Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit # 12/15/2015
Q-0RT#1 q BUILDING PERMIT oo TOWN NORTHANDOVER '' APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received �95 RATlD PY"gay Date Issued: ~� SACHus� IMPORTANT: Applicant must complete all items on this page LOGAT(ON %< "Priint, PROPERTY DINNER H7tUC S, N'DO Print> , MAP NCSs PARCEL: ZONING'DISTRLCT: Historic District yes no Machirte Shop Viillage yes: no TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ❑ One family J Addition ❑ Two or more family ❑ Industrial vAlteration No. of units: ❑ Commercial ❑ Repair, replacement ❑ Assessory Bldg ❑ Others: ❑ Demolition ❑ Other o Se rc >` ❑"Wel( [7 FIoQd lain %D Wet(artds' Watershed District f? P., ❑UVafierfSewer: INSTALL 3q SOL-AP- PANELS ON :X ISTING- P-M F SYsTc, gR-G v F 9,6 a V-w i Identification Please Type or Print Clearly) i OWNER: Name: T-IQUAS SECQNbU Phone: 6107• Wt. -MO) Address: �3 OLYMPIC- LN CQNTRACTOR Marne: bN: P%tC If Phone. 9 a l`C� a CT .. Ac4dre�s:�: 1-t�o4:.-� P��E�tS :7;st %;:�=�:�L� M�=�►J�N 1�C� °13�1;�-E Su eruisor's'Construcfiori License: Ex Date: _0 &pP P 6 / f r Horne:Irn ate rouernentLcense.� " ;�'Ex D : I p G . t ARCHITECT/ENGINEER Phone: Address: Reg. No. FEE SCHEDULE:BULDING PERMIT.$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ EE: $ Check No.: 2 Receipt No.: NOTE: Persons clakr-a-ckink with unregistered contractors do not have ccessto 3Z?guj�7rnty fund II ignature of Agent/Owner Signature of contractor A t%®RTF•F Andover Town of ® to No ® �/ i E ver, ass, ° LAKE �, COCMIC Ht WICK y • 'js A°RATEo J'Py q$ 11smak BOARD OF HEALTH Food/Kitchen MIT T PER Septic System BUILDING INSPECTOR ........................ THIS CERTIFIES THAT ....... Foundation .. .. ol. +�...... Rough has permission to erect .......................... buildings on . ••••• ' Chimney to be occupied as ........k..4.01..... ..... Final provided that the person accepting this permit shall in every B a pect Laws relating to the Inspectionrm to the terms of , Alteration on and on file in this office, and to the provisions of the Codes an y PLUMBING INSPECTOR Construction of Buildings in the Town of North Andover. Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final ELECTRICAL INSPECTOR PERMITI S IN 6 MONTHS Rough ® LESS C T DTIO TA Service Y . ............................................... Final ............... BUILDING INSPECTOR GAS INSPECTOR Pe�'nzit Izectuired t® Occupy BuildiRough Occupancy n Final Display in a Conspicuous lace on the Premises - Do Not Remove FIRE DEPARTMENT pv No Lathing or Dry Wall To Be Done • Burner Until Inspected and Approved by the Building Inspector. Street No. Smoke Det. DocuSign Envelope ID:9C4EF40B-D3F1-4BCA-9479-38AO846F6A4B 01*,#(, 411 Isi, s u nGEVITY' Homeowner's Agent Authorization Form State of Massachusetts Thomas Secondo name) am the owner of the property located at address: 163 Olympic Lane North Andover MA 01845 (print address) I hereby authorize Sungevity or its subcontractor to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a PhotoVoltaic System located on my Property. nocuSAland by, Customer signature: �ZAJ- Mw4orREDA419 Date: 11/16/2015 Print Name: Thomas Secondo SungevitY MA Home improvement Contractors License # 168430 S10,4965SOO 866,SUN,4ALL 66 Frankhr"Stf'00t, St"te 310 S10�4965501 Oakland,CA 94607 USA DocuSign Envelope ID:9C4EF40B-D3F1-46CA-9479-38AOB46F6A4B ,4„444 X140 0, &0106 Homeowner's Agent Authorization Form State of Massachusetts I, Thomas Secondo (print name) am the owner of the property located at address: 163 Olympic Lane North Andover MA 01845 (print address) I hereby authorize Sungevity or its subcontractor to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. DocuSi ad by Customer Signature: ✓ 2 D6C-0Qr77CDA4'19... Date: 11/16/2015 Print Name: Thomas Secondo Sungevity MA Nome Improvement Contractors License # 168430 663 Franklin Street, Swite,310 p,510,496,5500 €366,SUNAALL Oakland, CA 94607 1„1SA 4 S10,49&5501 The Commonwealth of Massachusetts Department of Industrial Accidents w I Congress Street,Suite 100 a Boston,MA 02114-2017 t ` www.mass.gov/dia V Workers'compensation TO BE FILED WITHfTHE P ERMITTING AUTHORITIY tricians/Plum ers. Please Print Le lbl A licant Information Name (Business/Organization/Individual): United Solar Associates, LLC Address:452 Pleasant Street, Second Floor i Malden, MA 02148 Phone#: city/State/Zip. 855-786-1776 Type of project(required): F3a employer?Check the appropriate box: 7. n New construction a employer with 5 employees(full and/or part-time).* g. �Remodeling a sole proprietor or partnership and have no employees working forme in 9 Demolition capacity.[No workers'comp.insurance required.] 10[�Building addition a homeowner doing all work myself.[No workers'comp.insurance required.] I will 11.❑Electrical repairs or additions a homeowner and will be hiring contractors to conduct all workon myproperty.re that all contractors either have workers'compensation insurance or are sole 12plumbingrepairs or additions prietors with no employees. 13.❑Roof repairs a general contractor and I have hired the sub-contractors listed on the attached sheet. SOlar Install se sub-contractors have employees and have workers'comp.insurance: 14.[]✓ Other 6.n We re a corporation and its officers have exercised their right of exemption per MGL c. a 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensationre outside contractors policy information. t Homeowners who submit this affidavit indicating an additional sheet showing the name ooing all work and then 'f the sub-contractors and state must whether or otdthose lentiti s havendicating ch. 'Contractors that check this box must attachedp.policy number. employees. If the sub-contractors have employees,they must provide their workers com p Y I an:an employer that is providing workers'compensation insurance for my employees. Below is thepolicy and job site information. TRAVELERS Insurance Company Name: 7/23/2016 7PJUB-5650763-8-15 Expiration Date: Policy#or Self-ins.Lic.#: N.Andover, MA 01845 163 Olympic Ln City/State/Zip: Job Site Address: (showing the policy number and expiration date). Attach a copy of the workers' compensation policy declaration page( g a fine up to$1,500-00 Failure to secure coverage as required under MGL c• 152,§25A is a crimina form of STO and/or one-year imprisonmestatement P Wtpunishableon ORK ORDERandya fine p e of to$250.00 a nt,as well civil penalties day against the violatthis statement may be forwarded to the Office of Investigations of the DIA for insurance or.A coverage verification. at' s ry that the information provided above is true and correct. Ido hereby certify and thepains nd pe i Date: Si nature: Phone#:855-786-1776 EEenonly. Do not write in this area,to be completed by city or town official. Permit/License# n:hority(circle one):Health2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspec orPhone#• rson: DATE(MMIDD/YYYY) q�O CERTIFICATE OF LIABILITY INSURANCE 12/8/2015 HIS R NEGATIVELY AMEND,EXTEND OR ALTER THE COVERSSUING INSURER(S),AUTHORIZED IZED AGE AFFORDED By THE POLICIES THIS CERTIFICATE IS ISSUED AS A MATTEOR OF INFORMATION ONLY AND CONFERS NO RIGHTS UE ON THE CERTIFICATE HOLDOl CIE ER.T CERTIFICATE DOES NOT AFFIRMATIVELY BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN T CERTIFICATE HOLDER. REPRESENTATIVE OR PRODUCER,AND THE CE IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endors ed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). NAME: A PRODUCER PHONE (A1C,No): 714-625-8290 A/C,No, 714 625 8204 Asset One Insurance ADDRESS: ara@solarinsure.cOm NAIC# 575 Anton Blvd.,3rd FL INSURER(S)AFFORDING COVERAGE 10172 CA 92626 INSURER A: Westchester Surplus Lines Insurance company Costa Mesa INSURER B: TRAVELERS PROPERTY CASUALTY COMPANY OF AMERK 25674 16535 INSURED INSURER C: American Zurich Insurance Coripan United Solar Associates,LLC INSURER D: 452 Pleasant Street,Second Floor INSURER E: MA 02148 INSURER F: Malden REVISION NUMBER: COVERAGES CEIOD RTIFICATE NUMBER: 'll 11:1:11111 REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT DESCRIBED HOEREInN S SIUBJECT TO ALL THETE RMS,TERMS,IS THIS IS TO CERTIFY THAT THE POLICrIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUL D TO THE INSURED NAMEENTD ABOTH VE FOR THE POLICY PER INDICATED. NOTWITHSTANDING AN CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE P AY P LIMITS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN LICYNUMBS HAVE BEEN REDUCED PAID COLA ) IN TYPE OF INSURANCE INSD WVD EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Eaoccurrence) $ 50,000 CLAIMS-MADE OCCUR MED EXP(Any one person) $ 10,000 627527966001 11/10/2015 11/10/2016 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 A GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 PRO- ❑ LOC $ POLICY I JECT $ OTHER: (Ea accident) AUTOMOBILE LIABILITY BODILY INJURY(Per person) $ BODILY INJURY(Per accident) $ ANY AUTO $ ALL OWNED SCHEDULED AUTOS AUTOS (Per accident) NON-OWNED $ HIRED AUTOS AUTOS EACH OCCURRENCE $ 5,000,000 UMBRELLA LIAB X OCCUR AGGREGATE $ 5,000,000 A X EXCESS LIAB CLAIMS-MADE 627527966 001 11/10/2015 11/10/2016 $ DED RETENTION$ X STATUTE ER WORKERS COMPENSATION E.L.EACH ACCIDENT $ 1,000,000 AND EMPLOYERS'LIABILITY YIN ANY PROPRIETOWPARTNER/EXECUTIVE ENIA 7PJUB-5850763-8-15 7/23/2015 7/23/2016 E.L.DISEASE-EA EMPLOYE $ 1,000,000 B (Mandatory in NH)EXCLUDED? E.L.DISEASE-POLICY LIMIT $ 1,000,000 If yes,desci be under DESCRIPTION OF OPERATIONS below ER07771654 5/26/2015 5/26/2016 $522,302.00 C Property DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CANCELLATION CERTIFICATE HOLDER SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THEREOF,THE EXPIRATION DATE I ACCORDANCE WITH THE POLICY PROVISIONS. BE DELIVERED IN Town of North Andover AAUTHORIZED REPRESENTATIVE Attn:Building Department 1600 Osgood St., Building 20,Suite 2035 MA 018457- j North Andover ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 26(2014101) The ACORD name and logo are registered marks of ACORD EL CTR I C I AN I$,SUES THE FING�.ECfRICIAN URNEYMN AS "AE8 J4 ,4 Ism N DANIEL J KGRATH 114 SOYLSTON ST` ttorisrat+ r �.tr1At► tt4s1' MA 02148-731 Do .. Massachusetts �kA1.0EN agent Of PubilcS-atety � 10m aid tarda E�saof EIt F( UA , e i xta'z: r fi License: CSFA4404816 t� DANIEL J MCGRA"i'1K 1 r{ 114 B4YlimorV 3T 7 MALDEN MA 01148 r r if r-„4,,,, .tJ..ef '► 09116!2016 u C�f�s.tottr �, -111"t1,111"rr,nuavi1/1,,1 itur/G fftee of Consumer Affairs&Business Regulation ME IMPROVEMENT CONTRACTOR registration: 168524 Type: ELECTRICAL UNLIMITED JOURNEY PERSON expiration: 3/7/2017 Individual DANIEL?MCGRATH 114 BOYLSTON ST DANIEL MCGRATH MALDEN,MA 02148-7931 DANIEL MCGRATH 114 BOYLSTON ST ---I IEC i4Ji EXti MALDEN,MA 02148 Undersecretary LC.01999.13-E2 10/01/2014 09/30/2015 GNEU STATE OF MAINE DEPT OF PROFESSIONAL""OL PEOLikl ION ,r . F.L€CTr�cu►r�ls"AMININO`BOARD ELEICI'R1CA1. UNLLD417FDI C()NTRAC'LdR ; LICENSE#M$60020703 DANIEL) MCGRATII Ild 13oYLS`I"ON S'T DANIEL MCGRATH NIALDEN,NSA 02149-79-A MASTER ELECTRICIAN --- 1,2016 r G, i l,1 L v _x�” ` ISSUED Aug 26,2013 EXPIRES AugAu0 WO O 4 131/2015 09/30/2"016 EIA,.V-201855-ka ,, PV | ^� STRN(TURAL ENGINEERS December 11, �U15 ' | � Suge,"v � 65 Franklin Street � Oakland, CA34bU/ SubiectStructural(�ed�c�hon�x|ost�|oJonofSolar Panels | Job 'Number: 15O0'O1793 | Client: Thomas Seoondn -22$3998 Address: 183Olympic Lane, North Andover, K8AO1D45 Attn.:ToWhom|tMay Concern Afield nboervabonofUhec0nddionoftheemisbngfrano\ngsystennvVasperfonnedbyenouditbm�mnhnnnSungevih/. From the field observation ofthe property, the existing roof structures was observed asfollows: The existing roof structure consists of: ƒ hin�|�/�ppruxirn�t�|y1Oyeoro|drooDoverRmofP|ywoodiaauPpo�edby2«8 � (�ornpoeitionShingle(1Layer o � | �dadap ' xirnate|y27de8u»emndhsmaa Rafters�D1O"p.o. sd `RF�\Y1A\RR/A/3.Thensftsns�neanp b�ahnq,,mU� ~~ �ect�Uh�hzonto!opanof14ft 2 i between load 8vvm . m«axinnVn»P�g e Composition Shingle(1 Layer ofshingle/approximately 1Oyear old rooMover Roof plywood iesupported bvW | ed�t�pprnxinnate) 27deQnm��ndh�«e� mmxin«u»» Rafters �� 18''oo ��ARRAY2. Therafteroon*so� v ~~ � � of14ft 5 \n bebween|oadbemhnQwalls. projected horiaunt�|�p�� • Applicable Codes=2009 IBC, ASCE 7-05, and NDS-0 ' |eCodas=2OOB |8C` ASCE7-O5. andWDS-D5 • Ground Snow Load= 55Pof V\��RAy3 .� 1O�1 p�fARF�\Y� • Roof Dead Load = 1O.1 psfARR/�/ 1 • "m"ioV0nd �p�ad= 11Un0phExposure Category""~ • Solar nnodV|es=os indicated inattachmddrawings Asmresult ofthe completed field observation and design checks: U) installation ofso\erpen�\e�ndn»od«|�e� T�R/0' 1/ARR/P/3ismdequahatnsuppudNhe\oadingirnposedby e - ARRAY Thenehone, wostructural up@nadweavmnaquined. � posed by the installation of solar panels and modules. Therefony. ARRAY 2 is adequate to support the loading irn no structural upgrades are required. supports ^ d��ndmnodu\�� hadb�en ,evi�vv�denddetenn|nmOpo ee/v/ exceed the requirements solar panel muppo accordance with the 2OO9IBC. |fyou have any questions Vnthe above, donot hesitate tVcall. PAUL K. ZACHER Prepared By-, 100 PZSE. Inc. -StrUcluna| Engineers Roseville, CA 1of1 � 8150 Si�mQ[�in9V �8U\8VQ�� �, �U�hel�� � ����Q@, CA 95661 * 916'961,3960 � '916,961,3965 � � \����]^���� � � .PZSelOom DocuSign Envelope ID: E7F9D52B-E971-49BE-AE59-F26FD35E5F9B sunfun EXHIBIT A SOLAR FACILITY ADDENDUM CONTRACT P87A1VRF94NDRNB THIS SOLAR FACILITY ADDENDUM CONTRACT("Addendum")is made by and between Sunrun Inc.("Sunrun")and Sungevity,Inc.("Contractor")for the design,engineering,procurement,installation,and construction of the Solar Facility described herein.This Addendum hereby incorporates, in total,the terms and conditions set forth in the Master Solar Facility Turnkey Contract("Contract"),and all schedules and exhibits thereto,executed by Sunrun and Sungevity,Inc.in March 10,2014.Capitalized terms contained herein have the meanings set forth in the Contract. SOLAR FACILITY TOTAL SOLAR PREPAID Contract Price:$30,862.04 Host Customer:Thomas C Secondo Street Address:163 Olympic Ln,North Andover,MA,01845 Rebate Level:$0.00 per watt Utility:National Grid TECHNICAL SPECIFICATIONS System Size Description Rating Standard Test Condition Direct Current(STC DC kW) 9.435 CEC Alternating Current(CEC AC kW) 8.478 Generation Equipment Photovoltaic collectors Manufacturer Model number STC DC rating Quantity Array 1 Trina Solar TSM-255PD05.05 255 W 13 Array 2 Trina Solar TSM-255PD05.05 255 W 9 Array 3 Trina Solar TSM-255PDO5.05 255 W 15 Inverters Manufacturer Model number Efficiency Quantity Array 1 SolarEdge Technologies SE5000(240V)w/-ER-US or 0.98 1 A-US Array 2 SolarEdge Technologies SE5000(240V)w/-ER-US or-US 0'98 1 SE3800(240V)w/-ER-US or Array 3 SolarEdge Technologies A-US' 0.98 1 Total Number of Panels: 37 Total Number of inverters: 2 Meter Information Meter Description Manufacturer Meter selected from approved vendor list provided by Sunrun. Model number Meter selected from approved vendor list provided by Sunrun. 11/12/2015 P87A1VRF94NDRNB-A(Prepaid PPA) Page 1 of 2 DocuSign Envelope ID: E7F9D52B-E971-49BE-AE59-F26FD35E5F9B sunrurl EXHIBIT A SOLAR FACILITY ADDENDUM CONTRACT SOLAR FACILITY DESIGN DIAGRAMS Attach the single-line diagram and aerial-view module layout for the Solar Facility to this document. ASSIGNMENT When transfer of the title to the Work occurs pursuant to the Contract,title to the Work shall be transferred to the Person("Assignee")designated in Exhibit A-1. MISCELLANEOUS Neither this Addendum,nor the Contract,creates any employment,agency,partnership,joint venture or other joint relationship between the Parties. Should a conflict arise between the terms of this Addendum and the terms of the Contract that cannot be reconciled,the terms of this Addendum shall govern;provided,however,agreement on a conflicting term in this Addendum shall not operate to modify the conflicting term in the Contract for future addenda executed between the Parties.This Addendum may be executed in counterparts,each of which will be deemed an original,but all of which taken together will constitute but one and the same instrument. SUNRUN INC. SUNGEVITY,INC. DocuSied by: 5i� Signed by: a F' Signat 1CD4F8CBECD74FA... igwhBF83996493... Adam Murray Zak Federer Name Name Operations Associate Authorized AAgept Title Title 11/17/2015 11/12/2015 Date Date 11/12/2015 P87A1VRF94NDRNB-A(Prepaid PPA) Page 2 of 2 2 3 4 5 1 SHEETINDEX PHOTOVOLTAIC SYSTEM SCOPE WORK: PV0.0 COVER AND SITE PLAN INSTALLATION TION OF A SAFE AND CODE-COMPLIANT PV1.0 GENERAL NOTES GRID-TIED SOLAR PV SYSTEM ON AN EXISTING PV2.0 ARRAY LAYOUT RESIDENTIAL ROOF TOP. SYSTEM SIZE: PV3.0 LINE DIAGRAM AC/DC kW STC: 8.64kW\9.69kW PV4.0 LABELS PV5.0 DIRECTORY A EQUIPMENT: KEY: PV MODULES: (38)Trina Solar TSM-255 PD05.05 p,G ,- ---- PROPERTY LINE (1)SOIafEdge SE5000A-U6 5J0 —--CONDUIT RUN Q INVERTER PANEL INVERTER(S): (1)SolarEdge SE380OA-US Q\�y\�� h,\\ DRIVEWAY DRIVEWAY 0 SU DISCO J.--.— FENCE �DC DISCONNECT FIRE CLEARANCE I] AC DISCONNECT STRUCTUAL UPGRADES OQJUNCTIONBOX \ \ O SOLAR MODULE � MONITORING UNIT \ ` 0 MAIN SERVICE PANEL Q COMBINER BOX LOCATION OF(E)MSP, / Q UTILITY METER ❑ROOF INSIDE BASEMENT Q PV METER OBSTRUCTION \ APPLICABLE CODES: 2014 NEC 2009 INTERNATIONAL CODES WITH MA G tTP `�A AMENDMENTS \ ROOF �L \` MOUNTED CONTRACTOR INFORMATION: B CONDUIT, ARRAY 3 UNITED SOLAR ASSOCIATES MALDEN TYP 452 PLEASANT ST. ` [NORTH LDEN,MA 02148 X00,0 O ROOF 3 RISDICTIONAL INFORMATION: O V ANDOVER,TOWN OF 0 '9 00 OSGOOD ST. RTH ANDOVER,MA 01845 �<- O NOTES TO INSTALLER: \ O OF ti �O ITUSHAR.K ATALL SUNEYES REOUIR NOY THAT NO CHANGES HAVE C DE TO THE ARRAY LAYOUT:OMER INFORMATION:AS C SECONDOLYMPIC LANEH ANDOVER,MA 01845694-7463/#2242998SITE PLAN SCALE: N.T.S. NED BY: REV#: DATE: PV-0.0SHAR.K 0 12/4/15 L By: EWCOMB DeIc:—LowYon:Soccntlo-71a30a09Vi sM1col slxa:liK1] TNESEDMWINOs.SPECIFIGTIONS,AND DESIGNS ARE THE PRDPERTY OF SUNGEVITYINC.ND PART SHALLBE COPIED OR VBED FOR OR WITH ANY OTHERWORK OTHERTHANTHE SPECIFIC PROTECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT sUNOENIY INC.BSFMNKHN 5T SUITE sta OAKLAND,CAP<80] AN 3 4 5 1 2 MODULE SPECIFICATIONS (311 Trina Solar TSM-255 PDOSAS SYMBOL KEY: NOTE: MODULE WEIGHT: 41 — RAIL MODULES SHALL NOT BE MODULE LENGTH: s4.95 GREATER THAN 8 INCHES MODULE WIDTH: 39.05 ———— RAFTERS ABOVE ROOF COVERING ROOF 1 SPECS ROOF RAFTER SIZE: 2X8 NOMINAL RAFTER SPAN: 14'-2" FIRE CLEARANCE SOLAR MODUL RAFTER SPACING: 16" --- -® STRING CONFIG. ROOF MATERIAL: COMPOSITE SHINGLE -� STRUCTURAL ARRAY 7 SPECS UPGRADES - NUMBER OF MODULES: 13 �- SOLAR MODULE 10 TOTAL MOD'WEIGHT Obs):IRONRIDGEXR10 RACKING WEIGHT Obs): 10136 A ® MOUNT ! a I L-FOOT -!� ARRAY WEIGHT(lbs): 634.8 ARRAY AREA(sqft): 229 ® SKYLIGHTI j OMSE-LAG SHINGL ARRAY DEAD LOAD(Ibs/sgft): 2.8 ® CHIMNEY ! NUMBER OF MOUNTS: 30 COMPOSITE SHINGLE LOAD PER MOUNT(Ibs): 21.2 PLUMBING OR 5" X 5/16°-LAG ARRAY AZIMUTH(') Z� ATTIC VENT J•, _ _ I 2.5"MIN.EMBEDMENT PER ARRAY TILT(') p ATTIC VENT I SCREW NUMBER OF FLOORS 2 2X8 NOMINAL,16 O.C. ROOF 2 SPECS RAFTER SIZE: 2X8 NOMINAL M®OWING DETAIL RAFTER SPAN: ,16" RAFTER SPACING 16" :I ROOF MATERIAL COMPOSITE SHINGLE ARRAY SPECS NUMBER OF MODULES: 8 TOTAL MOD.WEIGHT(lbs): 328 - - RACKING WEIGH T(Ibs): 61.5 ARRAY 1 CONTINUE j -I I ARRAY WEIGHT(Ibs): 389.5 TO ARRAY 2 140.9 - I ARRAY AREA(sgft): ROOF 1 !I I O I '01 j I ARRAY DEAD LOAD(Ibs/sgft): 2.8 NUMBER OF MOUNTS: 18 I _ LOAD PER MOUNT(Ibs): 21.6 ARRAY2 ARRAY AZIMUTH(') 148 ! I I I ARRAYTILT(') 27 B ROOF 2 5,-$„ I NUMBER OF FLOORS 8'-2" 16'4" o ROOF 3 SPECS BRAY-1 LAYOUT RAFTER SIZE: 2X8 NOMINAL CONTINUE , I � RAFTER SPAN: 1 SCALE: 3/16"=1'-0" FROM ARRAYI I RAFTER SPACING: 16" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 3 SPECS 1 j I o NUMBEROF MODULES: 17 } j TOTAL MOD.WEIGHT(Ibs): 697 - ! I I RACKING WEIGHT ODs): 128.7 ARRAY 3 ROOF 3 CONTINUE TO 'I ARRAY WEIGHT(Ibs}: 825.7 r_ -_ L ARRAY AREA(sqft): ARRAY 3 ARRAY DEAD LOAD(Ibslsgft): 22 84 -1___) 21 I -I � ! I j I I �..._I NUMBER OF MOUNTS: 38 4T& CONTINUE -- — LOAD PER MOUNTObs): 21.7 FROM ARRAY ® ARRAY AZIMUTH(') SB ARRAY TI LT(") - ! I NUMBER OF FLOORS 2 1 .._.. .,.. F- 16'-4" 27 I ARRAY-2 LAYOUT ® - -- 2 SCALE:3/16 =1 0 - - _. n OFA CUSTOMER INFORMATIQN: T 7 I PAUL K. THOMAS C SECONDO _ .I I ZACHER 163 OLYMPIC LANE TRUCTURAL y NORTH ANDOVER,MA 01845 50100 (617)694-7463/#2242998 I 29'5" o /STS` RRAY-3 LAYOUT SSS/�NA` DESIGNED BY: REV#: DATE: PV-2.O 3 SCALE: 3/16"=V-0" TUSHAR.K 0 12/4/15 ENCONSENL �SOxGEVrtY1NC.ee FPPfiNtIN STSUITE S100PHLANG.CABa88T Hy:PNEWCOMB Ovm-1-SocoMP-Y34M90 SVt SFea151m:i101T THESEORAWINGH.SPECIFIGTIONS,ANG OEBIGNS ARf TME PROPERTY OF SUNOEVITYINO.NO PMTSHAlI BE COPIEOOR USED FOR OR WrtN ANY OTHER WOPNOTHERTHAN THE 9PEdFlCPRWECT FOR4YHICH THEY HAVEREEN OEVELOPEO WrtHOUi OUR WWTT 5 4 3 2 SHEET INDEX 1 PVO.0 COVER AND SITE PLAN PHOTOVOLTAIC SYSTEM SCOPE_ OF WORK: PV1.0 GENERAL NOTES INSTALLATION OF A SAFE AND CODE-COMPLIANT PV2 0 ARRAY LAYOUT GRID-TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. PV3.0 LINE DIAGRAM SYSTEM SIZE: PV4.0 LABELS AC/DC kW STC: 8.64kW\9.69kW PV5.0 DIRECTORY A KEY: G - — — PROPERTY LINE EQUIPMENT: Trina Solar TSM-255 PD05.05 P — CONDUIT RUN E]INVERTER PV MODULES: (38) DRIVE DRIVEWAY O SUBPANEL (1)SolarEdgeSE5000A-US \ R �- FENCE 0 OC DISCONNECT INVERTER(S): (1)SolarEdgeSE380OA-US \�� FIRE CLEARANCE AC DISCONNECT cJ\)� STRUCTURAL [SEIJUNCTION BOX UPGRADES SOLAR MODULE O MONITORING UNIT Q MAIN SERVICE PANEL Q COMBINER BOX LOCATION OF(E)MSP, / Q UTILITY METER OBSTRUCTION \ \ \ INSIDE BASEMENT Q PVMETER APPLICABLE CODES: 2014 NEC \ 2009 INTERNATIONAL CODES WITH MA \\\\\\ \\ \\ `'L� AMENDMENTS \ ROOFB ``. MOUNTED CONTRACTORINFORMATION: CONDUIT, ARRAY 3 UNITED SOLAR ASSOCIATES MALDEN TYP 452 PLEASANT ST. MALDEN,MA 02148 ROOF 3 JURISDICTIONAL INFORMATION: o O� O �� NORTH ANDOVER,TOWN OF 1600 OSGOOD ST. O yip NORTH ANDOVER,MA 01845 y NOTES TO INSTALLER: O FOR INSTALLER USE POST INSTALL SUNEYES REQUIRED? NO I CERTIFY THAT NO CHANGES HAVE C BEEN MADE TO THE ARRAY LAYOUT: CUSTOMER INFORMATION: y 2 THOMAS C SECONDO 163 OLYMPIC LANE C P�� NORTH ANDOVER,MA 01845 (617)694-7463/#2242998 SITE PLAN DESIGNED BY: REV#: DATE: SCALE. N.T.S. TUSHAR.K 0 12/4115 sUNOEV,TY1NC Ba FRANKLIN ST SU ITE Sts 0MN D.CA 94 1 By:PNE`NCOMe Dalo..—Lom11rn:5oconEo YN35985V19FooI Slm:ttxll THESE DPAWIN09.SPECIFlCATON9.AND DE910NG ARETHE PROPERTY OF SUNGEVITY INC.NO PART 9HPLL BE COPIED O0.USED FOR OR WITH PCO'OTHER WORN OTMERTHAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CON9EM 1 2 3 4 5 MODULE SPECIFICATIONS SYMBOL KEY: NOTE: (38)Trina Solar TSM-255 ------- RAIL MODULES SHALL NOT BE MODULE WEIGHT: 41 -——— MODULE LENGTH: 64.95 RAFTERS GREATER THAN 8 INCHES MODULE WIDTH: 39.05 ROOF ABOVE ROOF COVERING ROOF 1 SPECS FIRE CLEARANCE RAFTER SIZE: 2X8 NOMINAL RAFTER SPAN: I 16-2" (D STRING CONFIG. SOLAR MODULE RAFTER SPACING: 16" --. r STRUCTURAL ROOF MATERIAL: COMPOSITE SHINGLE UPGRADES �� ARRAY SPECS O "SOLAR MODULE L 1UTOTIA EMOD.MODULEWEIGHTQbs): 533 A MOUNT I IRONRIDGEXR10 RACKING WEIGHT Qbs): 101.8 ® ARRAY WEIGHT L-FOOT SKYLIGHT I j I ❑ ARRAY REA(sgft)s): 6229 QMSE-LAG SHINGLE ARRAY DEAD LOAD(lbs/sgft): 2.8 ® CHIMNEY I NUMBER OF MOUNTS: 30 COMPOSITE SHINGLELOAD PER PLUMBING OR - 1—_ 5" X5/16°-LAG RRAYAZIMOTNT, 238Ibs): ° 21.2 ATTIC VENT ARRAYTILT(*) 27 E3 ATTIC VENT --' - 2.5"MIN,EMBEDMENT PER I1 1 SCREW NUMBER OF FLOORS 2 2X8 NOMINAL,16 O.C. ROOF 2 SPECS I RAFTER SIFE. 2X8 NOMINAL i_... .�.__ MOUNTING DETAIL RAFTER SPACING: 1165• O. - T SCALE: NTS ROOF MATERIAL: I COMPOSITE SHINGLE l ARRAY SPECS I I I i NUMBER OF MODULES: 8 ARRAY CONTINUE - L-4- TOTAL MOD.WEIGHT(Lbs): 326 I RACKING WEIGHT(Ibs): 61.5 TO ARRAY 2 ROOF 1 1 ARRAY REAHsgft): 140.9 ARRAY DEAD LOAD(IbSlSgft): 2.8 NUMBER OF MOUNTS: 18 I I LOAD PER MOUNT(lbs): 21.6 j ARRAY\2 � ' ARRAY AZIMUTH(°) 148 (- ROOF TIARRAY LT(°) 27 B $'-2" 16'-4" 5' " NUMBER OF FLOORS 2 ROOF 3 SPECS RRAY-1 LAYOUT CONTINUE RAFTERNA 2X8 NOMINAL 1 1 2 SCALE: 3/16"=1'-0" FROM ARRAYI RAFTER SPACING: 16" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 3 SPECS w o NUMBER OF MODULES: 17 TOTAL MOD,WEIGHT(lbs): 697 ARRAY 3 ROOF 3 '. RACKING WEIGHT Obs): 128.7 CONTINUE TO _ ARRAY WEIGHT Qbs): 825.7 ARRAY 3 I I ARRAY AREA(Sgft): 299.4 ......... ,..._..i 2 (.:\ AZ _ ARRAY DEAD LOAD(lbs 2.8 CONTINUE ��- {1,::/L--. I t _ ._.� LNUMBER OF OAD PER MOO TQb)Isgft 238 17 : ) ZFRO I I ARRAY AZIMUTH(') 58 ARRAYTILT(°) 27 1 1 L . .. 6'-4" 6,_8,. NUMBER OF FLOORS 2 IjRRAY-2 LAY2SCALE:3/16"=V-0" C CUSTOMER INFORMATION: - _i - THOMAS C SECONDO PAUL K. 1) ZACHER m 163 OLYMPIC LANE 1 1 1 �1TRUCTURAL NORTH ANDOVER,MA 01845 50100 (617)694-7463/#2242998 6-3 29-5" o IS RRAY-3 LAYOUT SSS/ONAL ' DESIGNED BY: REV#: DATE: 3 SCALE: 3/16"=V-0" PV-2.0 TUSHAR.K 0 1 1214/15 NGENTYINC.ed FRANI°1N ST SUITE3100ANtFN6.CA@A6BT BY.ANEWCOMB Ooie:—LowIbP:SewMo-]34Tdae5V15H"el Sim:It><t: THESENGS.SPECIFIGTIONS.AND DESIGNSARE THE PROPERtYOFSUNGEVRTINL.NO PARTSHN.L DE COPIED OR USFD FOR O0.WRH ANY OTHER WORKOTHERTHAN THESPELIFIL PROJECT FOR NTIICH THEY HAVE BEEN OENELOPEDwITHOIITOURWRRTEN CONSENT 1 2 1 3 1 4 5 ELECTRICAL KEYINVERTER 1 SPECIFICATIONS INVERTER 2 SPECIFICATIONS MODULE ELECTRICAL SPECIFICATIONS SOLAREDGE SE5000A-US SOLAREDGE SE380OA-US (38)Trina Solar TSM-255 PD05.05 f1 BREAKER RATED WATTS(EACH): 5000 RATED WATTS(EACH): 3800 SHORT CIRCUIT CURRENT(Isc): 8.88 �— SWITCH AC OPERATING VOLTAGE(V): 0 0 AC OPERATING VOLTAGE(V): 240 OPEN CIRCUIT VOLTAGE(Voc): 38.1 0 SCREW TERMINAL AC OPERATING CURRENT(A): 21 AC OPERATING CURRENT(A): 16 OPERATING CURRENT(IMP): 8.37 m FUSE NUMBER OF MPPT CHANNELS 0 NUMBER OF MPPT CHANNELS 0 OPERATING VOLTAGE(VMP): 30.5 • SPLICE INVERTER EFFICIENCY: 1 0.98 INVERTER EFFICIENCY: 0.98 MAX SERIES FUSE RATING: 15 13F EARTH GROUND INTEGRATED DC DISCONNECT INTEGRATED DC DISCONNECT STC RATING: 255 M CHASSIS GROUND INVERTER I INPUTSPECIFlCATIONS INVERTER 2 INPUT SPECIFICATIONS PTC RATING: 232 -—— GEC NOMINAL CURRENT PER STRING(Inom): 8.8 NOMINAL CURRENT PER STRING(Inom): 11.7 1 DESIGN CONDITIONS EGC NOMINAL VOLTAGE(Vnom): 350 NOMINAL VOLTAGE(Vnom): 352HIGHEST 2%DB DESIGN TEMP("C); 32 MAX SYSTEM VOLTAGE(Vmax): 500 MAX SYSTEM VOLTAGE(Vmax): 500 MIN.MEAN EXTREME ANNUAL DB("C): -18 MAX CURRENT PER STRING(]max): 15 MAX CURRENT PER STRING(Imax): is A MAX INPUT CIRCUIT CURRENT(Imax): 3o MAX INPUT CIRCUIT CURRENT(]max): 15 (3)#B THWN-2 (3)#8 THWN-2 (3)#8 THWN-2 (3)#B THWN-2 (6)#10 PV-Wire (6)#10 THWN-2 (3)#10 THWN-2 (1)#B GEC (1)#B GEC (1)#B GEC (1)#8 GEC (1)#10 EGC (1)#10 EGC (1)#S GEC 3/4"EMT 3/4"EMT 3/4"EMT 3/4"EMT FREE AIR 3/4"EMT 3/4"EMT (N)MIN.60A AC Combiner METER SUB PANEL (N) AC DISCONNECT, SUPPLY SIDECONNECTIONWITH N POLARIS BLOCK OR SIMILAR INVERTER W/INTEGRATED 60AMP, AC DISCONNECT, DC DISCONNECTS NON-FUSIBLE,C-H 60AMP,222NRFUSIBLE APPROVED ED CONNECTOR AND ————_—— DG222URB C-H DG222NRB APPROVED CONNECTOR 1 STRING OF + ! -AC 30A 2P METER 50A FUSE PV 200A MAIN BREAKER 11 MODULES OPT.CURRENT=8.01A DC—. OUTPUT LOAD LINE LOAD LINE —— 1 STRING OF + I(E)LOADS 11 MODULES \ I (E)200A GO MSP INVERTER OPT.CURRENT=8.01A (E)LOADS 240V 2P 3.W 1y ------- (3)#10 THWN-2 L____ _ -- (1)#e GEC 3/4"EMT B wl i (N)SE380OA-US INVERTER W/INTEGRATED DC DISCONNECTS GEC IRREVERSIBLY SPLICED TO 1 STRING OF + -AC 20A 2P EXISTING DEC OR BONGED DIRECTLY 16 MODULE TO ExISTING GROUNDING ELECTRODE OPT.CURRENT=11.66A DC OUTPUT (IF A7ROOF MIN.NEMA3R UL LISTEINVERTER BOX WITH 90'C TERMIN LOCAT C Inom=(16 x 255W)/350V=11.7A CONDUIT ELEVATION:1/2 TO 3-1/2"=22'C 38 MODULES TOTAL OPERATING VOLTAGE=350VDC(REGULATED) HIGH AMBIENT TEMPERATURE:32°C 38 x 232(PTC WATTS)x 0.98=8640 CEC WATTS CUSTOMER INFORMATION: EXTREME LOW:-18°C ROOFTOP AMBIENT TEMP(Tcorr):54°C=0.76 SE5000A-US MAX OUTPUT CURRENT=21A THOMAS C O CONDUIT FILL(Cfill):0.8 BREAKER SIZE=21A x 1.25=26.25A=>30A 163 OLYMPICC LANE SE380OA-US MAX OUTPUT CURRENT=16A NORTH ANDOVER,MA 01845 CONTINUOUS USE=Imax'1.25=15A BREAKER SIZE=16A x 1.25=20A=>20A (617)694-7463/#2242998 CONDITIONS OF USE=Imax/Tcorr/Cfill =15A/0.76/0.8=24.67A CONDUCTOR SIZE FOR 24.67A DESIGNED BY: REV#: DATE: INSTALLATION SHALL USE MIN.#10 AWG PV-3.0 TUSHAR.K 0 12/4/15 1NOEVITYINC.00FRANIGINSTSUITE3100AKLAND.CAW" By ANEWCOMB Dnt°:_Lrcatlon:GocOM°-12a7BBe SV19K°ol Sim:—17 THESE DRAWINGS.SPECIFICATIONS.AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC.NO PARTSHALL BE COPIEDOR USED FOR OR WITH ANY OTHER WORN OTHERTHAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEM STRUCTURAL ENGINEERS December 4, 2015 Sungevity 66 Franklin Street Oakland, CA 94607 Subject: Structural Certification for Installation of Solar Panels Job Number: 1500-01793 Client: Thomas Secondo-2242998 Address: 163 Olympic Lane, North Andover, MA 01845 Attn.: To Whom It May Concern A field observation of the condition of the existing framing system was performed by an audit team from Sungevity. From the field observation of the property, the existing roof structures was observed as follows: The existing roof structure consists of: • Composition Shingle over Roof Plywood is supported by 2x8 Rafters @ 16"o.c. at ARRAY 1/ARRAY 3. The rafters are sloped at approximately 27 degree and have a maximum projected horizontal span of 14 ft 2 in between load bearing walls. • Composition Shingle over Roof Plywood is supported by 2x8 Rafters @ 16"o.c. at ARRAY 2. The rafters are sloped at approximately 27 degree and have a maximum projected horizontal span of 14 ft 5 in between load bearing walls. Design Criteria: • Applicable Codes=2009 IBC,ASCE 7-05, and NDS-05 • Ground Snow Load = 55 psf • Roof Dead Load = 10.1 psf ARRAY 1/ARRAY 3 ; 10.1 psf ARRAY 2 • Basic Wind Speed= 110 mph Exposure Category C • Solar modules=as indicated in attached drawings As a result of the completed field observation and design checks: • ARRAY 1/ARRAY 3 is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. • ARRAY 2 is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the 2009 IBC. �oFs If you have any questions on the above, do not hesitate to call. PAUL K. s9°ti G ZACHER Prepared By: TRUCTURAL rte„ PZSE, Inc. -Structural Engineers 50100 Roseville, CA �oc �/STE� SS/ONM- 1 of 1 8150 Sierra College Boulevard,Suite 150 • Roseville,CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com TSM-DC A° Hone,/'O IN BLACK M-250 TSM-255 TSM-260 TSM-265 TS DIMENSIONS OF PV MODULE TSM-DC05A.05 ELECTRICAL DATA @ STC DC05A.05 DC05A.05 DC05A.05 DC05A.05 250 255 260 265 941 mm Peak Power Watts-Plan%(WP) 0/+3 0/+3 0/+3 0/+3' - - Power Output Tolerance-Pnvx(%) 8 29. 30.1 30.2 30.6 1NxT0+ o Maximum power voltage-VolP(V) 861 8.66` sot 8.38 8:48 ,PierE Maximum Power Current-lwp(A) 38.1 38.2 38.4 38.5 4e 9.12 8.91 o Open Circuit Voltage-Voc(V) 8.98 9.15 9.20 }uT^ 1'4"o`E Short Circuit Current-Isc(A) 15.9 16,2 0 3 Module Efficiency rim 01) 15.3 15.6 STC:Irradian-e a Average efficiency red/uctioneolTemperature 25*C,f 4.5%at 200 W/m cicording toEN609041. to EN 60904-3. E o E 3 3 TSM-250 TSM-255 TSM-260 TSM-265 ELECTRICAL DATA @ NOCT DC05A.05 DC05A.05 DC05A,05 DC05A.05 183 186 190 194 Maximum Power-Pnux(WP) 26.9 269 270 27.2 Maximum Power voltage-Umy,(V) 6.93 7.04 7.13 6.89 6�43GPWO WHOLE A ♦ A Maximum Power Current-1-1(A) 34.8 : 35.0 33.8 ;34.6 u WIN MJ.e Open Circuit Voitage-Uoc(V) -7.14 7.20 7.34 7.40 Short Circuit Current-Isc(A) 812mm 180 NOCT:Irradiance at Boo W/m'.Ambient Temperature 20°C,Wind Speed 1 m/s. Back View MECHANICAL.DATA Monocrystalline 156 x 156 mm Solar Cells CellOrientatfon 60 cells(6x 10) E1650 x 992 x 35 mm E Module Dimensions Weight 18.6 k9 Glass High Transparency Solar Glass 3.2 mm (( 35mm A-A Black Backsheet Frame Black Anodized Aluminium Alloy IF,65 rated I-V CURVES OF PV MODULE TSM-255 DC05A.05 J-BOX Photovoltaic Technology Cable 4.0 mm',1000 mm Cables Connector Original MC4 10.m 9.°t t000W m' 8" m MAXIMUM RATINGS 7.- TEMPERATURE RATINGS +2°K Operational Temperature -40 to+85°C a 6N 44°C(_ ) c m Nominal Operating Cell 1000V DC(IEC) u4°, Temperature(NOCT) Maximum System aro 200W/m' TemperafureCoefficient ofPux -0.41$/°K Voltage \ Temperature Coefficient of Voc -b.32h/°K Max Series Fuse Rating i5A 0'0m t0.° Temperature Coefficient oflsc 0.053%/°K Volloge(V) WARRANTY 10 year Product Workmanship Warranty CERTIFICATION 25 year Linear Power Warranty 1EC61215/EN61215 (Please refer to product worronly for details) IEC61730/EN61730 o IEC 627162 PIG 1917/05.11 N+ IEC 61701 DIN EN 60066-2-68 LC2 i MCS BBA 0016 PACKAGING CONFIGURATION Z Modules per box:29 pieces -- Modules per 40'container:812 pieces CIE PV CYCLE -SG4 ONS RE THE PRODUCT. solar OTrina solar Limited.All rights reserrvved.specifications sinclludedlin his da asshhe t are su (D 2013bject to change without notice. Smart Energy Together Ingle Phase linve t us fo North rnerica am% soft SE3000A-US/SE380OA-US/SE5001 S 0 -ze=@W- SE760OA-US/SE10000A-US/SE1140OA-US SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE7600A US SE10000A 8V SE11400A US 9980 @ 20 11400 VA OUTPUT 5000 6000 7600 10000 @240V 3000 3800 ................ . ....... .2088. .......2000..... VA . ................ 10800 @ 2088 12000 Nominal AC Power Output ..•••••••• • • """' � 8350 ••"" "' ' 5400 @ 2088 6000 ................ ........ •10950,�240V.. .................. ........... 4150 ............... 3300 5450 @,?408,• ................ ✓ Max.AC Power Output ,•..•„•........ ............... ... ✓ ..........its. — AC Output Voltage Min-Nom-Max. _ ✓...... ........✓... 183-208-229 Vac ”'•........... ........................................... ✓ ✓ AC Output Voltage Min:Nom:Max ttl ...... .................. .................. .......... 211 240 264 Vac .................. .................. ...HA..... 59.3 60 60 5 with HI country s..... .57. 6..60.48 @ 2088 AC Frequency Min,:Nom..M.......... ................ .......16...... ...24 @ 2088�. ...... 25......1......32.......1...42 240.....1......475....... ........... Max.Continuous Output Current 1?.5......1...............1..21.x° 2408...1.......... ....A..... 1.. .............................................. Yes ............. ........ ......... Yes GFDI Threshold ••••• • • ••• y Configurable Thresholds .. Protection,Countr utilityMomtonng,lslanding 13500,.,,,• , 15350 ., W .... 6750 8100 10250 INPUT 5100 "" "' 4050 .. Maximum DC Powe.i:0 ).....I., .... ...... vd� Yes.................... .... Transformer,less,Ungrounded......... ........................................................... V ... 566 325 @ 2088[,350 @ 2408......... .................. .................. ...Adc ............................. .... ..... . Max,Input Voltage..................... ............................................................ 30 .@..024,08..1......345....... ........... 18 3 9.5......1..... 13 1 15;5. 2408..1................1................1... Nom.DC In ut Volta e .............. P.. ......�.................. . Max.Input Current"' c 45 ax.In ut Short Circuit Current...... :. ......Yes......................................................... :..:..... .........P... ..................... • , 600kg 5ensltivlt................ Reverse-Polarity Protection 98 ................. ............................................. 98.3 98........ .......98........ ........... Ground Fault Isolation Detection 98 2 98 3 97 @ 2088 97.5 ............. ................ I... 97.7 6.... . I......98...... ..97.5 @ 2088 97.5 Maximum Inverter Efficiency 97.5 97.5�•2408„ ... ......... ... .... .............. 97.5 2408 <4 98.x......... . ' ............ .. . CEC Weighted Efficiency............... ................ ............... . <2.5 ...............I..... Nighttime Power Consumption ADDITIONAL FEATURES Bee o ttonal) R5485,R5232 Ethernet Zlg. „l,P„ ......... .•...... •.,, •••,..•,.•• Op tionall3l..... .. Supported Communicationlnteraces .•,,,,,. .. Revenue Grade Data,ANSI C12;1 •••••••' •• id shutdown kit is installedl4l ... •••• Functionality enabled when SolarEdge rap' Rapid Shutdown—NEC 2014 690.12 STANDARD COMPLIANCE UL1741,UL1699B.UL1998•.CSA 22.2 ......, Safet IEEE 1547 •.•••••• ......... .. ......... .......Y................................. FCC partly class B Grid Connection Stand.... ........... .........•••••••• """ Emissions " 3/4"minimum/8;3 AWG ........... INSTALLATION SPECIFICATIONS ... . 3/4 minlmum/16 6 AWG 3/4°minimum/1-2 strings/ . .......... . . ................................ . 16-6 AWG AC output conduit size/. range 14-6 AW............... .•••••••••• ... i / ••••••"""""'••.•...•.. 30.Sx12.5x10.5/ n ....................... ............... DC input conduit size/#of strings/ 3/4':minimum/1:2 strings AWG range...:......................... . Dimensions With Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 775 x 315 x 260• .•.... .•i...kg ...... . ......... .......... .......................... ........... 88.4/,40.1............. ..... 54.7/24.7 (HXWXD)................................ 51.2/23.2 Natural Weight with Safety Switch............. ................................ ............................ convection and internal Fan,(user replaceable) Natural Convection fan(user Cooling re,laceable ...... ............................ ...dBA... ...........I................... <50 ......... ...I.......25 ....................:sl Noise .....I.............. ..............................-13 t...140/ + 40 to+60 version available ) in.-Max.operatingTemperature 13 to+140/ 25 to 60 Ran a NEMA 3R........................................................ ........... ....................... g.................................... ........................... Protection Rating. ..................... ..................................... ili For other regional settings please contact SolarEdge support. . t current to mpu P)Revenue higher current soure ma grade inverter P/N:SExxxxA'us000NNR2(for 760OWbe use&the inverter will limit its inverter:SE7600AhU5002NNR2)ed. NI Rapid shutdown kit P/N:SE1000-RSD-S1. (5)-40version P/N:SExxxxA.US000NNU4(for 7600W inverter.SE7600A-U5002NNU4). iso 1 sunsPEc e e• o _ -IN XANNIN =72__=�I Roof Mount System ,62'M IRONRIDGE XR10RaiI XR100 Rail XRI000 Rail Internal Splices TW All rails use internal splices A low-profile mounting rail The ultimate residential A heavyweight mounting for regions with light snow, solar mounting rail. rail for commercial projects, for seamless connections. 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws Moderate load capability Heavy load capability Extreme load capability Varying versions for rails Clear&black anod.finish Clear&black anod.finish Clear anodized finish Grounding Straps offered Tilt Logs Standoffs -Feet Slotted L FlashFoot Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle,up to 45 degrees. Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail IBC&IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable surjar's toughest rooffs. Clamps&GroL,.rd�ng IronRidge builds the strongest roof mounting system in solar.Every component has been tested to the limit End Clamps Grounding Mid Clamps -6, T-Bolt Grounding Lugs Accessories and proven in extreme environments. Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and is also why our products are fully certified,code compliant and backed by a 20-year warranty TN no N Strength Tested PE Certified Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and All components evaluated for superior Pre-stamped engineering letters modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. DIM structural performance. Is available in most states. Mill finish&black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips Sizes from 1.2Z'to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps Class A Fire Rating Design Software Optional Under Clamps Mill&black stainless Swivels in any direction UV-protected polymer resistance Online too]generates a complete bill of Free PesaLtrces Certified to maintain the fire ri rating of the existing roof. materials in minutes. --ign Assistai A�<' NABCEP Certified Training FW Earn free continuing education credits, Go from rough layout to fully Integrated Grounding 20 Year Warranty engineered system.For free. .1 91- while learning more about our systems. Go to konRidge.,,Omltraining UL 2703 system eliminates,separate Twice the protection offered by Got lronridqe.com*�m m odule grounding components. competitors. TSM-DC05A.o5 Honed IN BLACK TSM-250 TSM-255 TSM-260 TSM-265 DIMENSIONS OF PV MODULE TSM-DC05A.05 ELECTRICAL DATA @ STC DC05A.05 DC05A.05 DCOSA.05 DC 565.05 250 255 260 941 mm Peak Power Watts-P/AAx(WP) 0/+3 0/+3 0/+3 0/+3 power Output Tolerance-PAux(%) 301 30.2 30.6 I o 29.8 8.66 Jovaou Maximum Power voltage-VAwr(V) 8,48 8.61 o sox 8.38 J Maximum Power Current-Ir.+rP(A) 38.2 38.4 38.5 wnw3ure ` Open Circuit Volta38.1 ge-Voc(V) 9.15 16.2 9.20 i 4o0 W Z usTA�u�;G eo.e Short Circuit Current-Isc(A) 8.91 8.98 15.3 15.6 15.9 3 Module Efficiency rl-h) 3 Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. STC:Irradiance 1000 W/m2,Cell 2 according to EN 60904-1. sD Average efficiency reduction of 4.59-1200 W/m 3 TSM-250 TSM-255 TSM-260 TSM-265f ELECTRICAL DATA @ NOCT DC05A.05 DC05A.05 DC05A.05 DC0��.0� 183 186 190 Maximum Power-PAux(WP) 26:9 26.9 27.0 27.2 Maximum power Voltage-UwP(VI 7.04 7.13 6,89 6.93 6043o;ouw»G�U A A Maximum Power Current-INaP(A) 34.8! 35.0 33.8 34.6 rz o,nw riore Open Circuit Voltage-Uoc(V) ' 7.34 7.40 ..7.14 7.20 Short Circuit Current-Isc(A) 1 812mm 180 NOCT:Irradiance at 800 W/m2,Ambient Temperature 20°C,Wind Speed 1 m/s. Back view MECHANICAL DATA Solar Cells Monocrystalline 156 x 156 mm 60 cells(6 x 10) Cell Orientation 1650x992 x35 mm EModule Dimensions weight 18.6 kg Glass High Transparency Solar Glass 3.2 mm 35 A-A Backsheet Black Black Anodized Aluminium Alloy Frame J-Box IP 65 rated 7•V CURVES OF PV MODULE TSM-255 DC05A.05 Cables Photovoltaic Technology Cable 4.0 mm2,1000 mm Connector r Original MC4 10, 9.ro 8mm MAXIMUM RATINGS 7.- TEMPERATURE RATINGS Operational Temperature -40 to+85-C 6.- 44°C(±2°K) 1000V DC(IEC) Nominal Operating Cell U 4� Temperature(NOCT) Maximum System 0.41%1°K Voltage 3° 20OW/m Temperature Coefficient of P- -0.41%11K Series Fuse Rating 15A J_ Temperature Coefficient of Voc -0.32%!°K o- 101 top Temperature Coefficient ofisc 0.053%1°K Vollage(V) WARRANTY l0 year Product Workmanship Warranty 25 year Linear power W orranty CERTIFICATION IEC61215/EN61215 )Please refer to product warranty for details) co IEC61730/EN61730 rr z IEC 627162 PIG 1917/05.11 IEC 61701 DIN EN 60068-2-68 LC2 MCS BB A0016 _®I PACKAGING CONFIGURATION z -, wr Modules per box:29 pieces N MLS,. � `il L• per 40'container:812 Pieces j ~ Modules p ® .. PV CYCLE 0Limited. uswithout notice. CAUTONSAFETYADINSTALATIONINSTRUCTIONS NlBE[ [ llded n this are subject to change 201n-SoalSPec catS Toin-asolar Smart Energy Together Ingle Phase Inverters for orth America solar m SE3000A-US/SE380OA-US/SE5000A 1 SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US SE380OA-US SE5000A-US 1 SE6000A US SE760OA-US SE10000A-US SE11400A-US VA 9980 @ 208V 11400 6000 7600 •"' OUTPUT 3800 5000 10000 @240V 3000 ................ . ... ... ........ .............. . ......6 0.0 0. 10800 @ 208V 12000 VA "' ""' 5400 @ 208V 8350 240V Nominal AC Power Output 6000 10950,@....... ..........•••••••• •••"""" ...................... . ........ 4150 . .. . ............ . .. 3300 5450 a�240V 6666... 6666•........... Max.AC Power Output ...... AC Output Voltage Min:Nom.Max!' ✓ ✓ 183;208-229 Vac..................... ✓ ✓ AC Output Voltage Min:Nom:Max!t) ✓ ✓ 593 60:,60:5.with Hl country settin�,57..60 60:5)............. .................. ....HA..... 211-240-264 Vac.,.,..•,, 48 @ 208V 666.......6 47.5 AC Frequency Min.:Nom:Max!'1....... ................L.....18... ..I. ...� 240V ...."' 24 @ 208V 25 32 42 °�.......... ................ A 12.5 21, ,240V... ................ ........ Max.Continuous Output Current Yes .... .... ..... .... .... ....................... ........ ......... ......... Yes GFDI Threshold...,, ••• ""' Utility Monitoring,Islanding Protection,Country Configurable Thresholds 10250 13500,.,••, 15350.,•„ , ,W..... 6666 6750 8100 INPUT 4050 5100 ..... I.......... Maximum DC Power(STC) •... . ......... .... ..... ....... ... ........Yes.... .....................................6666 6666. Vdc ..... soo ....................................................... .. vac ... Transformer,Iess,Ungrounded ... ............... Adc 325 @ 208V/350 @ 240V 33 @ 208V 34.5 ' ............ 6666.. ... x.Input Voltage..................... ........................................................ .... 6666. ......... ................. .. 18 30.5, ,240V..I..........66...... .........66 Nom.DC Input Voltage................. ......9.5...... . 13 115,5 240V..I................I......23.......I... @ Max.Input Current(2) I .............. Adc.... 45 .......................................... ......... Yes ... .............. Max.InputShort Circuit Current,•,,,, •' 600ko Sensitivity ....98 6666. ......98 6666. .'/0••.. 6666... 6666 Reverse-Polarity Protection ,,...... .. .................. ........................ ............................................... 98.3 98 ........ ....... Ground Fault Isolation Detection 98 2 98.3 97 @ 208V 9765 % ................ .... ........3 .... 97.7 .......... I......98...... ..97.5 @ 208V 97.5 Maximum Inverter Efficiency 97,5 97.5.e.240V„ „ .............. 97.5 98 R•240V,,, , • ........... . Weighted Efficiency "<2 5 CEC Weig .............. . Nighttime Power Consumption 6666 6666 ADDITIONAL FEATURES R5485,RS232 Ethernet ZigBee(optional) ...................6666.. 6666 ........ ........ ............... pptionalia)..... ......... . Supported Communication Inter aces ...6666.. 6.666... (4) 6666. 6666... .•••••• id shutdown kit is installe Revenue Grade Data,ANSI C12 1 Functionality enabled when SolarEdge rap . 6666.. ......... Rapid Shutdown—NEC 2014 690.12 ,,,,,...... STANDARD COMPLIANCE U L1741,UL1699B,•UL1998,CSA 22:2,.••................... . . 6666 IEEE1547 .. „ .... 6666 ......... Safety................................ 6666... FCC partly class 8 Grid Connection Standards ; 6666 ................. 6666. Emissions 3/4 minimum/8-3 AWG , ,,,,,,..... INSTALLATION`SPECIFtCAT10Ns ••••• "' g/4' minimum/1-2 strings/ 3/4'minimum/16-6 AWG ,•,,,,,, , ... 1-2 strings/16 6 AWG 14 6 AWG............. ........... AC output conduit size/AWG range•• 3/4"minimum/ •••""""""•• m/ """"• 30.5x12.5x10.5/ DC input conduit size/#of strings/ 775 x 315 x 260 AWG,range ..................tch 30.5 x 12.5 x 7.2/775 x 315 x 18 54.7/24.7... ................. ............. 6666. . . (HXWXD)................................ ...........51.2/23.2 .........I................................ Natural... .............. Weight with Safety Switc convection and internal Fans(user replaceable) Natural Convection fan(user Cooling re placeable ...........••• dBA P.........). . ...............................25.........;'.................... .................................................... F .... ............................. 666.....6 Noise •••• """""'•••���• + 40 to+60 versionavailableis) .................miler tune -13 to+140/ .. t.. 60 Min.Max.OperatingTemperature .......................................................NEMA 3R........................................................ ........... .Range................................... . .................... Protection Rating ................... .......................................... ........................ iii For other regional settings please contact SolarEdge suppo la)Revenue grade inverter P/N:SExxxxA-US000NNR2(for 760OW inverter:SE7600AhU5002NNR2)e (4)Rapid shutdown kit P/N:SE1000-RSD-Sl. A-U5000NNU4(for 7600w inverter.SE7600A-US002NNU4). (s)-40 version P/N:SExxxx sunsPEc e IRON RIDGE Roof Mount System - "`5G"S — ------- - XR10 Rail XR100 Rail XR1000 Rail Internal Splices fl A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 6's annin capability 8'spanning capability 12'spanning capability Self-tapping screws r ` , Moderate load capability Heavy load capability Extreme load capability Varying versions for rails Clear&black anod.finish Clear&black anod.finish Clear anodized finish Grounding Straps offered c FlashFoot Slotted L-Feet Standoffs Tilt Legs ANEM Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights, angle,up to 45 degrees. Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail IBC&IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable E`L for soiar'S toughest rool's- ,r. IronRidge builds the strongest roof mounting system in solar.Every component has been tested to the limit and proven in extreme environments. End Clamps Grounding Mid Clamps O T-Bolt Grounding Lugs O Accessories Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and is also why our products are fully certified,code compliant and backed by a 20-year warranty. NOn_, Strength Tested PE Certified c All components evaluated for superior Pre-stamped engineering letters Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and structural performance. available in most states. modules at ends of rails. in the middle of the rail, rail's top slot. organized look for rails. Mill finish&black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps Class A Fire Rating Design Software Optional Under Clamps Mill&black stainless Swivels in any direction UV-protected polymer Certified to maintain the fire resistance Online tool generates a complete bill of rating of the existing roof. materials in minutes. — `rec Resources Design Assistant A< NABCEP Certified Training Integrated Grounding 20 Year Warranty = Go from rough layout to fully . ' v, Earn free continuing education credits, engineered system.For free. A while learning more about our systems. UL 2703 system eliminates separate Twice the protection offered by Go 3o IranP;dge,cam/rm _– Go to lronRidge.com/training module grounding components. competitors. _+ L