Gerald Brown, Inspector of Buildings May 7, 2014
To:Curt Bellavance
Fr: Gerald Brown
Re: 1600 Osgood Street—ACT Theatre
Per your inquiry regarding needed parking spaces for the proposed ACT Theatre at 1600 Osgood
Street in North Andover, MA the following is needed based on the Zoning Bylaw Section 17.10 Parking
Requirements. Based on the bylaw there must be one (1) parking space per four(4) persons based on
the design capacity of the facility. Per the Architect's plan the occupant load for the theatre(seating) is
235,so the parking needed for the proposed ACT Theatre is 59 spaces.
The zoning usage for 1600 Osgood Street is in the 12 Osgood Smart Growth district so the
proposed ACT Theatre application would need to apply for a special permit according to the Zoning
Bylaw Section 17.6.2.3. uses allowed by special permit,#11—Indoor Place of Amusement or Assembly.
Gerald Brown
Inspector of Buildings
surface treatments for sidewalks and other hard surfaces (such as pavers, cobblestones or concrete
surface treatments designed to resemble pavers or cobblestones), and similar objects shall not be
considered obstructions. No more than 25% of the total amount of required Usable Open Space
shall be "wetland" as defined by the requirements of M.G.L. Chapter 131, Section 40, and the
Town's Wetland Bylaws.
17.10' Parking Requirements
Notwithstanding anything to the contrary in this Zoning Bylaw,the parking requirements applicable in the
OSGOD are as follows:
�12csrdentialUses - = --
I Residential Use(Minimum) 1 space per dwelling unit.
2 Residential Use(Maximum) 2 spaces per dwelling unit.
All other places tivith including(but not limited to)rooming 1 space per sleeping room for accommodations single or double occupancy,
3 houses,hotels,motels,hospitals,nursing homes. 1 per 2 for rooms exceeding Double beds for rooms exceeding double
occupancy
RecrcahonUses =
1 K.ssive Recreation(i.e.parks,picnic facilities) 5 spaces per acre.
2 JActive Recreation(i.e.athletic fields) 1 space per 4 persons based on the design capacity of the facility.
_ :, Busme3s or_Commercial Tlses
Auditoriums,theaters,funeral parlors,day care centers,and
+ � 1 I space per 4 persons based on the design capacity of the facility.
Q/ other places of assembly
2 Restaurants-sit down restaurants. 1 per 2 seats or 15 per 1000 GFA.(Whichever greater applies)
3 Retail store and service establishement. 5 spaces per 1,000 square feet(6 space per 1,000 s.f.maximum)
4 Offices 1 space per 300 square feet of GFA.
5 Medical Offices and Research facilities 3 Spaces per 1000 square feet GFA plus one space per employee.
6 Warehousing,wholesaling,distributing I space per 500 square feet GFA.
7yLxedUseDcvelo�igcntProjects Residential requirement plus non-residential requirement.
' 7Industnal'rUscs
I space per 2 employees in the minimum working shift or 1 space per 1,000
I Manufacturing,assembly,Fabrication,etc GFA(Whichever greater applies).
17.10.1 Interpretation of Table.
1. Unless otherwise approved by the PAA, a minimum of 1 and a maximum of 2.0 off- street parking
spaces shall be provided for each residential unit,inclusive of parking spaces within garages. The
PAA may allow for additional visitor parking spaces beyond the 2.0 maximum spaces per unit if
deemed appropriate given the design, layout and density of the proposed residential or other
development. The PAA may allow for a decrease in the required parking as provided in
Subsections 4.a through 4.f below. Notwithstanding anything to the contrary herein, an Applicant
may satisfy the parking requirements herein'even though parking may not be located within the
same Subdistrict as the specific use, provided that suitable arrangements to the satisfaction of the
PAA are in place to allow for the use of such parking to satisfy the parking requirement;
2. A parking space shall mean an area of not less than 9' x 18', accessible over unobstructed
driveways not less than 24'wide.
3. Notwithstanding anything to the contrary herein, the use of shared parking to fulfill parking
173
IUD
/ o
STAGE I�TRX
MMON AREA i /T
;STORAGE
El
1I1E'(��++
Jt El
Ll
ED El 11
D El
® � El DO' � 0 � L
� r� � �l � r-,, � nom ® ® /
1
I jI
H I
1
I
I
TENANT SPAOEC a H
I
I
I
1
I
I
,,III]
11111
Lu1Lu
9983 SQUARE FEET ASSEMBLY Al 19883 SQUARE FEET
Al ASSEMBLY - STAG SEATING FOR 249 Al ASSEMBLY - L0513Y
OLF 15 Sk/OCG NON-SIMULTANEOUS USE OLF 5 SF/OGG
NON-SIMULTANI=0U6 USE
OCCUPANT LOAD FACT®R5 OCCUPANT L®AD5
ASSEMBLY - Al STAGE 11 OCCUPANTS
STAGE 15 SQUARE FEET PER OCCUPANT SEATS 235 OCCUPANTS ,
L.O55Y 5 SQUARE FEET PER OCCUPANT
LOBBY 431 OCCUPANTS
BUSINESS OFFICE 2 OCCUPANTS
OFFICE 100 SQUARE FEET PER OCCUPANT
CLASSROOM 30 OCCUPANTS
EDUCATIONAL WORKSHOP 23 OCCUPANTS
CLA56ROOM 20 SQUARE FEET PER OCCUPANT
WORKSHOP 50 SQUARE FEET PER OCCUPANT STORAGE 3 OCCUPANTS
STORAGE 300 SQUARE FEET PER OCCUPANT 861 TOTAL OCCUPANTS
EXIT
EXIT CAPACITY LEGEND:
LEASE LINE 5HOU.N A& a
AREA CA L C U L AT I®N 5 PATH OF EGRESS SHOWN AS:
NO OBSTRUCTION 15 t0 BE PLACED WITt4-IN TI4E PATH,
LEASE AREA 69121 SQUARE FEET
ILLUMINATED EXIT SIGN
TOTAL BUILDING SHOWN A&
FOOTPRINT 1`1,1058 SQUARE FEET -- SON `�1� `