Loading...
HomeMy WebLinkAboutCorrespondence - 163 MAIN STREET 10/25/2006 Steve Sullivan provided a certified under water recovery system it was submitted to Town Engineer, and site plan to Gerry Brown,proof from Steve Sullivan for Main St. insurance company Willis did a site visit and approved the project. 978-686-2266 North aver Insurance Agency, Inc. ind ®en e� MA. Foster Insurance Services, Inc. October 25,2006 Sturbridge Arms Condominiums 173 Main Street " X006 North Andover,MA 01845 .-NaOVER .1-kIV14w4G t1 PARTMr Dear Association Members: Please forgive our inappropriate method of contacting you but we do not have your legal contact information. As legally dictated, we have informed you officially via the town process that we are negotiating the razing and rebuilding of 163 Main Street. It is our intent to construct a first class colonial style office next to your properties. Some owners were there to meet us at the zoning board meeting on October 10, 2006 to get a feel for just what our project is all about. We had our plans available so those interested could get a preliminary view. We would like to offer an invitation for any others of your association and board members for a meeting to discuss our project. We certainly want to clean up and landscape the property to everyone's satisfaction, keeping your privacy in full consideration. The next zoning board meeting is scheduled for November 14, 2006. Can we meet to discuss prior to this date? We look forward to meeting and planning with our new neighbors. I have attached a business card for your convenience in reaching us. Sincerely, r Stephen M. Sullivan cc: North Andover Zoning Board ' North Andover Planning Board Attorney Domenic J. Scalise Michael J. Foster 9 Waverly Road 0 North Andover, MA 01845 0 Phone: 978-686-2266 0 Fax: 978-686-6410 Business 0 Home Auto 0 Life 0 Group 12 12 TOP Of PLATE O m m SECOND FLOOR FM rn 0 FIRST FLOOR ...........,� LOWER FLOOR_ ------------- ---------- PROPOSED EAST (MAIN STREET) ELEVATION I/8'= Y-0' TOWN OF NORTH ANDOVER PLANNING BOARD ENGINEERING REVIEW OF A SITE PLAN SPECIAL PERMIT FOR CONFORMANCE WIIH THE TOWN OF NORTH ANDOVER ZONING BYLAW Plan Iitle: Proposed Office Building at 163 Main Street VHB No..: 09280.25 Location: 163 Main St.,North Andover,MA 01845 Applicant: Stephen Sullivan&Michael Foster,9 Waverly Rd.,North Andover,MA 01845 Applicant's Engineer: Christiansen&Sergi, I60 Summer St.,Haverhill,MA 01830 Plan Date: Sept.27,2006 Review Date: November 1,2006 The plans were reviewed for conformance to the 1972 Town of North Andover Zoning Bylaw(last amended May 2005) The Applicant has submitted the following information for VHB's review: • Application for Site Plan Special Permit,with checklist,dated October 5,2006, • Site Plan for Proposed Office Building at 163 Main Street(1 sheet),dated October 27,2006, • Plan of Land(1 sheet),dated September 28,2006, • Building elevation plans(3 sheets),not dated, • Drainage Analysis dated October 2,2006 The following comments note non-conformance with specific sections of the Zoning Bylaw and general questions/comments on the proposed design and VHB's tecommendations/suggestions Town of'North Andover Zoning Bylaw 1. ('7.1) This section states that the minimum area for a lot located in the General Business Zoning District shall be 25,000 square feet,asset forth by the Summary of Dimensional Requirements(Table 2), The existing lot to be used as the location for the proposed office building has an area of approximately 11,750 square feet. The Applicant has filed an Application for Special Permit and is asking for a waiver from this requirement. 2 (7 2)The existing lot to be used as the location for the proposed site does not meet the minimum street frontage requirements as set forth in Summary of'Dimensional Requirements(Iable 2).. According to the Summary of'Dimensional Requirements,a lot located in the General Business Zoning District shalt have a minimum street frontage of 125 feet. The Applicant has not altered the dimensions of the existing lot,which has 50 feet of'street frontage,and has filed an Application for Special Permit for an exception to this requirement 3. ('72.2)Ihis section lists the criteria for exceptions from meeting the street frontage requirements as required by section,7 2 when an Application for Special Permit has been filed. The proposed site meets all of the criteria listed in this section except for requirement 7.2.2.a,which states that the area of the lot must exceed by three times the minimum lot area required for the zoning district The existing lot has an area of 11,750 square feet,which is less than the area required. The Applicant has filed an Application for Special Permit and should request a waiver from this section. 4.. (7 3) This section states that the minimum side setbacks for a lot located in the General Business Zoning District shall be 25 feet,as set forth by the Summary of Dimensional Requirements(Table 2).. Since the width of the existing lot is approximately 50 feet at the widest point,it is impossible for the 1 I:\09280 00\dots\memos\09?P025_163Main dot Applicant to meet the required 25 foot side setbacks the Applicant has provided setbacks of 5 feet and 16 feet for the east and west sides of the site respectively. the Applicant has filed an application with the Zoning Board of Appeals for Side Setback zoning relief' Has the Applicant verified with the Iown that no other variances/waivers are required? 5 (81.5.e_vi) A table showing zoning information has been provided,however it does not include all the information required in this section. the Applicant should revise. 6 (8.1.5.e.xvii) This section states that the identification of the proposed illumination,indicating the direction and the degree of illumination offered by the proposed lighting facilities be included in the Application. The Applicant should specify the direction and degree of illumination to be provided by the proposed lighting fixtures to ensure that the abutting properties are not affected by the proposed lights General Comments/Standard Engineering Practice '7. Although the existing roadway width for Main Street is not shown,it appears that a single unit design vehicle(small fire truck,ambulance or delivery truck)will only be able to make turns into and out of the existing drive with encroachment into oncoming traffic or onto the lawn/landscaped area. Has the Applicant considered revising the existing driveway opening? Drainage Comments 8. Has the Applicant verified that the proposed 8-inch PVC pipes can convey the flows from the catchment areas? Based on VHB's calculations,it appears that an 8-inch pipe at 0.5%slope may not have the capacity for the 10-and 100-year peak runoffs from area P1. The Applicant should verify and revise as necessary 9.. The Applicant has used a Iype IT rainfall distribution in the Hydrocad model.. Massachusetts is within a Type III area. The Applicant should revise. 10 The sum of the drainage areas for sub catchments P 1 and P2 is less than the drainage area used for the existing conditions The Applicant should verify that pre-and post-development total areas are consistent 11. The Applicant should provide soil boring data to verify that the bottom of the infiltration chambers will be at least 2 feet above seasonal high groundwater and to verify infiltration rate calculations 12. As currently designed,the only pre-treatment of'stormwater runoff before entering the Cultec system occurs in the deep sump catch basins. Has the Applicant considered additional pre-treatment,such as a water,quality unit,to avoid excessive build up of sediments in the Cultec system? 13. T here do not appear to be any measures in place to prevent parking lot flooding in the event the drainage system fails(also see above comment regarding sedimentation). It appears that any overflow from C132 would pool in the middle of'the parking lot and eventually reach the abutting MacGregor and Barnes lots. the Applicant should consider an emergency overflow outlet,such as a small Swale between the proposed building and the northerly lot line,or an overflow pipe to an existing drainage system on Main Street(if'one exists). It is recommended that the Applicant provide WRIITEN RESPONSES to the issues and comments contained herein. l Reviewed by: —C�� /^ Date: Courtney gulerad Civil Engineer—Highway and Municipal 2 TAM80 00\does\memos\0928025-163Main.doc Checked by: Date: Timothy clntosh,P E Project Manager—Highway and Municipal 3 I A09280 00\d«s\memos\092B025_I63Main.doc TOWN OF NORTH ANDOVER PLANNING BOARD RE0=1VED ENGINEERING REVIEW OF A SITE PLAN SPECIAL PERMIT FOR CONFORMANCE WITH THE p., V TOWN OF NORTH ANDOVER ZONING BYLAW ...,.AVER PLANNING DEPARTMENT Plan Title: Proposed Office:Building°at-163 Main Street VHB No.: 09280.25 Location: '`1:63 Main St.,North Andover,MA 01845 Applicant: Stephen Sullivan&Michael Foster, 9 Waverly Rd.,North Andover,MA 01845 Applicant's Engineer: Christiansen&Sergi, 160 Summer St.,Haverhill,MA 01830 Plan Date: Sept. 27,2006 Review Date: November 1,2006 2"d Review Date: November 22,2006 The Applicant has adequately addressed VHB's comments and no further engineering review is required at this time. Please refer to the final report below for additional details. The plans were reviewed for conformance to the 1972 Town of North Andover Zoning Bylaw(last amended May 2005). The Applicant has submitted the following information for VHB's second review: • Response to comments letter dated November 16,2006, • Site Plan for Proposed Office Building at 163 Main Street(1 sheet), dated October 27,2006, with revisions through November 16,2006, • Revised Drainage Analysis, including catchment area plans,dated November 16,2006. The following comments note non-conformance with specific sections of the Zoning Bylaw and general questions/comments on the proposed design and VHB's recommendations/suggestions. VHB's original comments are shown in normal font,with follow-up comments in bold. Town of North Andover Zoning Bylaw 1. (7.1)This section states that the minimum area for a lot located in the General Business Zoning District shall be 25,000 square feet, as set forth by the Summary of Dimensional Requirements(Table 2). The existing lot to be used as the location for the proposed office building has an area of approximately 11,750 square feet. The Applicant has filed an Application for Special Permit and is asking for a waiver from this requirement. No response required. 2. (7.2)The existing lot to be used as the location for the proposed site does not meet the minimum street frontage requirements as set forth in Summary of Dimensional Requirements(Table 2). According to the Summary of Dimensional Requirements,a lot located in the General Business Zoning District shall have a minimum street frontage of 125 feet. The Applicant has not altered the dimensions of the existing lot,which has 50 feet of street frontage,and has filed an Application for Special Permit for an exception to this requirement. No response required. RECEIVED NOV 2 i ilid;; NORTH AM)UVt.,� PLANNING DEPART lv1ENT 1 C:\DCKU\i E-I\in ippol it\LOCALS-1\Temp\0925025_163\tain_Eollowup.doc 3. (7.2.2)This section lists the criteria for exceptions from meeting the street frontage requirements as required by section 7.2 when an Application for Special Permit has been tiled. The proposed site meets all of the criteria listed in this section except for requirement 7.2.2.a,which states that the area of the lot must exceed by three times the minimum lot area required for the zoning district. The existing lot has an area of 11,750 square feet,which is less than the area required. The Applicant has filed an Application for Special Permit and should request a waiver from this section. The Applicant states in his response that this comment is to be addressed by his legal representative. VHB assumes no further review is required. 4. (7.3)This section states that the minimum side setbacks for a lot located in the General Business Zoning District shall be 25 feet,as set forth by the Summary of Dimensional Requirements(Table 2). Since the width of the existing lot is approximately 50 feet at the widest point,it is impossible for the Applicant to meet the required 25 foot side setbacks. The Applicant has provided setbacks of 5 feet and 16 feet for the east and west sides of the site respectively. The Applicant has filed an application with the Zoning Board of Appeals for Side Setback zoning relief. Has the Applicant verified with the Town that no other variances/waivers are required? The Applicant states in his response that this comment is to be addressed by his legal representative. VHB assumes no further review is required. 5. (8.3.5.e.vi) A table showing zoning information has been provided,however it does not include all the information required in this section. The Applicant should revise. Addressed. 6. (83.5.e.xvii) This section states that the identification of the proposed illumination,indicating the direction and the degree of illumination offered by the proposed lighting facilities be included in the Application. The Applicant should specify the direction and degree of illumination to be provided by the proposed lighting fixtures to ensure that the abutting properties are not affected by the proposed lights. Addressed. General Comments/Standard Enizineerin2 Practice 7. Although the existing roadway width for Main Street is not shown,it appears that a single unit design vehicle(small fire truck,ambulance or delivery truck)will only be able to make turns into and out of the existing drive with encroachment into oncoming traffic or onto the lawn/landscaped area. Has the Applicant considered revising the existing driveway opening? Addressed. Drainalze Comments 8. Has the Applicant verified that the proposed 8-inch PVC pipes can convey the flows from the catchment areas? Based on VHB's calculations,it appears that an 8-inch pipe at 0.5%slope may not have the capacity for the 10-and 100-year peak runoffs from area P 1. The Applicant should verify and revise as necessary. The Applicant states in his response that the capacities for the above-mentioned pipes have been verified and confirms that they have sufficient capacity to convey flows with minimal surcharging in the catch basins. No further review required. 9. The Applicant has used a Type II rainfall distribution in the Hydrocad model. Massachusetts is within a Type III area. The Applicant should revise. Addressed. 2 C:\DOCU bl E-1\in i ppol i t\LOCALS-1\Tem p\0925025_163A tai n_Pollow u p.doc 10. The sum of the drainage areas for sub catchments P 1 and P2 is less than the drainage area used for the existing conditions. The Applicant should verify that pre- and post-development total areas are consistent. Addressed. 11. The Applicant should provide soil boring data to verify that the bottom of the infiltration chambers will be at least 2 feet above seasonal high groundwater and to verify infiltration rate calculations. The Applicant states in his response that once testing is performed,the required 2-foot separation will be confirmed and that any revisions to the design will be submitted to the Board for review. No further review required at this time,however the Board may consider making this 2-foot separation a condition of approval for this Special Permit. 12. As currently designed,the only pre-treatment of stormwater runoff before entering the Cultec system occurs in the deep sump catch basins. Has the Applicant considered additional pre-treatment,such as a water quality unit,to avoid excessive build up of sediments in the Cultec system? Addressed. 13. There do not appear to be any measures in place to prevent parking lot flooding in the event the drainage system fails(also see above comment regarding sedimentation). It appears that any overflow from C132 would pool in the middle of the parking lot and eventually reach the abutting MacGregor and Barnes lots. The Applicant should consider an emergency overflow outlet,such as a small swale between the proposed building and the northerly lot line,or an overflow pipe to an existing drainage system on Main Street(if one exists). Addressed. It is recommended that the Applicant provide WRITTEN RESPONSES to the issues and comments contained herein. Reviewed by: Date: Darryl Gallant Civil Engineer—Highway and Municipal Checked by: Date: Timothy B. McIntosh,P. E. Project Manager—Highway and Municipal 3 C:\DOCUAI E—I\m ippol it\LOCALS-I\Tent p\0928025_163 N Iai n_Fol lore u p.cioc TOWN OF NORTH ANDOVER MASSACHUSETTS OLD CENTER HISTORIC DISTRICT COMMISSION Stephen Sullivan 9 Waverly Road North Andover, MA 01845 RE: 163 Main Street North Andover TO WHOM IT MIGHT CONCERN: Please be advised that the property at,163 Main Street is not in the historic district. It therefore does not need approval ftom the Old Center Historical District Commission. Any questions please call me at 978 685 5000. Sincerely, George H. Schruender, Jr. Chairman NA Old Center Historic District Commission f/ NORTH ANDOVER " '�' x•F'r f ' HISTORICAL, COMMISSION North Andover Town Planning Board November 28,2006, 120 Main Street North Andover,MA 01845 Dear Board Members, .Mr. Stephen Sullivan, who recently bought the property at 163 Main Street, North Andover, contacted the North Andover Historical Commission regarding the status of that property. He asked the Commission to determine whether the property at 163 Main Street had,any local/state preservation restrictions on the property. Through research the Historical Commission has-determined that the property at 163 Main Street, North Andover is not listed in any historical district.and has no local or state preservation restriction agreements attached to the property.. If the Planning Board has any questions or needs further clarification, please contact Kathleen Szyska, President, North Andover Historical Commission, at 978-686-4035 (day)or 918-683-553.6(night). Sincerely; K een Szyska. P sident,North Andover Historical Commission DOMENIC J. SCALISE; 5 /E 0 ATTORNEY AT LAV11°;°P;"r° Y 89 MAIN STREET NORTH ANDOVER, MASSACHIMJ40� � 1�9� TELEPHONE (978) 682-4153 FAX (978) 794-2088 EMAIL djs @djscalisexorq 0[1 k `� € E'o November 29, 2006 Town of North Andover Planning Department 1600 Osgood Street North Andover, MA 10845 ATTN: Mary Ippolito RE: Applicant-Foster& Sullivan Site Plan Special Permit Proposed Office Building— 163 Main St Dear Mary: Concerning the above captioned matter which was commenced at the Planning Board meeting on November 21, 2006, and continued to the next scheduled public meeting on December 5, 2006,request is hereby made that the matter be continued until the following meeting of December 19, 2006. The reason for this request for continuance is that I will be out of the office from December lst through December 6th and unavailable for the December 5 meeting. In the interim, my clients continue to respond to the issues raised at the last Planning Board Meeting. Thanking you in advance for your cooperation, I remain Vey truly yours, Domenic . Scalise DJs/t 49CEIVED )VIM)&Tj%*QQ*-U' RECEIVED OLU ', 9 06 NOR i'-i,-,­,,,ER December 11, 2006 PLANNING DEPARTMENT I, David Macgregor owner of 161 Main Street grant permission to Stephen Sullivan & Michael Foster owners of 163 Main Street to do the following: -Remove entire cluster of trees located on the property line of 161&163 Main Street . Trees are located directly to the front and left of the entrance to 161 Main and to the right rear corner of 163 Main Street. -Erect a 6 foot white vinyl fence topped with a 1 foot decorative lattice work along the property line between 161 & 163 Main Street . I grant permission to the tree and fence contractors access to my property for the safe removal of the trees and installation of the fence. Stephen Sullivan & Michael Foster agree to clean all tree debris from 161 Main Street and to restore any disturbed soil. Agreed to and signed by: Michael J. Foster Stephen M. Sullivan David Macgregor(, RECEIVED Romasar, LLC NOR i ri r-\1,4uOVER Building Contractors PLANNING DEPARTMENT 2 Red Oak Drive, Unit D Plaistow, NH 03865 p 603.382.5114 f 603.382.5118 February 20,2007 North Andover Planning Department: As per your Order of Conditions regarding the site at 163 Main Street,North Andover you are being notified that tree removal will commence on or after February 26th 2007. If you have any questions please contact: Robert Cunningham, General Contractor for Michael Foster and Steven Sullivan Romasar,LLC 2 Red Oak Drive,Unit D Plaistow, NH 03865 c 978.852.7867