Re: Subsurface Sewage Disposal System Plan for 602 Boxford Street,Lot 2 (Map 105C,Lot22)
Dear Mr. Christiansen,
The proposed wastewater system design plan for the above site dated June 9, 2015 and received on June
10, 2015 has been reviewed. Unfortunately,the plan cannot be approved until the following items are
corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met
by this design follows each item.
1. The proposed grading provides more than 3' of cover over the septic tank and one portion of the
soil absorption system(3 10 CMR 15.221(7)).
2. Cleanouts are required at all bends in the building sewer line(3 10 CMR 15.222(8)).
3. Clarification is needed for the design intent and soil removal. It appears the design is proposing
removal of the A soil layer and retention of the B soil layer. The B soil layer is a Class II soil but
the design calculations are based on a Class I soil(3 10 CMR 15.220).
4. Please label the proposed finished grade over each disposal trench to provide clarity for the
installer.
Please feel free to contact the office or Mill River Consulting at 978-282-0014 with any questions you
may have. We look forward to working with you to obtain a wastewater treatment and dispersal system
which will be in compliance with all regulations and assure protection of public health and the
environment of North Andover.
i cerely,' �
f
Michele Grant
Health Inspector
cc: S &L Homes
File
Page 1 of 1
North. Andover l lealth Department, 1600 Osgood. Street, Suite 2035,
North Andover, MA 01845 Phone: 978.685.9540 Fax: 978.688.84"76
1
TOWN OF NORTI NI.)C.)VEI
Office o1 CC MMLJN1 Y I:)EVI,LOPMENT NI) SIB IMC1 S
FlEALTH DEPARTMENT
1600 OSG()OD STREET; SI1I'IE 2035
Nl7U'll Nf)O\,'[-' , MASSAO]USE"l TS 01845
Susan Y.Sawyer, REHS/RS 978.68K9540 Phone
978.688.8476 -€A
Public Health Director E-MAIL: IteSal tltcic�(%�tt��vttc>1;t2catt[t¢trtci
W1
11 B S1"]1 1 L littIL0 �wnf.taNvn()lltrai tli iii over(G)ttI
SEPTIC PLAN SUBMITTAL FORM
Date of Submission: 6 // 0 / l
Site Location: 002 Boxford Street Lot 2
Engineer: Christiansen & Sergi, Inc.
New Plans? Yes $225/Plan Check# (includes 15`submission and one re-
review only)
Revised Plans?Yes x $75/Plan Check#
Site Evaluation Forms Included? Yes No x
Local Upgrade Form Included? Yes No x
Telephone M 978-373-0310 Fax#:
E-mail: Phil @csi-engr.com
Homeowner 4.
Name: S&L Homes LLC
OFFICE USE ONLY
When the submission is complete (including check):
➢ Date stamp plans and letter
➢ d Complete and attach Receipt
A t Copy File; Forward to Consultant
➢ I„ Enter on Log Sheet and Database
1
i
C * CHRISTIANSEN & 1
S1 PROFESSIONAL ENGINEERS AND LAND SURVEYORS
F INC
I
160 SUMMER STREET, HAVERHILL, MA 01830
i
I
Owner's Certification for 602 Boston Street Lot 2
I, William Lombard, the owner of record of 602 Boston Street Lot 2, hereby certify to the
following:
1. I have been provided a copy of the Title 5 Innovative Alternative Technology
Approval for General use dated 2/19/2015 , the Owner's Manual with
maintenance , and I agree to comply with all terms and conditions;
2. The design does not provide for the use of garbage grinders. This restriction is
understood and accepted;
3. Whether or not covered by warranty, I understand the requirement to repair,
replace, modify or take any other action as required by the Department or the
North Andover Board of Health (NABOH), if the Department or the NABOH
determines the system to be failing to protect public health and safety and the
environment, as defined in 310 CMR 15.303.
Acknowledged:
William Lombard
S&L Homes, LLC
i
i
PROFESSIONAL ENGINEERS AND LANG)SURVEYORS
C51 160 SUMMER STREET,HAVERHILL, NIA 01830
kel: 978-373-0310 www.csi-engr.com fax 078-372-3960
June 10 2015
North Andover Health Department
1600 Osgood Street, Suite 2035
North Andover,MA 01845
RE: Subsurface Sewage Disposal System for 602 Boxford Street—Lot 2
(Map 105C, Lot 22)
Dear Ms. Grant:
The above referenced Septic System Design was approved April 13, 2015..
The lot has been sold and the new owner has changed the house design and location. The septic
system design has been modified to reflect the same.
Should you have any questions,please do not hesitate to call me.
Si er ,nom
P :" luistiansen.
i
I
i
Blackburn, Lisa
From: Blackburn, Lisa
Sent: Thursday,June lI, 2015 2l5 PM
To: Dan Otbenheimer;Isaac Rows; Pam Lally
Cc: Grant, Michele
Subject: FVV: 8DXFORD STREET |OT2
Attachments: LOT PROOF PLAN.pdf
602 BQxford St. lot 2 correct plans. |
Michele,
Stamped copies are in the file.
- -- - - - - - - - -
From: Lois Christiansen
Sent: Thursday, June 11, 2015 8:15 AM
To: Blackburn, Lisa
Subject: BOXFORD STREET|OT2
Good morning,
Michele requested the proof plan be corrected for Lot 2.
| will deliver 3 original stamped copies later today.
Thanks,
Lois �
Lois Christiansen |
Christiansen & Sergi, Inc
!
160 Summer Street �
Haverhill, MA 01830
o78-3r3'O310 ext. 11 FAX:978-372-3960
�
�
1
i
PROFESSIONAL, ENGINEERS AND LAND SURVEYORS
160 SUMMER STREET,HAVERHILL, MA 01830
tel:978-373-0310 www.csi-engr.com fax 978-372-3060
April 8, 2015
North Andover Health Department r
1600 Osgood Street, Suite 2035
North Andover, MA 01845 tttt
i
.�
RE: Subsurface Sewage Disposal System for 602 Boxford Street— Lot 2
Dear Ms. Grant:
I have reviewed your comments on the above referenced Sewage Disposal System and offer the
following responses: For ease in review, my comments are printed in blue.
1. Until the new address is provided by the Assessor's office please
indicate the address as "602 Boxford Street-Lot 2". This same
numbering system should be used for all proposed lots in the
subdivision. "I'lie new address ID has been added to the plan.
2. The design plan was not stamped and signed by the designer (3 10 CMR 15.220(2)). .A
stamped original was provided to the S A11011 with the original subniittal.
3. On sheet 1 of 2, the survey statement was not signed (NA 32). A signed original was
provided to (lie NAB OH with.the original SUbIllittal.
4. Itis unclear if the proposed driveway will be an impervious
area(310 CMR 15.220(4)(d)). The I ote "asphalt" has
been added to the site plan.
5. On sheet 1 of 2, the conventional system (proof plan) should be shown
on the site plan to confirm the location meets the required setback
distances. 1't.00f`plan has been put on a site plan.
6. A manhole is required at the 90 degree bend in the building
sewer line (310 CMR 15.222(8)). The design. has been revised to
omit the 90" turn,
7. On sheet 1 of 2, the depiction of the pipe going through the
septic tank should be removed. Pipe has been ren oved,
8. The manufacturer was not indicated for the septic tank (NA 3.2).
However, if it is assumed that the manufacturer is SHEA concrete,
the model number indicated on the design plan does not reference a
.monolithic septic tank. The proper model number has been added to
the plain.
9. On sheet 1 of 2, the water line from the well to the proposed dwelling should be depicted.
The line has been added.
10.On sheet 2 of 2, the distribution box detail depicts a 2" sump. A
minimum 6" sump is required (3 10 CMR 15.232(3)(e)). The 6"
stltnP is trotCd 01-1 t1Te 111,111
11.On sheet 2 of 2, the schedule of elevations and the profile indicate
no slope from the outlet of the distribution box to the inlet of the
Infiltrator Chamber trenches. That is correct, It is the desi,n,er s
irrt��nt.
12.The breakout elevation should be indicated clearly on the design
plan to assist the installer. Tile l:WeaIIWLrt eievatdOtl is s11owra or) the
cross Section.
13. Indicate the material of the proposed manhole covers above the septic
tank and indicate the material and size of the manhole cover proposed
above the distribution box. The iaterial and size is riven on sheet 2.
14. Since the Infiltrator Chamber system is proposed as an alternative soil
absorption system the "Standard Conditions for Alternative Soil
Absorption Systems with General Use Certification and/or Approved
for Remedial Use" will apply. Please provide the following as required
by the approval conditions Cet-tilications added to plan and copies of
0wtrers(10eLknients attached,
Section 11(18):
a) proof that the Designer has satisfactorily completed any
required training by the Contparxyfor the design and
installation of the Technology; No training is required.
c) certification by the Designer that the design conforms to
the Approval, any Company Design Guidance, and 310
CMR 15.000; and C"errtific°atiorr is on sheet 2.
d) a certification, signed by the Owner of record for theproperty
to be senl ed by the Technology, stating that theproperty
Owner:
1, has been provided a copy of'the Title 5 E
technology Approval, the Owner's Manual, and
the Operation and Maintenance Manual, and the
Owner agrees to comply with all terns and
conditions;
2, for Systems installed under a Remedial Use
Approval, the owner agrees tofid ill his
responsibilities toprovide a Deed Notice as
required by 310 CMR 15.287(10)and the
Approval;
3, for Systems installed tinder a Remedial Use
Approval, the owner agrees tofit ill his
responsibilities toprovide written notification of
the Approval to any new Owner, as required by
310 CMR 15.287(5);
4. If the design does notprovide for the use of
garbage grinders, the restriction is understood
and accepted; and
5, whether or not covered by a. warranty, the System
i
I
Owner inrderstands the regnirenient to repair,
replace, iiioclifi� or take arty other- action cis
required by the Departinent or the LAA, if the
Depar°tinerrt or the LAA deterirtirtes the Systeiii to
befailirig to
protect puhlic health acrd safety and the
envirolwient, cis defined iii 310 CUR .15.303.
Copies crt`above iii'e attached,
Should you have any questions,please do not hesitate to call me.
Sin ly
Christiansen.