HomeMy WebLinkAboutMiscellaneous - 26 STANTON WAY 1/19/2016 (3) I 1, INC. CS111 PROFESSIONAL ENGINEERS AND LAND SURVEYORS 160 SUMMER STREET,HAVERHILL,MA 01830 tel:978-373-0310 www.csi-engr.com fax 978-372-3960 j I June 19, 2013 r Ms. Susan Sawyer Public Health Directory (,) North Andover Health Dept. 1600 Osgood Street, Suite 2035 North Andover, MA 01845 Re: Subsurface Sewage Disposal System Plan for Lot 16-8 Saracusa Way (Map 61, Lot 16-8) Dear Ms. Sawyer: We have revised the plan to address your 6/10/2013 comments. To facilitate the review of this information we have reproduced your comments, and our responses follow each comment in blue italics. 1. Please reference the Lake Cochichewick watershed in the notes on sheet 2 (NA 3.2). (Note 16 on Sheet 2 has been revised accordingly.) 2. Please demonstrate that a conventional system in compliance with 310 CMR 15.000 can be built on the site in order to use the Infiltrator Chamber system according to Section 1(3) of the DEP General Use approval letter. An outline and brief description of a conventional system on the site plan is sufficient. (The proof plan and associated calculations have been added to Sheet 1.) 3. Please depict the percolation tests on the site plan (310 CMR 15.220(4)(i)). (The Perc Test locations have been added to the Site Plan on Sheet 1.) 4. TP-40 was recorded with weeping water at 100"and the A layer extended to 9". A copy of the Board of Health representative's field notes are enclosed for reference. (The soil log for TP 40 has been revised to include the missing data.) 5. Please add a note to the plan to indicate that a riser to within 6 inches of finish grade is required above the distribution box if greater than 9 inches below grade. (Note 5 has been added to the Distribution Box Detail on Sheet 2 to include this requirement.) 6. Please indicate the model/brands of the septic tank and distribution box(NA 3.2). (The manufacturer and model numbers of the septic tank and distribution box have been added to the details on Sheet 2.) 7. Please indicate the holder of the shared driveway easements located on the lot(310 CMR 15.220(4)(c)). (The owners of Lots 16-7 and 16-8 will be the holders of the easement. General Note 18 has been added to Sheet 2 to include this information.) 8. The D-Box does not have a 2"drop between the inlet and outlets. It appears to be a misprint but please modify accordingly. (The invert elevation of the outlet pipe has been revised to provide the required 2"drop.) 1 June 19,2013 1 I trust that this response and the revisions made to the plan fully address all of your comments. Please contact me if you have any questions. t Very truly yours, Christiansen & Sergi, Inc. Philip G. Christiansen • Page 2 u� tV w n 00 Z5g' 'd Void f ___ -____ W Q cG Wes € E49R °L)z> gU Z J \, o —2?�li> lip 1 o , r 3 E _ _ a ,jam g � �* 8 �a uj CL uj o " U IF c o N'I U o u vn HEM, iP »x HD LL PE m LL 7 e goo w 111hil awny sm H: I WIR Hit mgm IUNH 11m. lul 110 flu Mn R 1 1 MN 2 I!H 118 D11 HUM 0< I ME 51 1 Hill M I Ion ! , lull u fl I (I 111W Ujiv ws9 i N EL-T M sg'g NI H 011 i L-SH ?;H . HN M11 11 ill i 1 11 1 1 Og 0 w IN �7 M M AY w HUES (1) U) -a 81 HE !I d PLO. 5 oil 95, H 'ro Lo,I w �jq H UH n 1p H I"I 1 1 g p UN Rim U His .11 j ado Wn� gun HIN pig U SUR R H )Intl 1€ a H SIM II URI l 1 North Andover Health Department Community Development Division June 10, 2013 i Philip Christiansen, P.E. Christiansen and Sergi, Inc. 160 Summer Street Haverhill, MA 01830 Re: Subsurface Sewage Disposal System Plan for Lot 16-8 Saracusa Way (Map 61,Lot 16-8) Dear Mr. Christiansen, The proposed wastewater system design plan for the above site dated April 29, 2013 and received on May 3, 2013 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item. 1. Please reference the Lake Cochichewick watershed in the notes on sheet 2 (NA 3.2). 2. Please demonstrate that a conventional system in compliance with 310 CMR 15.000 can be built on the site in order to use the Infiltrator Chamber system according to Section 1(3) of the DEP General Use approval letter. An outline and brief description of a conventional system on the site plan is sufficient. 3. Please depict the percolation tests on the site plan(3 10 CMR 15.220(4)(i)). 4. TP-40 was recorded with weeping water at 100" and the A layer extended to 9". A copy of the Board of Health representative's field notes are enclosed for reference. 5. Please add a note to the plan to indicate that a riser to within 6 inches of finish grade is required above the distribution box if greater than 9 inches below grade. 6. Please indicate the model/brands of the septic tank and distribution box (NA 3.2). 7. Please indicate the holder of the shared driveway easements located on the lot(3 10 CMR 15.220(4)(c)) Page 1 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01.845 Phone: 978.688.9540 Fax: 978,688.8476 i 8. The D-Box does not have a 2" drop between the inlet and outlets. It appears to be a misprint but please modify accordingly. Please feel free to contact the office with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sinc r y, Susan Y awy , REHS/RS Public Health Director cc: Green & Company File i Page 2 of 2 North Andover -lea➢th Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01 845 Phone: 97 .6 . 540 Fax: 978.688.8476 I I � 1 North Andover Health Department Community Development Division November 4,2014 New Homeowner 26 Stanton Way North Andover, MA 01 845 Re: Your new home and your 4-bedroom septic system Dear Resident, Congratulations on your move to North Andover and on your new home. The North Andover Health Department has overseen the design approvals and installation of the septic system on your property and believes that it is important that you understand the details of the system that services your home. Enclosed is information on how to care for your septic system and notification of restrictions in case you intend on finishing additional spaces, which are currently designated as "unfinished space", in your home. The house plans that were submitted prior to construction of your home show multiple unfinished areas, but this system can only serve a 4-bedroom home (maximum 9-room). A home with this sized system,which as defined by the MA Department of Protection regulations 310 CMR 15.000,will have a maximum of a 9 rooms in total (not including bathrooms; laundry rooms etc). Therefore, according to our file, your home is currently at its maximum capacity in room number. This assumes you did not finish more than the plans originally identified. If you have gone over the approved number, a violation to MA DEP code may already exist. The multiple unfinished areas in your home are allowed by state code and are not counted until finished. The inclusion of this amount of square footage, as unfinished space, was discussed with your builder. The Green Co. chose to inform homeowners upon purchase,that if you plan on finishing any of the areas for living space, above the 9-rooms, the expansion of the septic system and the compliance with the code will be done by the new homeowner. No building permits,to finish additional rooms, will be supported unless compliance is achieved. If at any time you do plan to inhabit any of these multiple unfinished areas,please contact our office and we will be happy to discuss the options with you. Page 1 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 26 Stanton Way November 4, 2014 As the homeowner, we want you to be fully informed on how disposal systems work. The document provided will help you care for your system. You can also access numerous guides to assist you on the MA DEP website, http://www.mass.gov/eea/agencies/massdep/that will help you maintain your system in good working order, so it will protect you and the environment for many years to come. Finally, it is important to note that this septic system is not designed for use with a garbage grinder. Installation of a garbage grinder will cause damage to your septic system and will void any guarantees for its proper service by the septic installer from the date you install the grinder. We hope you are enjoying your new home in North Andover. The Health Department staff members are here to answer your questions on septic systems or any other Public Health related subject. Feel free to contact us. Sincer ly, a 7 e , S/RS ublicHeaal rector Encl. "Caring for your Septic System: A Reference Guide for Homeowners" Page 2 of 2 North Andover Health Department, 1600 Osgood Street, Building 20, Suite 2-36, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688,8476 Caring for your Septic System | MouoI]EP Page [ of _ The Official*^bsim*the Executive Office*Energy and Environmental Affairs Energy and Environmental Affairs �EE**ome ' Agencies , MassDEP ` Water Resources ` wmwew"* xoeptic` Caring for Septic System:Reference Guide for Homeowner Caring for your Septic Systemm: A Reference Guide for Homeowners Caring for Your Septic System (Conventional Septic System,Innovative/Alternative(I/A)System,or Cesspool) Resources The accumulated solids in the bottom of the Septic tank should be pumped out every three years to prolong the life of your system.Septic systems must oo maintained regularly m stay working. w°m/°ct or abuse n,your system can cause um fail.Failing systems can ' cause a serious health threat m your family and neighbors, ' degrade the environment,especially lakes,streams and groundwater, ' reduce the value m your property, AmZ Quick Links |' ^ be very expensive mrepair, ' and,put thousand of water supply users at risk if you live in a public water supply watershed and fall to maintain your Water Resources Index /' system. ae alert m these warning signs mo failing system: ' sewage surfacing over the uramnem(especially after mvrms). ^ sewage back-ups m the house, ' lush,green growth over the oramnom. | 1 ^ slow,draining toilets or drains, ' sewage odors. | to distribution to � | Tips m Avoid Trouble DO have your tank pumped out and system inspected every omnyears byalicensed septic contractor(listed mthe yellow pages). DO keep a record of pumping,inspections,and other maintenance.Use the back page m this brochure to record maintenance dates. DO practice water conservation.Repair dripping faucets and leaking toilets,run washing machines and dishwashers only � when full,avoid long showers,and use water-saving features in faucets,shower heads and toilets. � DO learn the location of your septic system and drainfield.Keep a sketch of it handy for service visits.If your system has a flow diversion valve,learn its location,and turn it once a year.Flow diverters can add many years to the life of your system. DO divert roof drains and surface water from driveways and hillsides away from the septic system.Keep sump pumps and house fooling drains away from the septic system oawell, DO take leftover hazardous household chemicals to your approved hazardous waste collection center for disposal.Use bleach,disinfectants,and drain and toilet bowl cleaners sparingly and In accordance with product labels. DON'T allow anyone to drive or park over any part of the system,The area over the drainfield should be left undisturbed with only a mowed grass cover.Roots from nearby trees or shrubs may clog and damage your drain lines. hUn:// YT9w.Ioua8.gov/moa/og000ino/uzUGSdcD/Wnter/vvau[cT9otoD/c ' -for-aeptio-ayo1ozo-zef.. 11/4/2014 i i� i REAL ESTATE development ® commercial o residential ® brokerage Owner's Certification for Lot 16-8 Stanton Wa North Andover 1, Michael Green, on behalf of Cranfield Investments, LLC, the Owner of record of Lot 16-8 Stanton Way, hereby certify to the following: 1. 1 have been provided a copy of the Title 5 Innovative Alternative Technology Approval, the Owner's Manual, and the Operation and Maintenance Manual for the Infiltrator Wastewater Treatment System, and I agree to comply with all terms and conditions; 2. The design does not provide for the use of garbage grinders. This restriction is understood and accepted; 3. Whether or not covered by warranty, I understand the requirement to repair, replace, modify or take any other action as required by the Department or the Local Approving Authority (LAA), if the Department or the LAA determines the System to be failing to protect public health and safety and the environment, as defined in 310 CMR 15.303. Acknowledged: Michael Green I Green & Company all Lafayette Rd, Mail: P.O.Box 1297, North Hampton, NH 03862 8603.964.7572 1 1 I I I 16-3 STANTON WAY — EXISTING FND. ry EL.=96.0' N . i I EASEMENT i\ I ^ I I M LOT 16-4 33.3' I --------� � in 16-5 --- � m W BUFFER °- 239.7' OF MICHAEL J. SERGI 4Vcr.3319 I CERTIFY THAT THE PRIMARY STRUCTURE SHOWN CONFORMS TO FOUNDATION R 1 ' THE HORIZONTAL SETBACK REQUIREMENTS OF THE LOCAL A -BUILT LT (THISICERTIFICATION DOES NOT CONSIDER ANY OTTHERRUCTED. RESTRICTIONS SUCH AS COVENANTS,WETLANDS,EASEMENTS, ORDERS OF CONDITIONS,ETC.)THIS DRAWING SHALL NOT BE USED I �. GREEN p®p. �y ®���®a®' BY THE CLIENT FOR ANY PURPOSE OTHER THAN THAT OUTLINED ■V••�Fa\+C C �Xi.�, COMPANY Y ABOVE,EXCEPT WITH THE WRITTEN PERMISSION OF CHRISTIANSEN &SERGI INC.FURTHERMORE THIS DRAWING IS THE COPYRIGHTED THIS CERTIFICATION IS MADE AND LIMITED TO THE ABOVE CLIENT PROPERTY OF CHRISTIANSEN&SERGI INC.AND ANY UNAUTHORIZED USE IS PROHIBITED.CHRISTIANSEN&SERGI TAKES LOCATION: NORTH ANDOVER,MA. NO RESPONSIBILITY FOR THE UNAUTHORIZED USE OF THIS DRAWING OR ANY INFORMATION CONTAINED HEREON. DATE:6125/14 SCALE: 1"=100' PROFESSIONAL ENGINEERS & LAND SURVEYORS 160 SUMMER STREET, HAVERHILL, MASSACHUSETTS 01830 WWW.CSI-ENGR.COM TEL. 978-373-0310 FAX. 978-372-3960 DWG.NO.: 12007.001.012 Sawyer, Susan From: Sawyer, Susan Sent: Tuesday, May 27, 2014 10:25 AM To: michael @greenandcompany.com Cc: Grant, Michele; Blackburn, Lisa Subject: Lot 8 inquiry Attachments: 201405270957.pdf Good Morning Michael, I returned today from a week off and became aware of a situation at Stanton Way. My staff received inquiry regarding the property known as lot 8 Stanton Way. Specifically,the total number of rooms in the home and the flow capacity of the septic system.We were told that a realtor is representing this home as having 10 rooms; with the ability to expand to 11.The attached building sign off, as well as septic approval, identify this as a 4-bedroom (max 9-room) home. Please advise your realtor that you chose not to have a deed restriction and that they may not advertise the home in this manner as it is false representation.The caller was given this information as well. Thank you, Susan -----Original Message----- From: nom townofnorthandover.corr7 [mai Ito:noreply cetownofnorthandover.com] Sent:Tuesday, May 27, 2014 9:58 AM To:Sawyer, Susan Subject: Message from "ComDev-Health-Ricoh" This E-mail was sent from "ComDev-Health-Ricoh" (Aficio MP C3002). Scan Date: 05.27.2014 09:57:32 (-0400) Queries to: norerlownofnorthandover.com Please note the Massachusetts Secretary of State's office has determined that most emails to and from municipal offices and officials are public records. For more information please refer to: http://www.sec.state.ma.us/prelpreidx.htm. Please consider the environment before printing this email. 1