Loading...
HomeMy WebLinkAboutPlans - 106 MEADOWOOD ROAD 1/20/2016 TABLE OF CONTENTS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS rPAGESOLAR MODULESSYSTEM SIZE:424OW DC,3840WAC • ALLWORKSHALL COMPLYWITH 2014 NEC,2009 IBC,MUNICIPAL CODE,AND SE SERVICE ENTRANCEMODULES:(16)HANWHA Q-CELLS:Q.PRO BFR-G4265 ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. —RAIL SITE PLAN INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. LAYOUT (16)ENPHASE ENERGY:M250-60-2LL-S2X e ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MP MAIN PANEL r jRACKING:SNAPNRACK SERIES 100 UL;FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NOCONDUCTORS ARE SOLIDLY - — - ELECTRICAL SEE PEN D01. GROUNDED IN THE INVERTER.SYSTEMCOMPLIES WITH 690.35. . SIGNAGE • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUD-PANEL STANDOFFS& • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FOOTINGS • SNORACKING CONFORMS TO AND IS LISTED UNDER UL 2703. WGUARD REQUIRED. • SOLAREDGE RAPID SHUTDOWN REQUIRED. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E)AND 2012 LC PV LOAD CENTER I F CHIMNEY IFC 605.11.2. • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. ATTIC VENT ZN of • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ssq • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(a)&690.8(b)). PAUL K. FLUSH ATTIC VENT ZACHER PM DEDICATED PV METER PVC PIPE VENT TRUCTURAL 50100 INVERTERS)WITH C, METAL PIPE VENT INV INTEGRATED DC o isT DIS CONNECT AND AFCI deli T-VENT NAL AC O AC DISCONNECT(S) SATELLITE DISH For Structural Only EDC DISCONNECT(S) r/� FIRE SETBACKS CB COMBINERBOX '.� HARDSCAPE F—7 INTERIOR EQUIPMENT —PL— PROPERTY LINE meq.®��® L J SHOWN AS DASHED SCALE:NTS J V V q AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER LICENSE NO.750184 AZIM AZIMUTH VICINITY MAP COMP COMPOSITION ox,MA-.1DC DIRECT CURRENT (E) EXISTING �y EXT EXTERIOR CUSTOMER RESIDENCE: FIRM FRAMING ASI EN-WEN HSU a p,_. INT INTERIOR 106 MEADOWOOD RD,NORTH LBW LOAD BEARING WALL ANDOVER,MA,01845 tiA A - MAG MAGNETIC MSP MAIN SERVICE PANEL TEL 1506198zaeeo APNk:oz ao a, ,PpurA S's 100 (N) NEW PROJECT NUMBER: NTS NOT TO SCALE 222R-106HSU OC ON CENTER PRE-FAB PRE-FABRICATED DESIGNER: PST POUNDS PER SQUARE FOOT C.OEPOMO is^si PV PHOTOVOLTAIC - lws encadowoud wd TL TRANSFORMERLESS DRAFTER: TYP TYPICAL DI V VOLTS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET r m A REV:A 1/512016 fcei PAGE PV-1.0 PITCH TRUE MAG PV AREA AZIM AZIM (SOFT) SITE PLAN-SCALE=3132"=V-0" AR-01 36° 266° 280° 125.8 ® AR-02 36° 176° 190° 161.8 (E)RESIDENCE-- (N)ARRAY AR-01 PL P P Pi vi °L Pi a� n a J lJ q i [sunrun (N)ARRAY AR-02— LICENSE NO 7u01 $M.me9P / CUSTOMER RESIDENCE: HSIEN-WEN HSU 106 OVER,MEADM ,01 RD,NORTH � /I d ANDOVER,MA,01845 TEL.)888)982-498D APN m 025mW00 PROJECT NUMBER e� '4'OOQ 222R-106HSU M�Ppo 1H OFMgss DESIGNER: qC. C.OEPOMO e� PAUL K Z ]ZACHER DRAFTER: Il TRUCTURAL i DI 50100 NAU SHEETSITE PLANREV:A 1/5/20 PAGE PV-2.O ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SAN OVERHANG MODULES: AR-01 COMP SHINGLE FLASHED L FOOT.SEE PEN D01. TWO STORY ATTIC WOOD RAFTER 2 X 10 14'-S. 16" �Nlll"' 1'-4" HANWHA Q-CELLS:Q.PRO BFR- AR-02 COMP SHINGLE FLASHED L FOOT.SEE PEN D01. FIRST STORY VAULTED WOOD RAFTER 2X 10 10'-0" 16" " V-4" G4 265 MODULE DIMS: D1-AR-01-SCALE:1/4"=1' D2-AR-02-SCALE:114"=1' 65.7"x 39.4"x 1.26" PITCH:36" PITCH:36° MODULE CLAMPS: AZIM:266° AZIM:176° Portrait:9.84"-13.78" Landscape:0"-3.94" ® ® MAX DISTRIBUTED LOAD:3 PSF SNOW LOAD:50 PSF WIND SPEED: 100 MPH 3-SEC GUST. LAG SCREWS: 5/16"x3.5":2.5"MIN EMBEDMENT PENETRATION SPACING: STAGGERED r 6" 4 OFM1/4 4 TYP—f O PAUL K. ZACH R m TRUCTURAL w I "50100 I O )STE O O 0 O 0 O a SSS/ONA%- 5'6„ O 0 O O O O O 0 O sunrun 0-0 O 0 0 __ O 0 LICENSE NO.750184 7 3 eossze.smi "c.a",Mno�ee� i CUSTOMER RESIDENCE: -0 O 0.-� HSIEN-WEN HSU fl 106 MEADOWOOD RD,NORTH �. .—........ ....... ANDOVER,MA,01845 2'-6" ar.r—:ee s'AP"a,o _ PROJECT NUMBER: 5a-o 222R-106HSU DESIGNER: C.OEPOMO DRAFTER: DI SHEET LAYOUT REV:A 1/5/2016 PAGE PV-3.0 120/240 VAC SINGLE PHASE •MAX 16 MICRO-INVERTERS PER BRANCH CIRCUIT SERVICE e MULTIPLE BRANCH CIRCUITS IN PARALLEL METER#: •ENPHASE MULTI-PIN CONNECTORS--1 ST AC CONNECTOR AT NATIONAL GRID 12804613 EACH BRANCH CIRCUIT IS A SUITABLE.DISCONNECTING MEANS. M (N)60A ENPHASE .DO NOT DISCONNECT/CONNECT UNDER LOAD UTILITY AC COMBINER BOX GRID [WITH(3HANWHA LPRO )PRE-INSTALLED + f f f f �f/BFR6 4 5 MODULES EXISTING 20A PV BREAKERS AND ENPHASE ENERGY: (`iYl /l 200AMAIN ENVOY COMMUNICATION M250-60.2LL-S2X (\ BREAKER GATEWAY] i (9)HANWHA Q-CELLS: Q, RD BFR-G4 265 AND EXISTING MICRO-INVERTER PAIRS 200A — _ _ (1)BRANCH OF MAIN (N)LOCKABLE - (9)MICRO-INVERTERS FACILITY —PANEL BLADE TYPE (N)SUN RUN (1)BRANCH OF AC DISCONNECT METER JUNCTION Box ✓� ✓` `�' LOADS OR EQUIVALENT (7)MICRO-INVERTERS 20A PVNo SQUARE D 250V METER 20A BREAKER(A) BREAKER AT eon DU221RB SOCKET 20A BREAKER(B) OPPOSITE END 3R,30A,2P 125A CONTINUOUS OF BUSBAR 120/240VAC & 240VMETER 200A,FORM 2S CONDUIT SCHEDULE NOTES TO INSTALLER: 1. INSTALL NEW 60 AMP ENPHASE AC COMBINER BOX WITH(2)PRE-INSTALLED # CONDUIT CONDUCTOR NEUTRAL GROUND BREAKERS. w a■ �■. 1 NONE (2)12AWG AD ENGAGE CABLE (1)12 AWG ENGAGE CABLE (1)12 AWG ENGAGE CABLE 2.ADD 20 AMP PV BREAKER TO MAIN PANEL. PER BRANCH CIRCUIT Ps V V ER BRANCH CIRCUIT 2 P'EMT OR EQUIV. (4)10 AWG THHN/THWW2 (2)10 AWG THHN/THWN-2 (2)8 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10AWGTHHNITHWN-2 (1)8 AWG THHN/THWN-2 LICENSE NO,750184 MODULE CHARACTERISTICS CUSTOMER RESIDENCE: HANWHA Q-CELLS:Q.PRO 265 W HISIEN-WEN HSU BFR-G4 265 106 MEADOWOOD RD,NORTH OPEN CIRCUIT VOLTAGE 38.01 V ANDOVER,MA,01845 MAX POWER VOLTAGE 30.75V TEL,(508)912-4010 APN# SHORT CIRCUIT CURRENT 9.23A PROJECT NUMBER: 222R-106HSU DESIGNER: C.OEPOMO DRAFTER: DI SHEET ELECTRICAL REV:A 1/5/2016 PAGE PV-4.0 P PER R E I C 01tl�i LABEL LOCATION'. Im (CHU °M , ER CODE'.NEC690.13.G.38 NECLABEL LOCATION' 69 D,13e4 (AC)(POI) PER CODE:NEC690.13.8 THIS EpUiPMENT FED BV MULTIPLE SOURCE PER CODE:705.12(-)(2) TOTAL RATING OF OVER CURRENT DEVICES,EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED ® ® N AMPACITY OF BUSBAR ® "W 0 PER CODE:NEG690.56(C) ty N LABEL LOCATION (UNDER ROOFING: MATERIAL) PER CODE NEC690.13.G.1 LABEL LOCATION: dig LABEL LocnnoN: REM= =�OR. K HAZARD xwJ e PHDC)(INV)ER ONPO ER REI F TNIS : . (H USED PER CODE:NEC690.13.6 LAPOWEROIOINVERTER ARE ED PER CODE:NEC 690.15 AND NEC 690.13(6) BEENERGI— T L i (A)(POI)ATION'. PER CODE.NECfi90.13.3 LABEL LOCATION: LABEL LOCATIONTURN OFF PHOTOVOLTAIC IF)(AC)(CB) : (AC)(POI) AC DISCONNECT PRIOR TO PER CODE:NEC110.27(C) PER CODE.NC690.16.13 WORKING INSIDE PANEL ouu I n000uq � V`(' LABEL LOCATION: 9 6 0 ® 6A W Y 0 • LABEL LOCATION: (AC)(POI) (AC) II rvi PER CODENEC690.54 PER CODE'NEC690.33.E 2 ' Il 1111 I ,W- LABEL LocnrloN: ELECTRIC SHOCK HAZARD ABEL LOCATION: OO NOT TOUCH TERMINALS PER)CODE:NEC 690.17.E PER(INDCODE�NC7051VIDUABREAKE��) TERMINALS ON BOTH LINE AND 34 LOAD SIDES MAY BE ENERGIZED ������ ��/`L�'/ 1!511 11lOWYT44zL'/ IN THE OPEN POSITION OC VOLTAGE IS ALWAYS PRESENT " LABEL LOCATION' g' WH EN SOLAR MODULES ARE (DC)(INV) EXPOSED TO SUNLIGHT LICENSE NO.750184 PER CODE:NEC690.53 LABEL LOCATION: (DC)(INV) PER CODE:IFC.COA 1311`0 605,11.14 ixc.orv,Ma wear NEC 690.15,NEC 690.13(3)&NEC eos.sze.o'roi 690.14C.2. INVERTER OUTPUT CONNECTION LABEL LOCATION:POI) CUSTOMER RESIDENCE: DO NOT RELOCATE THIS PER CODE:NEC 705.12.-.2 HSIEN-WEN HSU OVERCURRENT DEVICE 106 MEADOWOOD RD,NORTH ANDOVER,MA,01845 TEL(508) 4:025 0 LABELLOCATION: PROJECT NUMBER: 0 LEGEND �. (Ac)PER CORE:690133 222R-106HSU (AC):AC Disconnect ELECTRIC SHOCK HAZARD LABEL LOCATION: (C):Conduit DO NOT TOUCH TERMINALS PER)CODE:NEC 690.17.E DESIGNER: TERMINALS ON BOTH LINE AN- C.OEPOMO (CB)Combiner Box 4 LOAD SIDES MAY BE ENERGIZED (D)Distribution Panel IN THE OPEN POSITION DRAFTER: (DC):DC Disconnect DI (IC):Interior Run Conduit (INV):Inverter with integrated DC disconnect SHEET (LC):Load Center SIGNAGE (M):Utility Meter (POI):Point of interconnection REV:A 1/5/2016 PAGE PV-5.0