMERCAGNERLABILT09l01205 091012016 3,000,000
CLAIMS-MAD
X J OCCUR I PREM SESo a ouTu enceT_ +_�" . 3_000,000
X SIR:$250,000 MED EXP(Any one person} S 5,000
i .....-- --_.----....--_._----......_ .._..-..... PERSONAL&ADVINJURY_._.�.5.. .......... "........_....__
3,000,000
6,000,000
GEN'LAGGREGATE LIMITAPPLIES PER" I i i GENERAL AGGREGATE
1- .. .. ... ..
-- ° PRO-
F X
POLICY:,," JECT LOC I PRODUCTS-COMP/OP AGG :S 6,000,000
OTHER 8
A AUTOMONLELIABILITY !BAP0182017.00 ;010112015 :0910112016 COMBINED SINGLE LIMIT $ 5,000,000
X ANY AUTO BODILY INJURY(Per person) $
X 'ALL OWNED .X SCHEDULED ;BODILY INJURY(Per accident):F
AUTOS AUTOS i .... ..... ......... ...... ".. ...
X X NON•pVvNED PROPERTY DAMAGE $
. HIRED AUTOS AUTOS
COMPICDLL DED: $ $5,000
UMBRELLA LIAR OCCUR
`E
�......I r ACH OCCURREC
".. .._... .... ...._+.�._... ...........
EXCESS LIAR I CLAIMS-MAOt _ [ AGGREGATE $
E
DED RETENTIONS $
D WORKERS COMPENSATION WC0182014.00(AOS) ;0910112015 :09161/016X s1EaTU oRH
IAND EMPLOYERS'LIABILITY
A YIN; ; ;WC0t82015.00 MA :09101=15 €0910112016 000
ZANY PROPR!£TORIPARTNERIEXECUTIVE - ( } EACH ACCIDENT . ....a$. .. .. . 1000,.....
OFFICER/MEMBER EXCLUDED? �i N/A �._....___..._.._.._.._..... ..
(Mandatory in NH) I WC DEDUCTIBLE:$500,000E L DISEASE-EA EMPLOYEE] S 1 000,000
If yes,describe under _ _.
DESCRIPTION OF OPERATIONS below I E L DISEASE-POLICY LIMIT 1 $ 1,000,000
I
i
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached It more space Is required)
Evidence of insurance.
CERTIFICATE HOLDER CANCELLATION
SolarCity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
3055 CloanAaw Way THE EXPIRATION DATE THEREOF, NOTICE WILL B£ DELIVERED 1N
San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRESENTATIVE
of Marsh Risk&Insurance Services
Charles Marmolejo
0 9988-2014 ACORD CORPORATION. All rights reserved.
ACORD 25(2014!01) The ACORD name and logo are registered marks of ACORD
.. f
� Office of Consumer Affairs and Business Regulation
10 Park Plaza - Suite 5170
Boston, Massachusetts 02116
Home Improvement Contractor Registration
Registration: 168572
Type: Supplement Card
SOLAR CITY CORPORATION Expiration: 3/8/2017
ASTRID BLANCO - - ---- --
3055 CLEARVIEW WAY -- ---- -- — ---
SAN MATEO, CA 94402
Update Address avid return card.Mark reason for change.
Address —I Renewal [� Employment (—I Lost Card
Office of Consumer Affairs&Business Regulation License or registration valid for individui use only
before the expiration date. If found return to:
OME IMPROVEMENT CONTRACTOR
Office of Consumer Affairs and Business Regulation
Registration: 168572 TyP<'' 10 Park Plaza-Suite 5170
Expiration: 3/8/2017 Supplement Card Boston,MA 02116
SOLAR CITY CORPORATION
ASTRID BLANCO
24 ST MARTIN STREET BLD 2UNI _
i510LBOROUGH, MA 01752 _._. ..
Undersecretary Nat valid without signature
'ffice of Consumer Affairs and Business Regulation
10 Park Plaza - Suite 5170
Boston, Massachusetts 02115
Home Improvement Contractor registration
Registration: 168572
Type: Supplement Card
SOLAR CITY CORPORATION Expiration: 3/8/2017
DAN FONZI - ------ - - ----- --
24 ST MARTIN STREET BLD 2UNIT 1 --- ---_-
MARLBOROUGH, MA 01752 -_ - -----__-_- --- _--
Update Address and return card.Mark reason for change.
Address 7Renewal 7 Employment Lost Card
Office of Consumer Affairs&Business Regulation License or registration valid for individul use only
AWOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to:
Office of Consumer Affairs and easiness Regulation
Registration: 168572 Type: 10 park;Plaza-Suite 5170
Expiration: 3(8!2017 Supplement Card Boston,MA 02316
SOLAR CITY CORPORATION
DAN FONZI
op
3055 CLEARVIEW WAY "j-
SAN
>_.-SAN IUTATEO,CA 94402 Undersecretary Not valid without signature
CS-101687
DANIEL 13 FONZI
15 KELLEY RD
WH2WINGTON NA 01897 '
0911312016