Loading...
HomeMy WebLinkAboutMiscellaneous - Exception (454)SEWAGE PUMP STATION DESIGN COMPUTATIONS -For: Michael & Elaine Morgillo ,Date: 02/28/2002 TA: DESIGN FLOW 440 SOIL CLASS II PERC RATE 20 FORCE MAIN DIA. 2 HAZEN WILLIAMS C -VALUE 150 SUBMERSIBLE PUMP SPECIFICATIONS: MANUFACTURER: MODEL #: HORSEPOWER: IMPELLER DIAMETER: SOLIDS HANDLING: Peabody -Barnes SE411 0.4 5.44" 2" PUMP CHAMBER SPECIFICATIONS: STORAGE Job No. 9302 Calculated by: CRO Checked bv: VVT Gal/Day Min/Inch SDR 21 PVC DISCHARGE: SPEED: VOLTAGE: PHASE: PRIMARY 440.0 gallons RESERVE 440.0 gallons VOL. IN PIPE RUN 15.5 gallons TOTAL 895.5 gallons DIMENSIONS 1500 (H-10/Mon.) Gallon Pump Chamber LENGTH* 10.16 feet WIDTH* 5.00 feet DEPTH* 4.33 feet *INSIDE DIMENSIONS ELEVATIONS INLET INVERT 89.80 feet At -ARM 88.2 feet ON 87.7 feet OFF 86.5 feet SUMP 85.5 feet CALCULATE STATIC HEAD: DISCHARGE ELEV. 101.07 feet PUMP OFF ELEV. 86.5 feet TOTAL STATIC HEAD 14.6 feet 2 " NPT 1750 RPM 115V SINGLE Page 9302SDSrev.xis