Loading...
HomeMy WebLinkAboutMiscellaneous - 303 BERRY STREET 1/4/2016 Commonwealth of Massachusetts Map-Block-Lot 108.CO063 BOARD OF HEALTH ----------------------- Permit No North Andover BHP-2013-0999 ----------------------- FEE $250.00 ----------------------- DISPOSAL WORKS CONSTRUCTION PERMIT Permission is hereby granted Arco-Excavatorsjn-c------------------------------------------------------------------------------ to(Repair)an Individual Sewage Disposal System. at No 303 BERRY STREET - ------------------------------------------------ -------------------------------------------------------------------- as shown on the application for Disposal Works Construction Permit No. BEP-2013-099 Dated October 28,2013 ----------------------- ------------------------------ - ------------------------------------------ ---------------------- -Issued ssued On:--Oct-28-2013- - -------------------------------------------------- BOARD OF HEALTH Application for Septic Disposal System TODAY'S DATE s Construction Permit — TOWN OF ORTH ANDOVER, MA 01845 $2SO.0O-Full Repair $12S.0O 'Component SAC USN Important: Application is hereby made for a permit to: When filling out E] - new 'aibasoxvmQedisposal ayab*m^ mrmoonthe Construct- computer,use Repair nr replace on existing on-site eevvoQedisposal system*on|ymom key -- m move your F-1 Repair or replace an existing system component-What? cursor do not use the return | A. Facility Information VQ 7, xoy� ' '� 2.-*TYPE : El �*—'u copy ' m|ecthno| permit to application*** [] Conventional System (pipe and stone system) ro�-fi|tratororB|mdiffusmr(Greve|-Leao)yNtaohacopyofyuuroedi#uation0oinstaUMhietypoo[oystom. F1 Pressure Distribution S.A.S. (No D-Box) (Attach Draft Maintenance Agreement) PreeeunaOoemd (D'8��Pnaemn��.A.�. \ � 3. Owner Information Name r Address(if different from above) | City/Town State Zip Code � Teleph)ne Number | Name Name of Company Address _ Installer Information ` cKy/Tvwn State Zip Code Telephone Number(Cell Phone#ff possible please) 4. Designer Information Name Name of Company Addr City/Town State Zip Code Application for Disposal System Construction Permit^Page 1nfz 0* oRrs4 Application for Septic Disposal System TODAY'S DATE 40' Construction Permit - TOWN OF $ 250.00-Full Repair ORTH ANDOVER, MA 01845 $125.00-Component PAGE 2 OF 2 A. Facility Information continued.... 5. Type of Building: Residential Dwelling or❑Commercial B. Agreement The undersigned agrees to ensure the construction and maintenance of the afore-described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code,as well as the Local Subsurface Disposal Regulations for the Town of North Andover, and not to place the system in operation until a Certificate of Compliance has been issued by this Board of Health. Z4 Name Date Application Approved By: (Board of Health Representative) Name Date Application Disapproved for the following reasons: For Office Use Only: L Fee Attached? Yes No 2. Project Manager Obligation Form Attached? Yes No 3. Pump System? If so,Attach copy ofElectrical Permit Yes No 4. Foundation As-Built?(new construction ronly): Yes No (Same scale as approved plan) 9. Floor Plans?(new construction only): Yes No Application for Disposal System Construction Permit•Page 2 of 2 i Sawyer, Susan J From: Jack Sullivan <jacksullS3 @comcast.net> Sent: Monday, October 28, 2013 12:17 PM To: Sawyer, Susan Cc: Grant, Michele;Arco (arcoex @comcast.net) Subject: Re: 303 Berry Street, NA-Additonal building sewer to Septic Tank Attachments: 303Berry_NewSewerLine.pdf Susan & others, The owner of 303 Berry Street is looking to run the sewer service from the recently constructed addition on the OUTSIDE of the foundation to the proposed septic system. Originally the sewer service for the addition was going to be tied into the existing building sewer...but due to a finished basement this would be problematic. Attached is a red line portion of the plan showing how the proposed sewer line from addition will run to the proposed septic tank. Invert elevations are shown, pipe type, length, slope are shown. I also turned the proposed septic tank 90 degrees to better receive the 2 building sewers now coming into the tank. I will reflect these changes on the as-built plan as well. ALL other aspects of the approved septic plan have not changed. Jack Sullivan 978-352-7871 Please note the Massachusetts Secretary of State's office has determined that most em more ails to and from municipal offices and officials are public records.For information please refer to:http://www,sec,state.ma.us/p e/ reidx.htm. Please consider the environment before printing this email. i 1 i i Sawyer, Susan From: Jack Sullivan <jacksu1153 @comcast.net> Sent: Thursday, October 31, 2013 9:00 AM j To: Sawyer, Susan 3 Cc: Grant, Michele;Arco (arcoex @comcast.net) Subject: Re: 303 Berry Street, NA Hi Susan + Michelle, On my design plan I had left 6" of spacing between infiltrator units which was not needed (I leave 6" of spacing when I design drainage fields). I corrected this when I laid the field out for Arco. I know someone just did the bottom of bed inspection and Tom called saying you may have a question on the spacing. Hope that explains the difference. Since this site is so tight with setbacks to the well, wetlands, and property line the elimination of the 6" spacing between units helped out. I will reflect this change on the As—Built plan. Thanks. Jack Sullivan 978-352-7871 From: "Jack Sullivan" <iacksu1153 comcast.net> To: "Susan Sawyer" <ssawyeratownofnorthandover.com> Cc: "Michele Grant" <m rant(`atownofnorthandover.com>, "Arco ( rcoexCa,com cast.net)" <arcoex(a@comcast.net> Sent: Monday, October 28, 2013 12:17:20 PM Subject: Re: 303 Berry Street, NA -Additonal building sewer to Septic Tank Susan & others, The owner of 303 Berry Street is looking to run the sewer service from the recently constructed addition on the OUTSIDE of the foundation to the proposed septic system. Originally the sewer service for the addition was going to be tied into the existing building sewer...but due to a finished basement this would be problematic. Attached is a red line portion of the plan showing how the proposed sewer line from addition will run to the proposed septic tank. Invert elevations are shown, pipe type, length, slope are shown. I also turned the proposed septic tank 90 degrees to better receive the 2 building sewers now coming into the tank. will reflect these changes on the as-built plan as well. ALL other aspects of the approved septic plan have not changed. Jack Sullivan 978-352-7871 i i Grassed Prop, Deck Area Extension / N15, 20 BY WPI PROP. SILT SOCK 15, 2013 4i�1,, s$, 76' _ _ - �► 12" DIAME R (TYP) '00. �J 7 oR 4P 6' AL _J ° 6 �To R�eck APProxir 00 LO �j' 18 0' �n� Service 39' St f ® o Be Rernov To q� aOD ea, lg �N PROP. 1�,s`ro >�-�`� EX r r A 17 r oQ TOF-=I o0r.o®N ,,. WOOD F2 S7-oR y 94 / BSM,,T��j2.3'/8, S7RUC�RME 3ARRIER PROP. FOUNDATION ® ` 18.0' r 2, IMETER DRAIN ` ® V ------ X5.75 TO ECT TO ® In v-- 8) l 91.75' DRYWELL 23' 18" 97 6' /Grossed F SYSTEM 1 02.7' 4" 20/. Prop pp- L 3,2.0' 3��w2 W°Ikw Fini d Gr �' 04' 97 16' EX. 100 FOOT WELL ' PROTECTION RADIUS (95x67) , 2 T- `,epti S(RV�OC1E Prop. 18" Wide x 4" Deep Grassed Swale LIMIT OF 5 FOOT OVERDIG (TYP) 97x67 / FILL MATERIAL TO MEET SPECIFICATION IN SECTION 15.255(3) OF TITLE 5 CODE r U a. (9$ ' OF INFIL IRA TOR UNI IS (42 UNI IS TO TA L) LUS STANDARD LP 10D ER ZONE ��� ASS 1~ OvFF INSPECTION PORT TO WITHIN 6 3" OF FINISHED GRADE (TYP) �2s F LEVATIONS AND TIES SHOWN ON THIS fUAL SURVEY MADE ON THE GROUND. EX. SEPTIC TANK TO BE PUMPED OF CONTENTS AND DECOMMISSIONED IN ACCORDANCE WITH TITLE 5 REGULATIONS DATE APPROXIMATE LOCATION OF EX. SEPTIC LEACHING PITS (3 TOTAL). CONTRACTOR TO REMOVE ANY ENCOUNTERED PITS TO THE LIMIT OF THE 5 FOOT OVERDIG AND FILL VOID WITH TITLE 5 SAND 1 1 J � • 1 � ��'C'fLGD I�yx ♦ ( ,� r / � 1 • I ti � ' nr lid`„naM�nnrrl� � 11 i North Andover Health Department (ommunity Development Division August 5, 2013 John Sullivan, P.E. 22 Mount Vernon Road Boxford, MA 01921 Re: Subsurface Sewage Disposal System Plan for 303 Berry Street (Map 38,Lot 34) Dear Mr. Sullivan: The proposed wastewater system design plan for the above site dated July 22, 2013 and received on July 25, 2013 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. '�°' 1 do. A scaled profile of the system is required (NA 3.2). On Sheet 1 of 2, please depict the location of the percolation test (3 10 CMR 15.220(4)(1)) P,--"3- , 3• On Sheet 1 of 2,please depict the location of the water line (3 10 CMR 15.220(4)(m)). On Sheet 2 of 2, please depict the required depths of the inlet and outlet tees in the septic V--5.�' tank (3 10 CMR 15.227(6)). It appears an effluent filter is being proposed according to note#18 under General Notes. Please indicate the DEP approved brand and model. A manhole cover to finish grade will Itlso be required above the outlet with an effluent filter(3 10 CMR 15.227(7)). appears the bottom of the septic tank elevation (92.58) is below the ESHWT of 90.93. lease provide buoyancy calculations (3 10 CMR 15.221(8)). 7. Please provide a note that the septic tank shall be watertight(3 10 CMR 15.221(1)). !�Please provide a note that the outlet pipes of the distribution box shall be laid level for the first 2 feet (3 10 CMR 15.232(3)(c)). There should be a minimum of 9 inches of cover material above the top of the distribution box. There appears to be approximately 5 inches based on a proposed spot elevation of 96.7 and a top of distribution box elevation of 96.28. If the distribution box will have a greater than 9 inches of cover material please provide a riser in accordance with(3 10 CMR 15.232(3)(0). Page 1 of 3 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 10. A percolation rate of 16 mins/inch should be used for the design calculations instead of 15 mins/inch. The percolation test had a recorded time of 46 minutes for the water level to drop from 9 inches to 6 inches. A copy of the Board of Health representative's field r notes are included for reference. Based on a percolation rate of 16 mins/inch the loading rate should be 0.53 gpd/sf instead of 0.56 gpd/sf. Please modify the design plan ordingly. On Sheet 1 of 2, the proposed grading is within 5 feet of the property line therefore a ,- ' swale should be proposed (310 CMR 15.255(2)). 12. On Sheet 1 of 2, the proposed grading between the 98 and 100 contour is not a 3:1 slope. 3. On Sheet 2 of 2,please indicate the depth and layers of removal below the proposed leach field. 14. Please reference the appropriate document that specifies the allowance of crushed stone between the Infiltrator Chambers. 15. Since the Infiltrator Chamber system is proposed as an alternative soil absorption system the "Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved for Remedial Use"will apply. Please provide the l following as required by the approval conditions Section II(18): - proof that the Designer has satisfactorily completed any required training by the Company for the design and installation of the Technology; - certification by the Designer that the design conforms to the Approval, any Company Design Guidance, and 310 CMR 15.000; and - a certification, signed by the Owner of record for the property to be served by the Technology, stating that the property Owner: 1. has been provided a copy of the Title 5 EA technology Approval, the Owner's Manual, and the Operation and Maintenance Manual, and the Owner agrees to comply with all terms and conditions, 2. for Systems installed under a Remedial Use Approval, the owner agrees to fidfdl his responsibilities to provide a Deed Notice as required by 310 CMR 15.287(10) and the Approval; 3. for Systems installed under a Remedial Use Approval, the owner agrees to fulfill his responsibilities to provide written notification of the Approval to any new Owner, as required by 310 CMR 15.287(5); 4. if the design does not provide for the use of garbage grinders, the restriction is understood and accepted; and 5. whether or not covered by a warranty, the System Owner understands the requirement to repair, replace, modify or take any other action cis required by the Department or the LAA, if the Department or the LAA determines the System to be failing to protect public health and safety and the environment, as defined in 310 CMR 15.303, Page 2 of 3 North Andover 1-Iealt1i Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 16. A deed notice will need to be recorded prior to construction in accordance with Section IV of"Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved for Remedial Use". 17. In accordance with Section 11(7) of"Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved for Remedial Use",please provide a best feasible upgrade plan. Please feel free to contact the office with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. ,S,mcerel Susan Y. S er HS/RS Public Health Director Page 3 of 3 North Andover tlealth Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 1 f C F l � __A f� it 37-/x_ l f